GE JGAS02 Quality of Flames, Replace Oven Parts, For LP Gas, If Adjustment is Necessary

Page 31

Installation Instructions

8ADJUST THE OVEN BURNER AIR SHUTTER IF NECESSARY (CONT.)

For LP Gas:

The flame should have approximately

1-inch blue cones. After 30 seconds of burner operation, check for flames lifting off the burner ports. If lifting is observed, gradually reduce the air shutter opening until flames are stabilized. Some yellow tipping may be normal for LP gas.

If Adjustment is Necessary:

ALoosen the lock screw located at the top of the air shutter, then rotate the air shutter to the correct setting and retighten screw.

 

Loosen

Air

lock

shutter

screw

BOven burner flame can be checked as follows (without burner baffle in place):

To correct a yellow flame—Increase size of air shutter opening.

To correct a lifting, but distinct, blue flame—Decrease size of air shutter opening.

CThe air shutter should be set approximately 2/3 open for natural gas, and approximately full open for LP gas.

DThe oven burner air shutter adjustment is the same on ranges with a gas pilot or electric ignition.

9QUALITY OF FLAMES

The combustion quality of burner flames needs to be determined visually.

(A) Yellow flames: Further adjustment required

(B) Yellow tips on outer cones:

Normal for LP gas

(C) Soft blue flames: Normal for natural gas

If burner flames look like (A), further adjustment is required. Normal burner flames should look like (B) or (C), depending on the type of gas you use.

With LP gas, some yellow tipping on outer cones is normal

10REPLACE OVEN PARTS

After all adjustments are made, replace the oven bottom, shelves and oven door.

31

Image 31
Contents 183D9542P005 Pub Number Ran24 Gas gesWhat to do if YOU Smell GAS Ge.com Safety Instructions Operating Instructions CareInstallation of the range section Cook Meat and Poultry THOROUGHLY… Surface Burners Operating Instructions Installation InstructionsSurface Lighting Instructions for Electric Ignition Models Using the gas surface burnersInstallation Instructions Care and Cleaning InstructionsInstructions Operating Top of Range Cookware How to Select Flame SizeUsing the oven Oven Vents Oven Shelf PositionsType of margarine will affect baking performance Using the oven for baking Cakes Cookies SafetyCare and Cleaning Don’t Peek PiesHow to Set the Oven For Roasting Using the oven for roastingAdjust the oven thermostat-Easy to do yourself Safety InstructionsUse of Aluminum Foil Using the oven for broilingSafety Instructions How to Set Your Oven for Broiling Broiler CompartmentComments Broiling GuideTips Consumer Support Care and cleaning of the rangeLift-Up Cooktop Burner GratesOven Shelves and Broiler Rack Cleaning Operating Instructions SafetyBurners Control Panel and KnobsTo remove Cleaning the Oven BottomCleaning Installation Instructions Broiler Compartment Removable Oven BottomInside of door Instructions Safety Broiler Pan and GridLift-Off Oven Door To remove the door800.626.2002 Porcelain Oven Interior SafetyPainted Surfaces Do not use a steel wool pad it will scratch the surfaceBefore YOU Begin Commonwealth of MassachusettsMaterials YOU MAY Need For Your SafetyTools YOU will Need Part IncludedInstallation Safety Instructions Dimensions and Clearances Location ANTI-TIP DeviceProvide Adequate GAS Supply Connect the Range to GASRecommended GAS and Electric Supply Location Flexible ConnectorHookup Example Light the Pilots Seal the OpeningsFor Natural Gas Adjust the Oven Burner AIR Shutter if NecessaryAdjust the Surface Burner Pilots if Necessary If the Range has Electric IgnitionFor LP Gas If Adjustment is NecessaryQuality of Flames Replace Oven PartsLevel the Range Install the ANTI-TIP Device⁄ 8 ″ Mobile Home Installation When ALL Hookups are CompletedModel and Serial Number Location Before you call for service… We Will Replace Gas Range WarrantyWhat is Not Covered Care and CleaningReal Life Design Studio Schedule ServiceParts and Accessories Consumer Support GE Appliances Website

JGAS02 specifications

The GE JGAS02 is an advanced gas turbine designed to meet the growing demand for efficient and reliable energy solutions. With a focus on performance and sustainability, the JGAS02 incorporates a series of cutting-edge technologies that enhance its operational capabilities while reducing its environmental footprint.

One of the standout features of the JGAS02 is its high efficiency rating. The turbine boasts an advanced airfoil design that optimizes airflow and enhances combustion efficiency. This results in reduced fuel consumption and lower emissions, making it an ideal choice for power generation in a world increasingly focused on clean energy solutions.

The JGAS02 utilizes a sophisticated control system that allows for precise monitoring and management of its operation. This system is equipped with predictive analytics, enabling operators to anticipate maintenance needs and minimize downtime. This not only increases the reliability of the turbine but also extends its operational lifespan, providing significant cost savings over time.

Another key characteristic of the JGAS02 is its versatility. It can operate with a variety of fuels, including natural gas, biogas, and even liquid fuels, allowing it to adapt to different market needs and regulatory environments. This flexibility makes it a popular choice for both industrial applications and power plants seeking to diversify their energy sources.

In terms of technology, the JGAS02 features state-of-the-art cooling systems that enhance turbine performance while protecting critical components from high temperatures. Proprietary materials and coatings are employed to ensure durability and longevity in demanding operating conditions.

Moreover, the JGAS02's modular design simplifies maintenance and upgrades, making it easier for operators to implement enhancements as technology evolves. This attention to future-proofing aligns with GE’s commitment to providing long-term value to its customers.

Overall, the GE JGAS02 represents a significant advancement in gas turbine technology. With its blend of high efficiency, operational reliability, and environmental sustainability, it is well-positioned to meet the challenges of modern energy production while supporting a transition to a cleaner energy future.