SYSTEM - NET PAGE & ICON VIEWS
Disable:
No lock function is active.
Lock Wizard:
Wizard function is disabled and cannot be activated via the front panel WIZARD key.
Lock Recall:
No presets can be recalled via the eight front panels preset keys but the Wizard function is enabled.
Lock Panel:
The entire front panel, recall functions, Bypass and Card dump functionality is disabled.
Lock Activation
The two Lock activation modes defines how the Lock function can be activated/deactivated from the front panel.
Hold | : Lock/unlock can be done by holding |
| Lock key for 2 seconds |
Code | : Four digit code entered via the |
| eight front panel controls is needed |
| to unlock front panel controls. |
The unlock code must be entered within |
5 seconds. |
Bypass Mode
Press the round BYPASS key to activate.
Normal | : No Delay in bypass and |
| Dither is active |
Relay | : Bit transparent digital and |
| analog Bypass Relay |
No Codec Delay : No delay in bypass. | |
| Bypass bit transparency. |
Codec Delay | : Delay active in Bypass. |
| Bypass bit transparency. |
Lock Code/Unlock Code
Enter the lock/unlock codes that needs to be entered to lock/unlock front panel controls when in Lock mode (see above).
Yellow LED Threshold
Analog In, Analog Out & Out Threshold Range: 0 to - 20dB
Sets the response Threshold for the two yellow digits in the In/Out meters.
The upper part of this page holds information on the current software versions and the serial number of the accessed unit.
Network identification
A simple naming function that enables you to name each connected unit.
UI - Icon Views
On the Icon Setup page two
Fader appearance
Three options are available. Changes will take place next time you open the TC Icon.
Faders at bottom
22