A4) HEBTKP, HESBTKP, HECBTK, HECBTKMB & HEBTA TRIMS

HECBTK

- Cast bay window and grills in classic black trim kit

HECBKMB

-

Cast bay window and grills in midnight black porcelain enamel trim kit

HESBTKP

-

Steel

bay

window

with polished brass and cast grills in classic black trim kit

HEBTKP

-

Steel

bay

window

and bay louvres with polished brass trim kit

Install the bay window after all other installation work has been completed, thoroughly checked, and tested for operation, leaks and proper installation requirements.

DO NOT REMOVE EXISTING GLASS WITH FRAME

HEBTKP

HESBTKP

HECBTK &

 

HECBTKMB

 

 

 

 

 

 

 

 

 

 

 

Fig. 30

Fig. 31

Fig. 32

HECBTKP, HECBTKMB and HESBTKP Trim Assembly

1)Reposition controls.

a)Remove the Fan Speed Control Box (Fig. 33)

b)Attach the Fan Speed Control Box to the Bracket (Fig. 34) and install the Bracket into the Cabinet. Only for RN/RP VALVE units:

c)Install the Control Knobs Extensions onto the appropriate Control Valve Knobs (Fig. 35)

On units fitted with a Honeywell brand control valve the location of the control knobs and the ignitor button may vary slightly from those shown in Fig. 35. The Honeywell extension pieces are visually different in design and are not interchangeable with the RN/RP knobs shown in Fig. 35.

2)Install the hanging brackets, as per Fig. 36.

3)Install the two ceramic pieces inside the bay window, as per Fig.32.

4)Install the bay window by hanging it onto the lower tabs of the hanging brackets, as per Fig. 37.

5)Install the upper grill by engaging the obround holes with the upper tabs of the hanging brackets, as per Fig. 38.

6)Install brass trim to the steel frame as per Fig. 39 (Only for HESBTKP trim)

10003929

22

Image 22
Contents IRHEDV32 Table of Contents Insert Applications Installation InstructionsLocating Your Irving OIL GAS Fireplace Insert MantelsFireplace & Trim Dimensions IRHEDV32Preparation GAS SpecificationsGAS Line Installationgas IRHEDV32 Certified toVenting and Installation Installation of Trim Switch For RP GAS ValvesAdjustment of Levelling BAR If Required TP THVenting Diagram Onto the unit. See and FigFAN KIT FAN Removal InstructionsGeneral Glass Information Glass CleaningInstallation of Logs & Burner Lava Rock Louvre RemovalMaintenance Large Lava Rock PlacementCeramic Refractory Installation Cleaning ProcedureFlame Adjustment Flame CharacteristicsLighting and Operating Instructions Euro SIT SIT Nova HoneywellTrouble Shooting the GAS Control System Honeywell Millivolt Valve CheckReplacement Parts Replacement Parts List DescriptionFrame Assembly Trim AssemblyFrame Mounting General InformationTrim Replacement Parts List KEY DescriptionRhebsl A2 Rhebsl & Rhebxl TrimsRhebxl A3 Rhefa and Rhefp Trims A4 HEBTKP, HESBTKP, HECBTK, Hecbtkmb & Hebta Trims Hebtkp Hesbtkp Hecbtk HecbtkmbHebtkp Trim Assembly Attach magnets and brass trim to the steel frame Hebtkp Hesbtkp Hecbtk & Hecbtkmb A5 Cast Trim Options IMTVenting Components 12 Vent Termination KIT Model Hedvt 8 x