1.0INTRODUCTION

You have made an excellent choice in selecting the Dometic Absorption Refrigerator. We are sure that you will be fully satisfied with your new appliance in all respects.

The appliance, which works silently, meets high quality standards and guarantees the efficient utilisation of resources and energy throughout its entire life cycle, during manufacture, in use and when being disposed of.

Before you start to use the appliance, please read the installation and operating instructions carefully.

The refrigerator is designed for installation in leisure vehicles such as caravans or motorcaravans. The appliance has been certified for this application in accordance with EU Gas Directive 90/396/EEC.

2.0FOR YOUR SAFETY

2.1Warning and safety notices

Warning Attention

￿ Never use a naked flame to check the appliance for leaks.

￿Protect children!

When disposing of the refrigerator, remove all refrigerator doors and leave the storage rack in the refrigerator. This will prevent accidental locking in or suffocation.

￿If you smell gas:

-close the locking tap of the gas supply and the valve on the cylinder.

-open the windows and leave the room.

-do not switch on anything electrical.

-extinguish naked flames.

￿Never open the cooling unit; it is under high pressure.

￿Work on the gas, flue system and electrical components must only be carried out by qualified service personnel.

￿It is imperative that the operating pressure should correspond to the data given on the model plate of the appliance.

￿Compare the operating pressure data given on the model plate with the data on the pressure monitor of the liquid gas cylinder.

￿Gas operation of the appliance is not permitted while travelling on ferries.

￿Covers ensure electrical safety and must only be removed using a tool.

￿The appliance must not be exposed to rain.

￿The refrigerator is not suitable for the proper storage of medications.

2.2Coolant

Ammonia is used as a coolant.

This is a natural compound also used in household cleaning agents (1 litre of Salmiak cleaner contains up to 200g of ammonia - about twice as much as is used in the refrigerator). Sodium chromate is used for corrosion protection (1.8% of the solvent).

In the event of leakage (easily identifiable from the unpleasant odour):

￿Switch off the appliance.

￿Air the room thoroughly.

￿Inform the authorised Customer Service department.

4

Image 4
Contents Manual Safety instructions Table of Contents Introduction CoolantCleaning Damage in transitUsing the refrigerator ControlsManual energy selection MES RM 76x1 L Automatic and manual energy selection AES RM 76x5 LElectrical operation Mains power12V operation DC AUTO-operation Gas operationExplanations Operation Gas faults RM 76x1 and RMGas operation Temperature setting cooling compartment Storing foodFrame heating Additional functions RM 76x5 onlyMaking ice cubes DefrostingPositioning the storage rack DismantlingDoor locking Switching offWinter operation Interior light Changing the decor panelChanging the doorhang Troubleshooting Maintenance Product liabilityEnvironmental hints DisposalTechnical data Declaration of conformitySide installation InstallationRear installation Draught-free installation CommentInstallation of lower and upper ventila- tion grilles L500 Ventilation and extractionInstalling the ventilation system 500Installation recess Securing the refrigeratorConnections for gas / electrical installation Gas installationGas-pressure Power line connection Electrical installationBattery connection Retrofitting From the manual energy mode to the automatic energy modeSolar control input S+ Wiring diagram Wiring diagram for RM 76x1 LWiring diagram for RM 76x5 L Page Dometic GmbH Der Steinwiese Siegen