Vermont Casting IRHEDV32 Lighting and Operating Instructions, Euro SIT SIT Nova Honeywell

Page 12

LIGHTING AND OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This fireplace has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly.

B.BEFORE LIGHTING smell all around the fireplace area for gas. Be sure to smell next to the floor be- cause some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace.

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this label.

2.Turn off all electrical power to the fireplace.

3.For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to off position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn clockwise

to "OFF". Do not force.

 

 

 

ILO

OFF

 

 

 

P

T

PILOT

 

 

 

 

 

HI

F

 

 

ON

 

OFF

 

ON

 

F

 

LO

PILOT

O

 

FFO

 

 

 

 

 

 

 

 

 

 

EURO SIT

 

SIT NOVA

HONEYWELL

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step.

7.Remove window frame assembly before lighting pilot. (See Window Frame Assembly Removal in manual).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwise

to "PILOT".

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly de- pressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Re- lease knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

3/8" - 1/2"

•If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

•If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier.

11.Replace window frame assembly.

12.Turn gas control knob to "On" position.

13.For Rn/RP appliances turn the On/Off switch to "On" positin or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

TO TURN OFF GAS TO FIREPLACE

1.

Turn the On/Off switch to Off position or set

4.

Push in gas control knob slightly and

 

the thermostat to lowest setting.

 

turn clockwise

to "OFF". Do

2.

Turn off all electric power to the fireplace if

 

not force.

 

 

service is to be performed.

5.

Close control access panel.

3.Open control access panel.

10003929

12

Image 12
Contents IRHEDV32 Table of Contents Installation Instructions Locating Your Irving OIL GAS Fireplace InsertInsert Applications MantelsFireplace & Trim Dimensions IRHEDV32GAS Specifications GAS Line InstallationgasPreparation IRHEDV32 Certified toInstallation of Trim Switch For RP GAS Valves Adjustment of Levelling BAR If RequiredVenting and Installation TP THVenting Diagram Onto the unit. See and FigFAN KIT FAN Removal InstructionsGlass Cleaning Installation of Logs & Burner Lava RockGeneral Glass Information Louvre RemovalLarge Lava Rock Placement Ceramic Refractory InstallationMaintenance Cleaning ProcedureFlame Adjustment Flame CharacteristicsLighting and Operating Instructions Euro SIT SIT Nova HoneywellTrouble Shooting the GAS Control System Honeywell Millivolt Valve CheckReplacement Parts Replacement Parts List DescriptionFrame Assembly Trim AssemblyFrame Mounting General InformationTrim Replacement Parts List KEY DescriptionA2 Rhebsl & Rhebxl Trims RhebslRhebxl A3 Rhefa and Rhefp Trims A4 HEBTKP, HESBTKP, HECBTK, Hecbtkmb & Hebta Trims Hebtkp Hesbtkp Hecbtk HecbtkmbHebtkp Trim Assembly Attach magnets and brass trim to the steel frame Hebtkp Hesbtkp Hecbtk & Hecbtkmb A5 Cast Trim Options IMTVenting Components 12 Vent Termination KIT Model Hedvt 8 x