Do not keep the control knob pressed for more than 15 seconds.

If the burner does not light even after 15 seconds, release the control knob, turn it the "off" position and wait for at least one minute before trying to light the burner again.

When switching on the mains, after installation or a power cut, it is quite normal for the spark generator to be activated automatically.

In the absence of electricity, ignition can occur without the electrical device; in this case, approach the burner with a flame, push the relevant knob down and turn it anti-clockwise until it reaches the maximum position.

If the control knobs become difficult to turn, please contact your local Service Force Centre.

Using the hob correctly

To ensure maximum burner efficiency, it is strongly recommended that you use only pots and pans with a flat bottom fitting the size of the burner used, so that flame will not spread beyond the bottom of the vessel (see the table below).

Burner

minimum

maximum

 

diameter

diameter

Triple crown

180 mm

260 mm

Medium (semi-rapid)

120 mm

220 mm

Medium (front - left)

120 mm

180 mm

Small (auxiliary)

80 mm

160 mm

 

 

 

9

Image 9
Contents GB IE Thank you for selecting our appliance Contents Installation Important Safety InformationPeople Safety During UseEnvironmental Information ServiceDescription of the Hobs Instructions for the User Lighting OperationBurner Minimum Maximum Diameter Using the hob correctlyPage Maintenance and Cleaning Hob TopPan Supports Ignition electrode BurnersSomething Not Working? Symptom SolutionEngineer technical data Instructions for the InstallerBurner Provision for Ventilation Important safety requirementsInstallation Gas Connection Location Fitting the Hob into Worktop Building Building over a cupboard or drawerBuilding over a kitchen unit with door Electrical Requirements Electrical ConnectionsPermanent Connection Wiring diagramPreliminary Electrical Systems Check Fault FindingEarth Continuity Check Ignition System / Gas Ignition Procedure Pressure TestingMinimum adjustment CommissioningMethod Conversion from Natural Gas to LPGExclusions Guarantee/Customer Service0870 5 929 Service and Spare PartsEuropean Guarantee Page Page Page Page 35699-4701 01/08 R.0