6.0INSTALLATION GUIDE

On installation of the appliance, the technical and administrative regulations of the country in which the vehicle will first be used must be adhered to. Otherwise the refrigerator must be installed as described in these instructions. In some OEM appli- cations it may not be possible for these instructions to be followed exactly. In this case an authorised Dometic representative may issue supplementary instruction

In Europe, for example, gas appliances, cable laying, installation of gas cylinders, as well as approval and checking for leaks must comply with EN 1949 for liquid gas units in vehicles.

6.1Installation

The appliance and its fume extraction shall be installed in such a way as to be acces- sible for servicing at all times and must be capable of easy removal and installation. The appliance may only be installed by authorised personnel.

Installation and connection of the appliance must comply with the latest technical regulations, as follows:

￿The electrical installation must comply with national regulations.

￿Technical regulations EN 60335-1, EN 60335-2-24, EN 1648-1 , EN 1648-2

￿The gas installation must comply with national regulations.

￿Technical regulations EN 1949

￿Technical regulations EN 732

￿Local and building control department requirements

￿The appliance shall be installed in such a way that it is shielded from excessive heat radiation.

Excessive heat impairs performance and raises the energy consumption of the refrigerator.

Any installation that is not carried out by qualified persons will jeo- pardize the manufacturer's guarantee.

6.1.1Side installation

If the appliance is installed on the same side of the vehicle as the entrance

door, it is desirable that the door does not cover the refrigerator’s vents. If this cannot be avoided there must be a gap of at least 25mm between the door and the vents.

6.1.2Rear installation

If the refrigerator is mounted at the rear of the vehicle you must ensure the lower grille is not covered by the bumper or rear lights. This would be prevent the air from circula- ting properly and cause problems in warm weather.

Air vent grille not

blocked: OK!

An installation that is not carried out by qualified persons causes a reduction in the cooling capacity and will jeopardize the manufactur- er's guarantee.

18

Image 18
Contents Manual Safety instructions Table of Contents Introduction CoolantCleaning Damage in transitManual energy selection MES RM 76x1 L Using the refrigeratorControls Automatic and manual energy selection AES RM 76x5 LMains power Electrical operation12V operation DC Gas operation AUTO-operationExplanations Gas faults RM 76x1 and RM OperationGas operation Frame heating Temperature setting cooling compartmentStoring food Additional functions RM 76x5 onlyPositioning the storage rack Making ice cubesDefrosting DismantlingSwitching off Door lockingWinter operation Interior light Changing the decor panelChanging the doorhang Troubleshooting Environmental hints MaintenanceProduct liability DisposalTechnical data Declaration of conformityInstallation Side installationRear installation Draught-free installation CommentInstallation of lower and upper ventila- tion grilles L500 Ventilation and extractionInstalling the ventilation system 500Installation recess Securing the refrigeratorConnections for gas / electrical installation Gas installationGas-pressure Electrical installation Power line connectionBattery connection From the manual energy mode to the automatic energy mode RetrofittingSolar control input S+ Wiring diagram Wiring diagram for RM 76x1 LWiring diagram for RM 76x5 L Page Dometic GmbH Der Steinwiese Siegen