PRODUCT DATA SHEETS
Base Grille Water Filtration System
Model
Model
Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine, Taste and Odor, Particulate Class II*; and against ANSI/NSF Standard 53 for the reduction of Lead.
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42/53.
Substance Reduction | NSF Reduction | Average | Influent Challenge | Maximum | Average | Minimum % | Average % | NSF Test |
Aesthetic Effects | Requirements | Influent | Concentration | Effluent | Effluent | Reduction | Reduction | Number |
|
|
|
|
|
|
|
|
|
Chlorine Taste/Odor | ≥50% | 2.0 mg/L | 2.0 mg/L ± 10% | 0.03 mg/L | 0.025 mg/L | 98.5% | 99.0% | |
Particulate Class II* | ≥85% | 833,333/mL | At least 10,000 | 100,000/mL** | 40,667/mL | 88.0% | 95.1% | |
|
|
| particles/mL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Contaminant | NSF Reduction | Average | Influent Challenge Maximum | Average | Minimum % | Average % | NSF Test | |
Reduction | Requirements | Influent | Concentration | Effluent | Effluent | Reduction | Reduction | Number |
|
|
|
|
|
|
|
|
|
Lead: @ pH 6.5 | 0.01mg/L | 0.16 mg/L*** | 0.15 mg/L ± 10% | 0.001 mg/L | 0.001 mg/L | 99.35% | 99.35% | |
Lead: @ pH 8.5 | 0.01mg/L | 0.15 mg/L*** | 0.15 mg/L ± 10% | 0.001 mg/L | 0.001 mg/L | 99.31% | 99.31% | |
|
|
|
|
|
|
|
|
|
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F (17.2°C).
■It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.
■Model
■Model
Part #4396508. 2003 suggested retail price of $32.99 U.S.A./ $49.95 Canada. Prices are subject to change without notice.
■The product is for cold water use only.
■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
■Refer to the front cover or “Assistance or Service” section for the Manufacturer’s name, address and telephone number.
■Refer to the “Warranty” section for the Manufacturer’s limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply | City or Well |
Water Pressure | 30 - 120 psi (207 - 827 kPa) |
Water Temperature | 33° - 100°F (0.6° - 37.8° C) |
Service Flow Rate | 0.5 gpm (1.9 L/min.) @ 60 psi. |
|
|
*Class II particle size: >1 to <5
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
***These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.