Vermont Casting IRHEDV32 installation instructions Fan Kit, FAN Removal Instructions

Page 8

DAMPER

3" FLEX VENT

TWO PIECES

 

 

CLAMPS & SCREW

 

FASTENER

 

PLATE

 

GASKET

FLUE COLLAR

 

PLATE

 

UNIT

Fig. 8

DAMPER

3" CHIMNEY LINER

 

TWO PIECES

FRONT FRAME

CLAMPS & SCREW

 

 

FLUE COLLAR PLATE

UNIT

Fig. 9

FAN KIT

115 volt, 60 Hz.56W

The fan kit includes the following: fan, temperature sensor, speed control and a 6 ft. cord. The following explains how to start and set the fan for automatic operation.

1.Plug in the electrical cord.

2.Start gas fire - see lighting procedures.

3.Turn on fan speed control.

4.Wait until the unit has warmed up sufficiently to activate the termperature sensor, approximately 5-10 minutes.

5.Once fan starts, adjust speed control to desired fan speed. The fan will now automatically come on every time the fireplace is in operation. Should the fan not be needed simply turn off the speed control.

The appliance, when installed must be elec- trically connected and grounded in accord- ance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian electrical code.

For U.S.A. Installations, follow local codes and the National Electrical code, ANSI/ NFPA No. 70.

Should this fan require servicing, the power supply must be disconnected. For rewiring of any replacement components see Fig. 13.

FAN REMOVAL INSTRUCTIONS

1.Turn off gas and electricity.

2.Remove the front glass.

3.Remove the logs.

CAUTION: LOGS MAY BE HOT

FLUE COLLAR PLATE

FASTENER PLATE

4.Remove burner assembly and rear log support plate.

5.Remove the fan mounting nuts (2 nuts). (Fig. 12)

6.Slip off the electrical connector at the motor.

7.Lift out the fan.

8.To reinstall reverse procedure.

CABINET TOP MOVE

BACK

Thermal sensor is attached

to burner base

Fan is installed at the back of the air intake box

MAKE SURE THE FLUE COLLAR PLATE IS IN CONTACT WITH THE BACK EDGE OF THE CABINET TOP

FASTENER PLATE

PLATE FLUE COLLAR

Fig. 10

Fan speed control/ Junction box

screw studs

Valve

TOP VIEW

Fig. 12

CABINET TOP

MACHINE SCREW AFTER

FASTENED

Fig. 11

A: SPEED CONTROL

 

 

 

 

 

C

B: TEMPERATURE SENSOR

 

 

 

 

 

 

 

 

 

 

 

 

C: FAN

B

 

 

 

 

 

Black

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 13

10003929

8

Image 8
Contents IRHEDV32 Table of Contents Installation Instructions Locating Your Irving OIL GAS Fireplace InsertInsert Applications MantelsFireplace & Trim Dimensions IRHEDV32GAS Specifications GAS Line InstallationgasPreparation IRHEDV32 Certified toInstallation of Trim Switch For RP GAS Valves Adjustment of Levelling BAR If RequiredVenting and Installation TP THVenting Diagram Onto the unit. See and FigFAN KIT FAN Removal InstructionsGlass Cleaning Installation of Logs & Burner Lava RockGeneral Glass Information Louvre RemovalLarge Lava Rock Placement Ceramic Refractory InstallationMaintenance Cleaning ProcedureFlame Adjustment Flame CharacteristicsLighting and Operating Instructions Euro SIT SIT Nova HoneywellTrouble Shooting the GAS Control System Honeywell Millivolt Valve CheckReplacement Parts Replacement Parts List DescriptionFrame Assembly Trim AssemblyFrame Mounting General InformationTrim Replacement Parts List KEY DescriptionRhebxl A2 Rhebsl & Rhebxl TrimsRhebsl A3 Rhefa and Rhefp Trims A4 HEBTKP, HESBTKP, HECBTK, Hecbtkmb & Hebta Trims Hebtkp Hesbtkp Hecbtk HecbtkmbHebtkp Trim Assembly Attach magnets and brass trim to the steel frame Hebtkp Hesbtkp Hecbtk & Hecbtkmb A5 Cast Trim Options IMTVenting Components 12 Vent Termination KIT Model Hedvt 8 x