8ADJUST THE OVEN BURNER AIR SHUTTER IF NECESSARY (CONT.)
For LP Gas:
The flame should have approximately
If Adjustment is Necessary:
ALoosen the lock screw located at the top of the air shutter, then rotate the air shutter to the correct setting and retighten screw.
| Loosen |
Air | lock |
shutter | screw |
BOven burner flame can be checked as follows (without burner baffle in place):
•To correct a yellow
•To correct a lifting, but distinct, blue
CThe air shutter should be set approximately 2/3 open for natural gas, and approximately full open for LP gas.
DThe oven burner air shutter adjustment is the same on ranges with a gas pilot or electric ignition.
9QUALITY OF FLAMES
The combustion quality of burner flames needs to be determined visually.
(A) Yellow flames: Further adjustment required
(B) Yellow tips on outer cones:
Normal for LP gas
(C) Soft blue flames: Normal for natural gas
If burner flames look like (A), further adjustment is required. Normal burner flames should look like (B) or (C), depending on the type of gas you use.
With LP gas, some yellow tipping on outer cones is normal
10REPLACE OVEN PARTS
After all adjustments are made, replace the oven bottom, shelves and oven door.