Zephyr AK7548ASX Troubleshooting Procedures for Tempest I and Tempest, Issue Cause What to do

Page 20

www.zephyronline.com

Troubleshooting

TROUBLESHOOTING PROCEDURES FOR TEMPEST I AND TEMPEST II

Issue

Cause

What to do

After installation,

1.

The power source is not turned ON.

1.

Make sure the circuit breaker and the unit’s

the unit doesn’t

 

 

 

power is ON.

work.

 

 

 

 

2.

The power line and the cable locking connector

2.

Check the power connection with the unit is

 

 

 

is not connecting properly.

 

connected properly.

 

 

 

 

 

 

3.

The switch board and control board wirings are

3.

Make sure the wirings between the switch

 

 

disconnected.

 

board and control board are connected

 

 

 

 

properly.

 

4.

The wires on control board are loose.

4.

Make sure the wires on the control board are

 

 

 

 

connected properly.

 

5.

The switch board or control board is defective.

5.

Change the switch board or control board.

Light works,

1.

The motor is defective, possible seized.

1.

Change the motor.

but motor is not

 

 

 

 

2.

The thermally protected system detects if the

2.

The motor will function properly after the

turning.

 

motor is too hot to operate and shuts the motor

 

thermally protected system cool down.

 

 

 

 

 

down.

 

 

 

 

 

 

 

 

3.

Damaged capacitor.

3.

Change the capacitor.

 

4.

The motor wire is not connected.

4.

Make sure the motor wire is plugged into the

 

 

 

 

molex connector.

The unit is

1.

The motor is not secure in place.

1.

Tighten the motor in place.

vibrating.

 

 

 

 

2.

Damaged blower wheel.

2.

Change the blower.

 

 

 

 

 

 

 

3.

The hood is not secured in place.

3.

Check the installation of the hood.

The motor is

1.

Defective halogen bulb.

1.

Change the halogen bulb.

working, but the

 

 

 

 

2.

The light bulb is loose.

2.

Tighten the light bulb.

lights are not.

 

 

 

 

3.

The wires on the control board are loose.

3.

Make sure the wires on control board are

 

 

 

 

 

connected properly.

 

 

 

 

 

The hood is

1.

The hood might be hanging to high from the

1.

Adjust the distance between the cook top and

not venting out

 

cook top.

 

the bottom of the hood within 26” and 36”

properly.

 

 

 

range.

 

2.

The wind from the opened windows or opened

2.

Close all the windows and doors to eliminate

 

 

doors in the surrounding area are affecting the

 

the outside wind fl ow.

 

 

ventilation of the hood.

 

 

 

3.

Blockage in the duct opening or duct work.

3.

Remove all the blocking from the duct work or

 

 

 

 

duct opening.

 

4.

The direction of duct opening is against the wind.

4. Adjust the duct opening direction.

 

 

 

 

 

 

5.

Using the wrong size of ducting.

5.

Change the ducting to correct size.

Heat lamp is not

1.

Toggle switch is not in the on position.

1.

Make sure the heat lamp power is ON.

working.

 

 

 

 

2.

Heat lamp bulb is defective.

2.

Change the heat lamp bulb.

 

 

3.

Heat lamp bulb is loose.

3.

Tighten the heat lamp bulb.

 

 

 

 

 

Metal fi lter is

1.

Metal fi lter is loose.

1.

Change the metal fi lter.

vibrating.

 

 

 

 

2.

Spring clip is broken.

2.

Change the spring clip.

 

 

 

 

 

 

18

Image 20
Contents Use, Care, and Installation Guide Page Table of Contents InstallationImportant Safety Notice To Reduce the Risk of Range TOP Grease FireOperation List of Materials Parts SuppliedInstallation Ducting Calculation Sheet Duct pieces Equivalent number Total Length x usedDucting InstallationMounting Height & Clearance Installation Ducting Options Some Ducting OptionsInstallation Specifications BackCable Lock Installation ElectricalElectrical Mounting the Range Hood This is the top of the board used to hang the hoodInstallation Single and Dual Internal Blowers Installation CBI-600B Horizontal Ducting Conversion Installation CBI-600B Horizontal Ducting Conversion Installation External Blower Preparation CBE-1000 Wiring DiagramFeatures & Controls Touch Controls & Features Blower On/OffMaintenance Cleaning and Filter Removal Surface MaintenanceStainless Steel Baffle Filters Removing Baffle FiltersMaintenance Lights Replacing Light BulbsIssue Cause What to do TroubleshootingTroubleshooting Procedures for Tempest I and Tempest List of Parts and Accessories Replacement PartsOptional Accessories DescriptionLimited Warranty