SYSTEM - FRONT PAGE
If GPI Preset mode is selected and no connections are made to the GPI Input
the P2 will always recall preset 1 at power up.
Delay
Frame compensation Delay. Actual Delay time can be tapped using a connected momentary switch.
Calibrate
Use this function to calibrate P2 to a connected GPI controller. E.g. TC Master Fader (not supplied).
To Calibrate:
•Connect GPI Controller to GPI Input and press CALIBRATE.
•Set GPI controller to Minimum position and press “Set Lo Threshold”.
•Set GPI controller to Max position and press “Set Hi Threshold”.
•Press OK and calibration is done.
GPI Current voltage:
Indicates the current voltage on the GPI Input. With no GPI controller connected the voltage is 1000 mV. Therefore it is worth noticing the max indicated value on e.g. Master Fader is a lower value in voltage compared to the min value.
Front Panel Configuration
On this page various preferences for the Front panel controls are set.
Wizard Mode
This parameter sets up the functionality of the front panel WIZARD key. The Wizard function examines part of the program material and automatically finds optimal compression settings based on the evaluation and the selected mode.
Via the TC Icon Editor the Administrator can both enable/disable the WIZARD function and also select between the three modes that determines the intensity of the compression.
Modes
Light
Mild compression is applied for preserved yet controlled dynamics. Only 1 to 2dB.
Normal
Medium compression is applied.
Heavy
A harder compression for maximal control of dynamics. The compression is typically up to 6- 8dB. Consider whether the processing material will suffer from this type of compression.
Lock Mode
This parameter sets up the functionality of the front panel LOCK key. Thereby the editing options for the everyday user can be limited to different degrees.
Press the round LOCK key to activate the Lock function.
21