Zanussi ZGS 682 ICT manual Earth Continuity Check

Page 25

A. EARTH CONTINUITY CHECK

Appliance must be electrically disconnected - meter set on W (Ohms) x 1 scale and adjust zero if necessary.

Test leads from any appliance earth point to earth pin on plug. Resistance should be less than 0.1 W (Ohm), check all earth wires for continuity and all contacts clean and tight.

B.INSULATION CHECK

Appliance electrically disconnected, all switches ON.

a)meter set on W (Ohms) x 1 scale.

Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit.

b)meter set on W (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads less than × (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but no fault is indicated

-a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component.

It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.

25

Image 25
Contents GB IE Thank you for selecting our appliance Contents Installation Important Safety InformationPeople Safety During UseEnvironmental Information ServiceDescription of the Hobs Instructions for the User Lighting OperationBurner Minimum Maximum Diameter Using the hob correctlyPage Hob Top Maintenance and CleaningPan Supports Ignition electrode BurnersSomething Not Working? Symptom SolutionEngineer technical data Instructions for the InstallerBurner Provision for Ventilation Important safety requirementsInstallation Gas Connection Location Fitting the Hob into Worktop Building over a cupboard or drawer BuildingBuilding over a kitchen unit with door Electrical Requirements Electrical ConnectionsPermanent Connection Wiring diagramPreliminary Electrical Systems Check Fault FindingEarth Continuity Check Ignition System / Gas Ignition Procedure Pressure TestingMinimum adjustment CommissioningMethod Conversion from Natural Gas to LPGExclusions Guarantee/Customer Service0870 5 929 Service and Spare PartsEuropean Guarantee Page Page Page Page 35699-4701 01/08 R.0