Canon 2163B002 service manual Media take-up Unit, Humidity sensor, Media take-up on/off sensor

Models: 2163B002

1 200
Download 200 pages 25.92 Kb
Page 67
Image 67

Chapter 2

Humidity sensor

The humidity sensor detects the temperature and relative humidity around the printer to implement head height adjustment, maintenance jet control, waste ink evap- oration calculation and suction fan control on the basis of the temperature and relative humidity thus measured.

2.5.6 Media take-up Unit

Media take-up on/off sensor

OFF

ON

Media take-up

paper detection sensor

F-2-34

Media take-up on/off sensor

The photointerrupter-based media take-up on/off sensor detects the switch status of the media take-up unit.

When the media take-up switch is set to ON, the sensor arm transmits the sensor light, power-on the media take-up unit. When the media take-up switch is set to OFF, the sensor arm shields the sensor light, shutting down the media take-up unit.

Media take-up paper detection sensor

When the sensor light is shielded by a loop of printed paper, the media take-up motor rotates to take up the paper.

2-25