PREPARE THE HOOD
NON - DUCTED CONFIGURATION
Note: The following materials must be purchased separately for
•Non - Ducted Recirculation Kit, Model NDK7388
•
•
5” diameter expandable / flexible aluminum duct.
1/16” diameter twist drill.
CAUTION: Do not use plastic or rigid metal ducting.
1.Remove the tape on the electrical system plate; place the electrical system plate on the hood (use a protection). Fig. 8
2.Discard discharge collar and damper supplied with the hood. Install the 5” to 6” adapter supplied with the
3.Measure the distance “A”.
4.Attach aluminum flexible duct to the 5” adapter. Tape all joints with duct tape. Fig. 9.
5.Assemble the recirculation plenum to the
6.Drill three (3) 1/16” diameter equally spaced holes through the duct and duct connector of the recirculation plenum. Fig. 9.
7.Secure duct to the plenum’s connector with (3) sheet metal screws (not included). Tape all joints with duct tape. Fig. 9.
ELECTRICAL
SYSTEM
PLATE
PROTECTION |
|
| |
| FIG. 8 | ||
|
|
| |
|
|
|
|
PLENUM |
|
| |
(3) SCREWS |
|
| |
5” ALUMINUM |
|
|
|
|
|
| |
FLEX DUCT |
|
|
5” 6” ADAPTER | A |
|
BLOWER
COLLAR
FIG. 9
- 9 -