2.2 WALL EXHAUST FAN:
The exhaust fan should be installed at least two feet above the vent opening at the top of the unit.
2.3 CLEARANCES:
Adequate clearance must be provided in aisle and at the side and back. Adequate clearances for air openings into the combustion chamber must be provided, as well as for serviceability for use on noncombustible floors. Minimum clearance from combustible and noncombustible construction, 3 inches on left side, 8 inches on right side and 6 inches from back.
WARNING: These procedures must be followed by qualified personnel or warranty will be voided. An open gap floor drain is required immediately below the appliance drain.
TO INSTALL:
1.Uncrate carefully. Report any hidden freight damage to the freight company immediately.
2.Set the unit in place. Be certain to maintain the minimum clearances from combustibles and
3.Level appliance using spirit level. Should flanged adjustable feet be provided, anchor to floor using proper anchoring devices.
4.Seal bolts and flanged feet with Silastic or other equivalent compound.
5.Be certain to leave adequate clearances for cleaning, maintenance and service.
7