Disassembly Procedures

!WARNING

To avoid the risk of electrical shock, personal injury or death; disconnect power to oven and shut off gas supply before following any disassembly procedure.

Broil Burner and Ignitor

1.Shut off power and gas supply to unit.

2.Release control panel cover, see "Control Panel" procedure, steps 1 through 5.

3.Remove surface modules located over broiler.

4.Remove screws securing heat reflector.

5.Disconnect gas line from broiler.

6.Remove screws securing broiler ignitor to oven cavity.

7.Remove screws securing broiler to oven cavity.

8.Loosen screws securing rear broiler gaurds to oven cavity.

9.Remove screws securing front of broiler gaurds to oven cavity.

10.Slide front portion of broiler gaurds outward to gain access to broiler.

11. Remove broiler from oven cavity.

12.Replace component and reverse procedure to reassemble.

Bake Gas Valve(s)

NOTE: Located behind kick plate area.

1.Shut off power and gas supply to unit.

2.Remove kick plate from under oven needing servicing.

3.Disconnect and label wire terminals from gas valve.

4.Disconnect fuel lines connected to gas valve.

5.Remove screws securing gas valve bracket to unit chassis.

6.Replace component and reverse procedure to reassemble.

NOTE: Perform gas leak test to ensure unit will not leak and unit operates properly.

Backgaurd

NOTE: This procedure requires removal of unit from installation position.

Remove screws securing panel to backgaurd, located on the back of the unit.

Top Side Panel

1.Remove top portion of module from unit, located next to the side needing replaces.

2.Remove screws securing top side panel to the chassis.

3.Replace component and reverse procedure to reassemble.

Side Panel

NOTE: This procedure requires removal of unit from installation position.

1.Remove top side panel, see "Top Side Panel" procedure.

2.Remove screws securing top, bottom, and rear of side panel to the chassis.

3.Pull outward on the back of the side panel and slide panel to the rear to release side panel from the chassis.

4.Replace component and reverse procedures to reassemble.

Broiler Gas Valve(s)

NOTE: Located in the surface burner box area.

1.Shut off power and gas supply to unit.

2.Release control panel cover, see "Control Panel" procedure, steps 1 through 5.

3.Remove surface module top portion from surface module to gain access to gas valve.

4.Disconnect and label wire terminals from gas valve.

5.Disconnect gas lines connected to gas valve.

6.Remove screws securing gas valve bracket to unit chassis.

7.Replace component and reverse procedure to reassemble.

NOTE: Perform gas leak test to ensure unit will not leak and unit operates properly.

©2004 Maytag Services

16023219

17

Image 17
Contents Service Recognize Safety Symbols, Words, and Labels Customer Service Support CenterImportant Information Web Site Telephone NumberTable of Contents Oven Fires Safety InformationRecognize this symbol as a safety precaution Receiving Oven Safety Practices for ServicerServicing Using the Oven Delayed IgnitionCase of Fire Bake Burner FlameElectrical Requirements Connecting Range to GasExtension Cord GroundingOven Safety Valve Product Safety DevicesPressure Regulator Gas Burner OrificesGeneral Information Ordering Replacement PartsGeneral Information Parts and Accessories ServiceModel Identification Gas ValveTroubleshooting Procedures Problem Possible Cause Correction Component Testing Procedures Component Testing Procedures Removing and Replacing Unit Surface Burner Micro Switches Disassembly ProceduresControl Panel, Rocker Switches, and Indicator Lights Oven and Surface Broiler Infinite SwitchModules Removal Spark ModuleOven Light Socket Convection FanBake Gas Valves Broil Burner and IgnitorBackgaurd Top Side PanelDoor Removal Door DisassemblyGas Regulator Manifold PipeModule Type Front FacadeSurface Burner CharboilThis page is intentionally left Blank