Ignition System / Gas Ignition

Ignitor does not spark

NO

Check plug top fuse and replace if necessary

Check polarity and earth continuity of supply point

Check earth continuity of appliance

YES

Check gas supply at burner

Light burner manually

Check by pass simmer adjusted

Check position of the electrode

Check fitting of burners

Check continuity from 'N' on the mains connector block and "O" on the ignitor unit

Check continuity from 'L' on the mains connector block and the taps ignition switches

Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit

Check for breaks in the insulation of the HT leads

Check continuity from ignition switches connector to ignitor unit

Change the ignitor unit

26

Image 26
Contents GB IE Thank you for selecting our appliance Contents People Safety Important Safety InformationInstallation During UseService Environmental InformationDescription of the Hobs Instructions for the User Operation LightingUsing the hob correctly Burner Minimum Maximum DiameterPage Pan Supports Maintenance and CleaningHob Top Burners Ignition electrodeSymptom Solution Something Not Working?Instructions for the Installer Engineer technical dataBurner Important safety requirements Provision for VentilationInstallation Gas Connection Location Fitting the Hob into Worktop Building over a kitchen unit with door BuildingBuilding over a cupboard or drawer Electrical Connections Electrical RequirementsWiring diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Minimum adjustment Pressure TestingProcedure CommissioningConversion from Natural Gas to LPG MethodGuarantee/Customer Service ExclusionsService and Spare Parts 0870 5 929European Guarantee Page Page Page Page 35699-4701 01/08 R.0