Operation

Hob burners control knobs

The symbols on the knobs mean that :

there is no gas supply

there is maximum gas supply

 

there is minimum gas supply

 

Lighting

the

burners

 

 

For easier

lighting,

proceed before putting

 

)z

a pan on the pan support.

 

To light a burner:

 

 

 

turn the relevant knob anti-clockwise to maximum

 

 

position (

), then push it down to ignite the

 

 

burner.

 

 

 

Triple crown burner

Only for model ZGS 682 ICT

 

z

Upon ignition, keep the knob pushed down

 

 

about

5 seconds.

This will allow the

A

 

"thermocouple" (see diagram - letter D) to be

B

 

heated and the safety device to be switched

 

off, otherwise

the

gas supply would be

 

 

interrupted.

 

 

D

z

Then adjust the flame as required.

C

 

If the burner does not ignite, turn the control knob

 

 

 

to zero, and try again.

 

A - Burner cap

 

If you

cannot

light

the flame even after

B - Burner crown

 

C - Ignition electrode

 

severalattempts, check the "cap" (see diagram

 

D - Thermocouple (only in

 

- letter A) and the"crown" (see diagram - letter

 

model ZGS 682 ICT)

 

B) are in the correct position.

 

 

8

Image 8
Contents GB IE Thank you for selecting our appliance Contents Important Safety Information InstallationPeople Safety During UseService Environmental InformationDescription of the Hobs Instructions for the User Operation LightingUsing the hob correctly Burner Minimum Maximum DiameterPage Pan Supports Maintenance and CleaningHob Top Burners Ignition electrodeSymptom Solution Something Not Working?Instructions for the Installer Engineer technical dataBurner Important safety requirements Provision for VentilationInstallation Gas Connection Location Fitting the Hob into Worktop Building over a kitchen unit with door BuildingBuilding over a cupboard or drawer Electrical Connections Electrical RequirementsWiring diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Pressure Testing ProcedureMinimum adjustment CommissioningConversion from Natural Gas to LPG MethodGuarantee/Customer Service ExclusionsService and Spare Parts 0870 5 929European Guarantee Page Page Page Page 35699-4701 01/08 R.0