Vermont Casting DVR33 manual Lighting and Operating Instructions, To Turn Off Gas To Heater

Page 26

Vermont Castings, Majestic Products: DVR33

Lighting and Operating Instructions

FOR YOUR SAFETY, READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

A.This heater has a pilot which must be lit manu- ally. When lighting the pilot follow these instruc- tions exactly.

B.BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace.

Do not touch any electric switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the Fire Department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1.STOP! Read the safety information above.

2.Turn off all electrical power to the fireplace.

3.For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn

clockwise to "OFF".

 

 

 

 

PILOT

OFF

 

 

 

 

PILOT

 

 

1

 

 

t

 

F

 

 

 

 

 

 

o

 

 

ON

ON

P

 

 

F

 

 

F

l

 

 

 

 

 

i

 

2

 

 

 

O

 

 

 

 

F

 

 

O

 

 

5

 

 

FFO

 

4

3

 

 

 

 

 

 

 

 

Euro SIT SIT NOVA

Honeywell

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step.

7.Remove glass door before lighting pilot. (See Glass Frame Removal section).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counter-clockwise

to "PILOT".

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark igniter until a flame appears. Continue to hold the control knob in for about one

(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

• If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

3/8" - 1/2"

If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to “ON” position.

13.For RN/RP appliances turn the On/Off switch to “ON” position or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

To Turn Off Gas To Heater

1.

Turn the On/Off switch to Off position or set the

3.

Open louvre assembly bottom.

 

thermostat to lowest setting.

4.

Push in gas control knob slightly and turn

2.

Turn off all electric power to the fireplace if

 

clockwise

to "OFF". Do not force.

 

service is to be performed.

5.

Close control access panel.

26

10004920

Image 26
Contents Rear Vented Direct Vent Gas Fireplace Model DVR33 Table of Contents Installation and Operating Instructions Locating Your FireplaceFraming Dimensions Fireplace DimensionsAppliance Dimensions Hearth Clearance to CombustiblesMantels Final Finishing Gas SpecificationsFraming and Finishing Gas Inlet and Manifold PressuresAlternate Switch Location Gas Line InstallationRemote ON/OFF Switch Installation EB-1 Electrical Box General Venting Information Electronic Gas Control ValveCanadian Installations1 US Installations2 General Venting Information-Termination LocationUSA Installations General Information for Connecting Vent PipesCanadian Installations Crimped End PipesRear Wall Vent Application Rear Wall Vent InstallationTwist Lock Pipes Vent Opening Combustible Wall Vent Opening Noncombustible WallExample a How To Use the Vent GraphVertical Sidewall Application Example BMax 914 mm Vertical Sidewall Installation Vent Opening Noncombustible WallBelow Grade Installation 7DVSKSSnorkel installation, recessed foundation Vertical Through-the-Roof ApplicationsVertical Through-the-Roof Installation Min ’ 610 mmDVR33 Bracket Restricter Installation Twist Lock Venting Components Crimped End Venting Components Operating Instructions Window Frame Assembly RemovalGlass Cleaning Glass InformationFlame and Temperature Adjustment Installation of Logs Lava Rock MaterialFlame Characteristics Inspecting the Venting SystemLighting and Operating Instructions To Turn Off Gas To HeaterTurning Off the Gas to the Appliance Lighting and Operating InstructionsLighting Instructions Troubleshooting Honeywell Millivolt Valve Window Frame Assembly Should be Removed Before Service WorkTroubleshooting the Gas Control System SIT 822 Valve with a Honeywell Electronic Igniter Fuel Conversion Instructions FK24/FK12 Fan Assembly General MaintenanceCleaning Standing Pilot Control System Burner and Burner CompartmentDVR33 DVR33 Vermont Castings, Majestic Products DVR33 Vermont Castings, Majestic Products DVR33 Hard Wire Direct Hook-Up Fan KitsDecorative Bay Windows Remote ControlsCeramic Refractory Panels Decorative Frame Trims Bay windowLimited Lifetime Warranty

DVR33 specifications

The Vermont Casting DVR33 is a prominent name in the hearth solutions market, known for blending exceptional design with advanced heating technology. This distinctive gas fireplace is engineered to offer both efficiency and aesthetic appeal, making it a valuable addition to any home.

One of the primary features of the DVR33 is its realistic flame presentation. Utilizing advanced gas burner technology, it creates a mesmerizing fire that mimics the beauty of traditional wood-burning fireplaces. The flames dance and flicker, providing warmth and comfort while generating an inviting ambiance that enhances any living space.

The DVR33 is designed with energy efficiency in mind. With an efficiency rating of up to 80 percent, this model ensures that minimal heat is lost, making it a cost-effective heating solution. It is also equipped with a sealed combustion system that draws air from outside for combustion, ensuring improved indoor air quality and reducing energy costs.

Safety is another critical aspect of the DVR33. It comes with an electronic ignition system that ensures reliable performance without the need for continuous pilot lights, thus conserving energy. The adjustable flame height and heat output provide users with control over their heating needs, allowing for personalized comfort levels depending on the season or occasion.

Aesthetically, the DVR33 offers a customizable design. Homeowners can select from various fronts, finishes, and decorative options, allowing them to seamlessly integrate the fireplace into their existing decor. The unit also includes a realistic ceramic log set that enhances the lifelike appearance of the flames.

In terms of maintenance, the DVR33 is designed for convenience. It requires minimal upkeep, and the accessible controls simplify operation. Additionally, Vermont Castings offers an impressive warranty, underscoring their commitment to quality and customer satisfaction.

Overall, the Vermont Casting DVR33 stands out as a high-quality gas fireplace that combines technology, efficiency, and design. With its beautiful flame presentation, customizable options, and focus on safety, it’s an ideal choice for anyone looking to enhance their home with the warmth and elegance of a gas fireplace.