Chapter 7
Display | Description | Unit |
XX | XX: Ink color | (x 1,000,000) dots |
| Cumulative dot counts of each colors |
|
|
|
|
TTL | Total cumulative dot counts of each colors | (x 1,000,000) dots |
|
|
|
18) PARTS CNT. : Counter related to consumable parts
|
|
|
| |
|
|
|
| |
Display |
| Description | Unit | |
|
|
|
|
|
COUNTER x |
|
| x: A to V | Day(s) |
|
|
| (For detail, refer to "Maintenance and Inspection" > "Consumable Parts") |
|
|
|
| Display the status and the days passed since the counter resetting. |
|
|
|
| - Status |
|
|
|
| OK: Use rate (until part replacement) of all consumable parts included in each unit are below 90%. |
|
|
|
| W1: Use rate (until part replacement) of either of the consumable parts included in each unit has reached 90% or |
|
|
|
| more. |
|
|
|
| W2: Use rate (until part replacement) of either of the consumable parts included in each unit has reached 100%, but |
|
|
|
| no need to stop the printer. |
|
|
|
| E : Use rate (until part replacement) of either of the consumable parts included in each unit has reached 100%, and |
|
|
|
| the printer needs to be stopped. |
|
|
|
|
|
|
| PARTS yy | 1: | yy: A to V1 |
|
|
|
| (For detail, refer to "Maintenance and Inspection" > "Consumable Parts") |
|
|
|
| Counter of the consumable part (current) |
|
|
|
|
|
|
|
| 2: | Life of the consumable part |
|
|
|
|
|
|
|
| 3: | Use rate until part replacement | % |
|
|
|
|
|
|
| 4: | Counter of the consumable part (accumulate) |
|
|
|
|
|
|
e) SETTING
Make various settings.
1) Pth
Turn on or off the head pulse rank control function. Default: OFF
2) RTC
Set RTC (real time clock) after replacing the lithium battery on the main controller PCB.
Display |
| Description |
DATE | yyyy/mm/dd | Set date |
|
|
|
TIME | hh:mm | Set time |
|
|
|
f) INITIALIZE
Clear the [DISPLAY] histories, [ADJUST] settings, [COUNTER] values, and other parameters.
Display | Description | |
WARNING | Initialize the history of WARNING. | |
|
| (All displayed contents of [DISPLAY] > [WARNING] will be initialized.) |
|
| |
ERROR | Initialize the history of ERROR. | |
|
| (All displayed contents of [DISPLAY] > [ERROR] will be initialized.) |
|
| |
ADJUST | Initialize the value of band adjustment (by user) and head adjustment. | |
|
| The automatically adjusted value will not be initialized. |
|
| |
Initialize the remaining capacity (%) of the maitenance cartridge. | ||
|
| (Clear [COUNTER] > [PRINTER] > |
|
| |
CARRIAGE | Initialize the cumulative time of carriage driving. | |
|
| (Clear [COUNTER] > [CARRIAGE] > [DRIVE]) |
|
| |
PURGE | Initialize the counter related to purge unit. | |
|
| (Clear [COUNTER] > [PURGE]) |
|
| |
| Initialize the consumption amount of ink. | |
|
| (Clear [COUNTER] > |
|
| |
| Initialize the cutter unit replacement frequency. | |
|
| (Clear [COUNTER] > [EXCHANGE] > [CUTTER EXC.], and count up [COUNTER] > [CLEAR] > |
|
| EXC.]) |
|
| |
| Initialize the maintenance cartridge replacement frequency. | |
|
| (Clear [COUNTER] > [EXCHANGE] > [MTC EXC.], and count up [COUNTER] > [CLEAR] > |
|
| |
| Initialize the printhead R replacement frequency. | |
|
| (Clear [COUNTER] > [EXCHANGE] > [HEAD R EXC.], and count up [COUNTER] > [CLEAR] > |
|
| |
| Initialize the printhead L replacement frequency. | |
|
| (Clear [COUNTER] > [EXCHANGE] > [HEAD L EXC.], and count up [COUNTER] > [CLEAR] > |
|
|
|
| PARTS xx | xx: A to V1 |
|
| (For details, refer to "Maintenance and Inspection" > "Consumable Parts") |
|
| Initialize the consumable part replacement frequency. |
|
| (Clear [COUNTER] > [EXCHANGE] > [UNIT x EXC], and count up [COUNTER] > [CLEAR] > |
|
|
|