Troubleshooting Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and shut off gas to unit before servicing, unless testing requires power.

Problem

Possible Cause

 

Poor ground at ignitor

Burners will not ignite; no

Weak or failed spark module

spark at top burner.

Low gas pressure

 

 

 

No 120 VAC to range

 

Micro switch contacts not closing

Burner will not ignite. No

Faulty wiring. Bad connection at burner

electrode and electrode socket

spark to burner ignitors

 

when burner knob is rotated

 

to “LITE” position.

 

 

Inoperative spark module

 

Electrode dirty

 

Cracked or broken electrode, electrode

 

wire or electrode socket

 

 

 

Check for cracked ignitor or pinched ignitor

 

wire

 

Poor continuity to ignitor

No spark or only random

Bad ground connection or lack of continuity

to ground or ignitor

spark at one ignitor.

 

 

Cracked or broken ignitor extension lead ...

 

 

 

Shorted valve switch/harness

Unit continues to spark after

 

knob is turned to OFF

Switch has slipped off the valve

position.

 

 

 

Correction

Verify spark.

Replace spark module.

Verify pressure 4” WCP for natural, 10” WCP for LP.

Verify voltage at wall outlet.

Check wiring against appropriate wiring diagram, Verify all terminals and connections are correct and tight. Check micro switch contacts.

Check wiring against appropriate wiring diagram. Verify all terminals and connections are correct and tight.

Check module according to testing procedures information.

Clean electrode.

Replace electrode.

Replace ignitor lead or electrode.

Verify spark.

Tighten ground connection and correct any breaks in ground path from ignitor path to unit ground path.

Replace ignitor lead.

Replace switch/harness. If shorting is caused by excessive spillovers, customer education is advised.

Carefully reposition switch on valve and rotate from OFF to high, several times to verify switch is not broken.

©2004 Maytag Services

16023219

11

Image 11
Contents Service Web Site Telephone Number Customer Service Support CenterRecognize Safety Symbols, Words, and Labels Important InformationTable of Contents Oven Fires Safety InformationRecognize this symbol as a safety precaution Receiving Oven Safety Practices for ServicerServicing Bake Burner Flame Delayed IgnitionUsing the Oven Case of FireGrounding Connecting Range to GasElectrical Requirements Extension CordGas Burner Orifices Product Safety DevicesOven Safety Valve Pressure RegulatorGeneral Information Ordering Replacement PartsGeneral Information Gas Valve ServiceParts and Accessories Model IdentificationTroubleshooting Procedures Problem Possible Cause Correction Component Testing Procedures Component Testing Procedures Oven and Surface Broiler Infinite Switch Disassembly ProceduresRemoving and Replacing Unit Surface Burner Micro Switches Control Panel, Rocker Switches, and Indicator LightsConvection Fan Spark ModuleModules Removal Oven Light SocketTop Side Panel Broil Burner and IgnitorBake Gas Valves BackgaurdManifold Pipe Door DisassemblyDoor Removal Gas RegulatorCharboil Front FacadeModule Type Surface BurnerThis page is intentionally left Blank