Commissioning

When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below.

)1) Turn the gas tap to the MAX position and ignite.

2)Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below.

Procedure:

 

 

 

) 1)

toReMIN.-ignite the burner and set

 

2)

Remove the control knob.

 

3)

To adjust, use a thin bladed

 

 

screwdriver

and turn

the

 

 

adjustment

screw

(see

 

 

diagram) until the flame is

 

 

steady and

does

not

Minimum adjustment

 

extinguish, when the knob is

 

screw

 

turned from MIN to MAX.

Repeat this procedure for all burners.

Pressure Testing

The pressure testing must be carried out on the burners.

)Proceed as follows:

1)Remove the pan supports and the burner caps and crowns.

2)Fit manometer tube over the injector.

3)Turn on the burner gas supply and ignite another burner supply.

The pressure reading should be nominally 20 mbar and must be between 17 mbar and 25 mbar.

4)Turn off the burner supplies.

27

Image 27
Contents GB IE Thank you for selecting our appliance Contents During Use Important Safety InformationInstallation People SafetyEnvironmental Information ServiceDescription of the Hobs Instructions for the User Lighting OperationBurner Minimum Maximum Diameter Using the hob correctlyPage Maintenance and Cleaning Hob TopPan Supports Ignition electrode BurnersSomething Not Working? Symptom SolutionEngineer technical data Instructions for the InstallerBurner Provision for Ventilation Important safety requirementsInstallation Gas Connection Location Fitting the Hob into Worktop Building Building over a cupboard or drawerBuilding over a kitchen unit with door Electrical Requirements Electrical ConnectionsPermanent Connection Wiring diagramPreliminary Electrical Systems Check Fault FindingEarth Continuity Check Ignition System / Gas Ignition Commissioning Pressure TestingProcedure Minimum adjustmentMethod Conversion from Natural Gas to LPGExclusions Guarantee/Customer Service0870 5 929 Service and Spare PartsEuropean Guarantee Page Page Page Page 35699-4701 01/08 R.0