Troubleshooting
TROUBLESHOOTING PROCEDURES FOR TEMPEST I AND TEMPEST II
Issue | Cause | What to do | |||
After installation, | 1. | The power source is not turned ON. | 1. | Make sure the circuit breaker and the unit’s | |
the unit doesn’t |
|
|
| power is ON. | |
work. |
|
|
|
| |
2. | The power line and the cable locking connector | 2. | Check the power connection with the unit is | ||
| |||||
|
| is not connecting properly. |
| connected properly. | |
|
|
|
|
| |
| 3. | The switch board and control board wirings are | 3. | Make sure the wirings between the switch | |
|
| disconnected. |
| board and control board are connected | |
|
|
|
| properly. | |
| 4. | The wires on control board are loose. | 4. | Make sure the wires on the control board are | |
|
|
|
| connected properly. | |
| 5. | The switch board or control board is defective. | 5. | Change the switch board or control board. | |
Light works, | 1. | The motor is defective, possible seized. | 1. | Change the motor. | |
but motor is not |
|
|
|
| |
2. | The thermally protected system detects if the | 2. | The motor will function properly after the | ||
turning. | |||||
| motor is too hot to operate and shuts the motor |
| thermally protected system cool down. | ||
|
|
| |||
|
| down. |
|
| |
|
|
|
|
| |
| 3. | Damaged capacitor. | 3. | Change the capacitor. | |
| 4. | The motor wire is not connected. | 4. | Make sure the motor wire is plugged into the | |
|
|
|
| molex connector. | |
The unit is | 1. | The motor is not secure in place. | 1. | Tighten the motor in place. | |
vibrating. |
|
|
|
| |
2. | Damaged blower wheel. | 2. | Change the blower. | ||
| |||||
|
|
|
|
| |
| 3. | The hood is not secured in place. | 3. | Check the installation of the hood. | |
The motor is | 1. | Defective halogen bulb. | 1. | Change the halogen bulb. | |
working, but the |
|
|
|
| |
2. | The light bulb is loose. | 2. | Tighten the light bulb. | ||
lights are not. | |||||
|
|
|
| ||
3. | The wires on the control board are loose. | 3. | Make sure the wires on control board are | ||
| |||||
|
|
|
| connected properly. | |
|
|
|
|
| |
The hood is | 1. | The hood might be hanging to high from the | 1. | Adjust the distance between the cook top and | |
not venting out |
| cook top. |
| the bottom of the hood within 26” and 36” | |
properly. |
|
|
| range. | |
| 2. | The wind from the opened windows or opened | 2. | Close all the windows and doors to eliminate | |
|
| doors in the surrounding area are affecting the |
| the outside wind fl ow. | |
|
| ventilation of the hood. |
|
| |
| 3. | Blockage in the duct opening or duct work. | 3. | Remove all the blocking from the duct work or | |
|
|
|
| duct opening. | |
| 4. | The direction of duct opening is against the wind. | 4. Adjust the duct opening direction. | ||
|
|
|
|
| |
| 5. | Using the wrong size of ducting. | 5. | Change the ducting to correct size. | |
Heat lamp is not | 1. | Toggle switch is not in the on position. | 1. | Make sure the heat lamp power is ON. | |
working. |
|
|
|
| |
2. | Heat lamp bulb is defective. | 2. | Change the heat lamp bulb. | ||
| |||||
| 3. | Heat lamp bulb is loose. | 3. | Tighten the heat lamp bulb. | |
|
|
|
|
| |
Metal fi lter is | 1. | Metal fi lter is loose. | 1. | Change the metal fi lter. | |
vibrating. |
|
|
|
| |
2. | Spring clip is broken. | 2. | Change the spring clip. | ||
| |||||
|
|
|
|
|
18