INSTALLATION AND OPERATIONAL CHECKS

After installation, check for gas soundness. The supply pressure can be checked at the grill injector. Access to the injector is by first removing the baffle at the front of the grill fastened by two screws. Then remove the fastening screw on the right hand side of the burner and slide the burner off the injector. Ensure that the grill burner is correctly located under the fixing screw on reassembly.

Fit the hotplate burner caps and bodies and pan supports. Referring to the instructions for use where necessary;

1.Check that the hotplate and grill burners ignite correctly and burn with a steady flame. Check for a steady flame on the low setting.

2.Check that with the oven set to mark 9, the burner ignites at low rate,

and then increases to full rate within 60 seconds. Leave the oven full on with the door closed for 10 minutes, and check that when the control is turned to the ‘E’ setting that the flame reduces.

3.Check the operation of the oven timer and oven light(s).

Instruct the user on operation of the cooker.

32

Image 32
Contents Windsor Mk2 Contents Features IntroductionFor Your Safety AlwaysFor Your Safety Oven Timer Operation Guidance on Automatic CookingKnow Your Timer ClockfaceSetting the Time of DAY Auto Cooking Programmes Step Other Notes on Timer Operation Hotplate To USE the HotplateSafety Requirements for Deep FAT Frying HOW to Deal with a FAT FireRelighting the Burner GrillTo USE the Grill Oven To USE the OvenCold Start Cooking Roasting of Large PoultryStorage and RE-HEATING of Food ‘COOK CHILL’ DishesOven Cooking Chart Meat and PoultryYeast Mixtures ‘E’ Setting Using the ‘E’ Setting for Slow CookingReplacement of Oven Light Bulb Care and CleaningOven Heat Clean Linings Cooker Finish Cleaning Method Vitreous EnamelHotplate Side Opening Doors Drop Down DoorsProblem Check Something Wrong With Your CookerSomething Wrong Installation Instructions GAS Safety Installation & USE RegulationsLocation Provision for VentilationNatural GAS Technical Data DimensionsGeneral Space for Fixing Cooker HoodsViewed from Rear Stability Bracket Unpacking the CookerLevelling Connecting to GAS Supply Electrical Connection Connect to a 230-240V A.C. Supply onlyInstallation and Operational Checks Gas Appliances 90/396/EEC Page Page Key Contacts