SAFETY REQUIREMENTS FOR DEEP FAT FRYING

1.Never fill chip pans more than one third full with oil or fat.

2.Never leave oil or fat unattended during the heating or cooling period.

3.Never heat fat or fry with a lid on the pan.

4.Always dry food thoroughly before frying, and lower it slowly into the hot oil or fat. Frozen foods in particular will cause frothing and spitting if added too quickly.

5.Always keep the outside of the pan clean and free from streaks of oil or fat.

HOW TO DEAL WITH A FAT FIRE

1.Do not move the pan.

2.Turn off the hotplate burners.

3.Smother the flames with a fire blanket or damp cloth to extinguish the fire. Do not use water or a fire extinguisher as the force of it may spread the burning fat or oil over the edge of the pan.

4.Leave the pan for at least 60 minutes before moving it.

13

Image 13
Contents Windsor Mk2 Contents Introduction FeaturesAlways For Your SafetyFor Your Safety Guidance on Automatic Cooking Oven Timer OperationClockface Know Your TimerSetting the Time of DAY Auto Cooking Programmes Step Other Notes on Timer Operation To USE the Hotplate HotplateHOW to Deal with a FAT Fire Safety Requirements for Deep FAT FryingTo USE the Grill GrillRelighting the Burner To USE the Oven OvenRoasting of Large Poultry Cold Start CookingStorage and RE-HEATING of Food ‘COOK CHILL’ DishesMeat and Poultry Oven Cooking ChartYeast Mixtures Using the ‘E’ Setting for Slow Cooking ‘E’ SettingOven Heat Clean Linings Care and CleaningReplacement of Oven Light Bulb Vitreous Enamel Cooker Finish Cleaning MethodHotplate Drop Down Doors Side Opening DoorsSomething Wrong With Your Cooker Problem CheckSomething Wrong GAS Safety Installation & USE Regulations Installation InstructionsLocation Provision for VentilationGeneral Technical Data DimensionsNatural GAS Cooker Hoods Space for FixingLevelling Unpacking the CookerViewed from Rear Stability Bracket Connecting to GAS Supply Connect to a 230-240V A.C. Supply only Electrical ConnectionInstallation and Operational Checks Gas Appliances 90/396/EEC Page Page Key Contacts