Flame burns only about 6 seconds and shuts off.

SFlame rod or flame ground mislocated. S Defective flame rod wire.

S Defective ignition module.

S Burner rate set too high. Ensure that manifold pressure is set per rating plate and that correct orifice size installed (See table page 21).

S Burner getting too much air. Reduce air shutter opening (not below 1.0).

Short flame.

S

Wrong size orifice. (See table on page

 

21).

 

 

 

S

Low gas pressure.

 

S Air shutter adjustment. (See table, shutter

 

 

setting)

 

S Main manual valve partially closed.

Long hazy flame.

S

Wrong size orifice.

S

High gas pressure.

 

 

S Dirty blower wheel or intake.

 

S

Air shutter adjustments.

Gas fails to shut off.

S Dirt on valve seat.

S

Defective main valve.

 

NOTE: Loose, broken or grounded wiring may cause many of the symptoms listed. Check all wiring and make sure it is intact.

SHUTTER SETTINGS

Kettle Size/Gas Type

Natural

Propane

20

Gallon (80,000 BTU/HR)

1.5

2.0

30/40 Gallon (100,000 BTU/HR)

1.5

2.0

60

Gallon (120,000 BTU/HR)

2.0

3.0

 

 

 

 

Shutter setting is on the fan intake. Adjust the shutter per the table above by loosening the screw on the shutter closest to the stamped numbers and turning the shuttle disc until the screw points to the correct setting. Tighten screw when adjustment is complete. Figure 1 below shows a shutter setting of 2.0. Look at the flame through the plastic window in the rear of the burner. It should be mostly blue with slight bits of orange flame on natural gas. On propane, flame will be more orange in color. Using a portable gas analyzer, shutter settings can be adjusted to yield between 5.0-8.0 CO2. Air free CO should read below 100ppm. Once the burner is set up and operating properly, secure all wires and replace all covers.

27

Image 27
Contents KLT-G Series Important Notes for Installation and OperationPage Table of Contents Description Model GAS Supply Service ConnectionsInstallation Installation Codes and Standards Sides Inches BackFloors NON-COMBUSTIBLE To Install InstallationGAS Connection Electrical Connection Water ConnectionPerformance Check Operation GAS Control InstructionsLighting Complete Shutdown Daily ShutdownAmber LOW Water Light Front Panel Controls Power SwitchGreen Ignition Light RED Cooking LightSight Glass Dial SettingThermostat Pressure GaugePressure Relief Valve Daily OperationEND USE Tips GAS Saving Tips Cleaning Instructions Cleaning Instructions DRAW-OFF Valve CleaningDairy DRAW-OFF Valve Cleaning Stainless Steel What to do if Surface Rust AppearsCleaning Instructions Twice a Year minimum MaintenanceDaily MonthlyService General AdjustmentsManifold Pressure Pressure Switch To Adjust Pressure Switch For Reference Adding Water Low water light comes onRE-ESTABLISHING Vacuum Troubleshooting Problem AdjustmentsLook for Kettle Size/Gas Type Natural Propane Shutter SettingsShutter setting at Product Material Safety Data Sheet Preparation InformationMaterial Safety Data Sheet Chemical Product and Company IdentificationProduct DOWFROST* HD Heat Transfer FLUID, Dyed Hazards Identification Emergency OverviewFirst AID Fire Fighting Measures Flammable PropertiesFlammability Limits Material Safety Data Sheet Handling and Storage Exposure CONTROLS/PERSONAL ProtectionPersonal Protective Equipment Stability and Reactivity Physical and Chemical PropertiesEnvironmental Fate MutagenicityTransport Information PA1 RegulationsToxic Substances Control ACT Tsca Chemical Name CAS Number ListCanadian Regulations Canadian Environmental Protection ACT CepaOther Information