Blodgett KLT-G Series manual Adding Water Low water light comes on, For Reference

Page 24

6.0SERVICE (Continued)

ADDING WATER (Low water light comes on)

It may be necessary to replenish water in the jacket when the low water indicator comes on. Do so as follows:

1.Unit should be completely cold and off.

2.Lift handle of pressure relief valve to release vacuum in kettle.

3.Remove relief valve and attach a 3/4" NPT elbow pointing upward.

4.Using pure distilled water only, pour the water into the open end of elbow (a funnel will be helpful). Water will enter kettle slowly, as air must escape through the same hole. Water should be added until water level at the sight glass is halfway between the minimum and maximum levels.

5.When sufficient water has been added, remove elbow and replace pressure relief valve. Be sure to seal threads with a pipe joint compound suitable for steam at 50 psi.

6.Vacuum must be re-established (See Re-establishing Vacuum).

FOR REFERENCE:

The total amount of distilled water to be added when low level pilot is illuminated:

KLT-20G

- 169 fl. oz. (5 L)

KLT-40G

-

270 fl. oz. (8 L)

KLT-60G

-

372 fl. oz. (11 L)

24

Image 24
Contents Important Notes for Installation and Operation KLT-G SeriesPage Table of Contents Description Service Connections Model GAS SupplyInstallation Installation Codes and Standards Sides Inches BackFloors NON-COMBUSTIBLE Installation To InstallGAS Connection Water Connection Electrical ConnectionPerformance Check Operation GAS Control InstructionsLighting Daily Shutdown Complete ShutdownFront Panel Controls Power Switch Green Ignition LightRED Cooking Light Amber LOW Water LightDial Setting ThermostatPressure Gauge Sight GlassPressure Relief Valve Daily OperationEND USE Tips GAS Saving Tips Cleaning Instructions Cleaning Instructions DRAW-OFF Valve CleaningDairy DRAW-OFF Valve Cleaning What to do if Surface Rust Appears Stainless SteelCleaning Instructions Maintenance DailyMonthly Twice a Year minimumService General AdjustmentsManifold Pressure Pressure Switch To Adjust Pressure Switch Adding Water Low water light comes on For ReferenceRE-ESTABLISHING Vacuum Troubleshooting Problem AdjustmentsLook for Shutter Settings Kettle Size/Gas Type Natural PropaneShutter setting at Material Safety Data Sheet Preparation Information Material Safety Data SheetChemical Product and Company Identification ProductHazards Identification Emergency Overview Product DOWFROST* HD Heat Transfer FLUID, DyedFirst AID Fire Fighting Measures Flammable PropertiesFlammability Limits Material Safety Data Sheet Handling and Storage Exposure CONTROLS/PERSONAL ProtectionPersonal Protective Equipment Physical and Chemical Properties Stability and ReactivityMutagenicity Environmental FateTransport Information Regulations Toxic Substances Control ACT TscaChemical Name CAS Number List PA1Canadian Regulations Canadian Environmental Protection ACT CepaOther Information