LINER INSTALLATION - Fig. 6
VENTING DIAGRAM
The collar extending down from the termi- nation base is the air intake connector. Be sure the flex vent, which is connected to this collar, is also connected to the labelled air intake flue collar on the fireplace. Make sure the Flex vent is attached on the correct collar and cap for exhaust as well.
Slide the insulation provided in the termination kit over the two (2) 3" flex liners, (to be attached to the 3" Flue collar and cap of the termination). Feed one 3" flex vent from the bottom of the termination up through the 4" sleeve. Apply
Flue gas exits through the vent termination rain cap
Outside combustion air enters through the lower level of the vent termination
Secure with clamp and three screws
1)Attach flexible pipe to rain cap
2)Secure with clamp
3)Attach raincap to vent termination using three screws
Pull flexible pipe through vent termination
A or B vent with
7" 0 inside minimum
and 14" outside maximum
NOTE:
Minimum Vent Height - 12 feet Maximum Vent Height - 35 feet
In case the fireplace opening is only minimum height 21" (533mm) and access from the front is not possible, then follow the instructions below.
1. | Remove flue collar plate assembly. Unbolt the top |
| fastener plate and move it to the back first before |
| sliding the flue collar plate out from the top of the unit. |
| (See Fig. 7) |
2. | Apply a bead of |
| collar before attaching the liner to the flue collar. |
| Fasten it with two clamps then adjust fastener plate all |
| the way to the back before sliding flue gas plate back |
| onto the unit. (See Fig. 8 and Fig. 9). |
3. | After the flue collar plate is set on the cabinet top, make |
| sure the front edge of the flue collar plate is completely |
| in contact with the back edge of the cabinet top (See |
| Fig. 10). |
EXHAUST
AIR INTAKE
AIR INTAKE COLLAR | EXHAUST COLLAR SECURED | |
WITH LABEL SECURED | ||
WITH CLAMP AND THREE | ||
WITH CLAMP AND | ||
SCREWS | ||
THREE SCREWS | ||
| ||
AIR INTAKE |
|
Fig. 6
4. Put the machine screw back into the fastener plate. |
Bolt the plate until it is locked. (See Fig. 11). |
Under no circumstances should insulation be put between the damper
FLUE COLLAR PLATE
FASTENER PLATE
CABINET TOP MOVE
BACK
and the top of the unit. This may cause condensation and overheating of the unit.
10/24"X 1 1/2" MACHINE SCREW
Fig. 7
10003929 | 7 |