Bosch Appliances DKE94 Installation Procedure, Power Requirements, Unpack Hood, Prepare Ductwork

Page 6

Power Requirements

of weight the wall must support. Note: At least one screw must be installed through a stud.

Table 1: Minimum Weight Requirements

Size

With Recirculation Kit

Without Recirculation Kit

 

 

 

30” (760 mm)

140 lbs (63.5 kg)

126 lbs (57.1 kg)

 

 

 

36” (900 mm)

155.5 lbs (70.5 kg)

142 lbs (64.5 kg)

 

 

 

Electrical Specifications: 120V AC, 60Hz. 15A Branch Circuit

Installation Procedure

 

 

WARNING: To avoid electrical shock hazard, before installing,

 

 

switch power off at the service panel and lock the panel to prevent the

 

 

power from being switched on accidentally.

1)

Unpack Hood

Pull hood from outer packaging. Remove and discard all packaging materials.

 

 

Remove filter and set aside (See Use and Care manual for removal instructions).

2)

Prepare Ductwork

Install one-way damper so that the flap opens up. Press damper down into the

 

 

blower outlet until it is snug. Note: verify that the flap opens up (toward the ceiling)

 

 

before continuing. See “Prepare Ductwork” on page 4. If necessary, install transi-

 

 

tion, thermal break and additional backdraft damper.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2: Prepare Ductwork

3) Prepare Wall

See “General Information” on page 2 for recommended installation height and

 

“Mounting Requirements” on page 3 for information on wall requirements.

 

Once the preferred height is determined, draw a line at the vertical centerline of

 

the cooking appliance.

 

Use the installation template to locate and mark the screw holes. Drill 1/4” (6 mm)

 

pilot holes (4 holes for hood screws and 2 holes for chimney screws). Install plugs

 

in screw holes so that they are flush with the wall.Install two screws in top hood

 

screw holes. Leave about 3/8” (6 mm) of each screw exposed.

English 4

Image 6
Contents Bosch ventilation installation manual DKE94 Questions? Safety Important Safety InstructionsEquipment and Usage Safety Requirements Tools and Parts Needed InstallationBefore You Begin Parts IncludedDucting Recommenda- tions Overall Dimensions Overall DimensionsUnpack Hood Installation ProcedurePower Requirements Prepare DuctworkAttach Chimney Mounting Bracket Attach Mounting Brackets EnglishConnect to Ductwork Install ChimneyHang the Hood Connect ElectricService Product Data PlateFinal Steps Data Plate Location Page Nous attendons de vos nouvelles Sécurité Instructions de sécurité importantesExigences de sécurité pour l’équipement et l’utilisation Avant de commencer Outils et pièces nécessaires Pièces comprises GénéralitésRecommandation de conduits Dimensions hors tout Exigences de fixationDéballer la hotte Marche à suivre d’installationExigences électriques Préparation de conduitInstallation de la fixation de cheminée Installation des fixationsInstaller la cheminée Connexion au conduitConnexion électrique Avant d’effectuer un appel de service Plaque signalétiqueÉtapes finales Emplacement de la plaque signalétique Page ¿Preguntas? Seguridad Requerimientos de seguridad del equipo y su usoInstalación Antes de comenzarPartes incluidas Información general Recomendaciones para los ductos Dimensiones generales Requerimientos de montajeDesempacar la campana Procedimiento de instalaciónRequerimientos eléctricos Preparar los ductosFijar el soporte de montaje del tiro chimenea Colgar la campanaConectar los ductos Conexión eléctricaInstalar el tiro chimenea Servicio Antes de solicitar servicioPasos finales Figura 8 Ubicación de la placa de información