Vermont Castings, Majestic Products: DVR33
Installation of Logs
and Lava Rock Material
The logs are fragile and should be handled with care.
Keep the packaging material out of the reach of children, and dispose of the material in a safe manner.
During this procedure, refer to Fig. 40 for log identification.
1.Remove the top louvre assembly.
2.Remove the window frame assembly. See “Window Frame Assembly Removal” on page 23.
3.Fit the rear right log (A34) in place on the rear log support. The hole in the underside of the log fits over the pin on the right end of the support shelf.
4.Fit the front/rear left log (A33) in place on the rear log support. The hole in the underside of the log fits over the pin on the left end of the support shelf.
5.Fit the front right log (A35) in place, the top end of the log with the hole in the underside aligning with the knob on the rear right log (A34), and the other end with the cut slot resting on the right side edge of the front grate.
6.Fit the front center log (A36) on the center slot of the front grate. The flat end of this log sets against the back wall of the front grate plate.
| A33 | A34 |
|
|
A35
A36
Lava Rock: (Part Number 10001454) Remove from packaging and spread over the sides of the burner housing. Do not place this material on the burner tiles.
Fig. 41 DVR33 Log Set Assembly.
NOTE: Glowing lava rock for DVR33 is only allowed to be positioned at the front area (radiant portion) of the burner housing assembly.
Flame and Temperature Adjustment
RN/RP and EN/EP Models
For units equipped with ‘HI/LO’ valves the flame adjustment is accomplished by rotating the ‘HI/LO’ adjustments knob located near the center of the gas control valve (Fig. 41 and Fig. 42).
Turn | Turn clockwise | |
counterclockwise | ||
to increase | ||
to decrease | ||
flame height | ||
flame height | ||
| ||
Honeywell Valve | Honeywell | |
| ||
| ||
Fig. 41 Flame adjustment knob for Honeywell Valve. |
Fig. 40 DVR33 Log Set (top view)
The log set contains two types of lava rocks. Placing these materials is best done after the logs have been installed.
Glowing Lava Rock: (Part Number 57897) Remove from the packaging and spread them over the burner tiles in a random fashion to fill the space highlighted in Fig 41.
Turn | Turn clockwise | |
counterclockwise | ||
to decrease | ||
to increase | ||
flame height | ||
flame height | ||
| ||
SIT Valve | Nova820 | |
| ||
| ||
Fig. 42 Flame adjustment knob for SIT Valve. |
24 | 10004920 |