Vermont Casting DVR33 manual Lighting and Operating Instructions, Lighting Instructions

Page 27
If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury and loss of life.

Vermont Castings, Majestic Products: DVR33

Lighting and Operating Instructions

For Fireplaces equipped with SIT822 Gas Valve (EN or EP) Warning:

For your safety, read the following warnings

before lighting the appliance:

A.This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.

B.BEFORE OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than the air and will settle on the floor.

What to do if you smell gas

Do not try to light any appliance

Do not operate any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppliers instructions.

If you cannot contact your gas supplier call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand do not try to repair it, call a qualified service technician. Force or attempting repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and replace any part of the control system and any gas control that has been under water.

Lighting Instructions

1.STOP! Read the safety information above before continuing.

2.Turn off all electrical power to the appliance.

3.This appliance is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.

4.Access the gas control by lowering the lower access door (louvre assembly).

HI

5.Turn the remote switch, if used, OFF. Turn the wireless remote, if used, OFF.

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP. Follow instructions B in the safety warnings above. If you do not smell gas go onto the next step.

7.Close the access door.

8.Turn ON all electrical power to the appliance.

9.Turn remote switch or wireless remote to ON.

10.If the appliance will not operate, follow the instructions “Turning Off the Gas to the Appliance” (below), and call your service technician or gas supplier.

Turning Off the Gas to the Appliance

1.Turn the remote switch to the “OFF” position.

2.Turn OFF all electrical power to the fireplace if service is required.

3 Open the lower access panel.

4.Turn the shut-off valve on the flexible gas line to the “OFF” position.

1/2" GAS SUPPLY

1/2" NPTx 1/2" FLARE SHUT-OFF VALVE

3/8" FLEX LINE (FROM VALVE)

NOTE: Shut-off valve

is shown in “ON” position

10004920

27

Image 27
Contents Rear Vented Direct Vent Gas Fireplace Model DVR33 Table of Contents Locating Your Fireplace Installation and Operating InstructionsFireplace Dimensions Appliance DimensionsFraming Dimensions Clearance to Combustibles MantelsHearth Gas Inlet and Manifold Pressures Gas SpecificationsFraming and Finishing Final FinishingGas Line Installation Remote ON/OFF Switch InstallationAlternate Switch Location EB-1 Electrical Box Electronic Gas Control Valve General Venting InformationGeneral Venting Information-Termination Location Canadian Installations1 US Installations2Crimped End Pipes General Information for Connecting Vent PipesCanadian Installations USA InstallationsRear Wall Vent Installation Twist Lock PipesRear Wall Vent Application Vent Opening Noncombustible Wall Vent Opening Combustible WallExample B How To Use the Vent GraphVertical Sidewall Application Example aMax 914 mm Vent Opening Noncombustible Wall Vertical Sidewall Installation7DVSKS Below Grade InstallationVertical Through-the-Roof Applications Snorkel installation, recessed foundationMin ’ 610 mm Vertical Through-the-Roof InstallationDVR33 Bracket Restricter Installation Twist Lock Venting Components Crimped End Venting Components Glass Information Window Frame Assembly RemovalGlass Cleaning Operating InstructionsInstallation of Logs Lava Rock Material Flame and Temperature AdjustmentInspecting the Venting System Flame CharacteristicsTo Turn Off Gas To Heater Lighting and Operating InstructionsLighting and Operating Instructions Lighting InstructionsTurning Off the Gas to the Appliance Window Frame Assembly Should be Removed Before Service Work Troubleshooting Honeywell Millivolt ValveTroubleshooting the Gas Control System SIT 822 Valve with a Honeywell Electronic Igniter Fuel Conversion Instructions Burner and Burner Compartment General MaintenanceCleaning Standing Pilot Control System FK24/FK12 Fan AssemblyDVR33 DVR33 Vermont Castings, Majestic Products DVR33 Vermont Castings, Majestic Products DVR33 Fan Kits Hard Wire Direct Hook-UpRemote Controls Ceramic Refractory PanelsDecorative Bay Windows Bay window Decorative Frame TrimsLimited Lifetime Warranty

DVR33 specifications

The Vermont Casting DVR33 is a prominent name in the hearth solutions market, known for blending exceptional design with advanced heating technology. This distinctive gas fireplace is engineered to offer both efficiency and aesthetic appeal, making it a valuable addition to any home.

One of the primary features of the DVR33 is its realistic flame presentation. Utilizing advanced gas burner technology, it creates a mesmerizing fire that mimics the beauty of traditional wood-burning fireplaces. The flames dance and flicker, providing warmth and comfort while generating an inviting ambiance that enhances any living space.

The DVR33 is designed with energy efficiency in mind. With an efficiency rating of up to 80 percent, this model ensures that minimal heat is lost, making it a cost-effective heating solution. It is also equipped with a sealed combustion system that draws air from outside for combustion, ensuring improved indoor air quality and reducing energy costs.

Safety is another critical aspect of the DVR33. It comes with an electronic ignition system that ensures reliable performance without the need for continuous pilot lights, thus conserving energy. The adjustable flame height and heat output provide users with control over their heating needs, allowing for personalized comfort levels depending on the season or occasion.

Aesthetically, the DVR33 offers a customizable design. Homeowners can select from various fronts, finishes, and decorative options, allowing them to seamlessly integrate the fireplace into their existing decor. The unit also includes a realistic ceramic log set that enhances the lifelike appearance of the flames.

In terms of maintenance, the DVR33 is designed for convenience. It requires minimal upkeep, and the accessible controls simplify operation. Additionally, Vermont Castings offers an impressive warranty, underscoring their commitment to quality and customer satisfaction.

Overall, the Vermont Casting DVR33 stands out as a high-quality gas fireplace that combines technology, efficiency, and design. With its beautiful flame presentation, customizable options, and focus on safety, it’s an ideal choice for anyone looking to enhance their home with the warmth and elegance of a gas fireplace.