Southbend P24-CM Cleaning & Maintenance, Daily Cleaning and Maintenance, STAINLESS-STEEL Surfaces

Page 11

INFRARED CHEESE MELTER

CLEANING & MAINTENANCE

CLEANING & MAINTENANCE

WARNING

Shut off the gas supply to the appliance before cleaning or performing maintenance on any gas appliance.

The appliance may be equipped with a restraint device to limit its movement in order to prevent damage to the gas connection. If disconnection of this restraint is necessary to move the appliance for cleaning or maintenance, reconnect the restraint when the appliance is moved back to its original installed position.

Southbend appliances are sturdily constructed of the best materials and are designed to provide durable service when treated with ordinary care. To expect the best performance, your equipment must be maintained in good condition and cleaned daily. Naturally, the periods for this care and cleaning depend on the amount and degree of usage.

Following daily and periodic maintenance procedures will enhance long life for your equipment. Climatic conditions (such as salt air) may require more thorough and frequent cleaning or the life of the equipment could be adversely affected.

Keep exposed, cleanable areas clean at all times.

DAILY CLEANING AND MAINTENANCE

To prevent excess smoking, the cheese melter grid, bottom drip pan, and the other cheese melter components must be kept clean of food remnants. Use a wire brush or similar scraping utensil. DO NOT use steel wool or a similar scrub pad that will leave small particles, which can get into food. The daily cleaning procedure is as follows:

1.Turn all controls to OFF, shut off the gas supply, and allow time for the cheese melter to cool.

2.Pull out the cheese melter rack and clean it.

3.Remove the bottom drip pan and clean it.

4.Check that nothing has been placed on top of the cheese melter (which will block the escape of combustion exhaust).

5.Check that the air-intake openings on the rear of the cheese melter are not obstructed.

6.Turn on gas supply, check that all controls are turned to OFF, and light the pilots.

MONTHLY CLEANING AND MAINTENANCE

The following tasks should be performed monthly:

1.Check for proper pilot operation. The flame on each pilot should be just large enough to extend along the flame carrier to the burner surface. If adjustment is necessary, call for service.

2.Check for proper burner operation. When the burner control is set to HIGH, the ceramics should glow red and the flame on the surface of the ceramics should be barely visible, with little or no blue haze. When the burner control is set to LOW, the surface of the ceramics should glow very dull red and the flame should have a blue-haze color. The flame should not flutter or “pop.” If adjustment is necessary, call for service.

SEMIANNUAL CLEANING AND MAINTENANCE

At least twice a year the venting system should be examined and cleaned.

STAINLESS-STEEL SURFACES

To remove normal dirt, grease and product residue from stainless steel surfaces that operate at LOW temperature, use ordinary soap and water (with or without detergent) applied with a sponge or cloth. Dry thoroughly with a clean cloth.

To remove BAKED-ON grease and food splatter, or condensed vapors; apply cleanser to a damp cloth or sponge and rub cleanser on the metal in the direction of the polishing lines on the metal. Rubbing cleanser, as gently as possible, in the direction of the polished lines will not mar the finish of the stainless steel. NEVER RUB WITH A CIRCULAR MOTION. Soil and burnt deposits which do not respond to the above procedure can usually be removed by rubbing the surface with SCOTCH-BRITE scouring pads or STAINLESS scouring pads. DO NOT USE ORDINARY STEEL

OWNERS MANUAL 1186531 REV 2 (09/11)

PAGE 11 OF 24

Image 11
Contents Infrared Cheese Melter Safety Precautions Location of Serial Plate IntroductionClearances SpecificationsGAS Requirements VentilationSpecifications Infrared Cheese Melter P72-CM-PT DimensionsLighting After GAS has Been Shut OFF OperationLighting Cheese Melter Pilots Cheese Melter OperationOperation of Infrared Cheese Melter Shutdown of Cheese Melter Semiannual Cleaning and Maintenance Cleaning & MaintenanceDaily Cleaning and Maintenance Monthly Cleaning and MaintenanceCleaning & Maintenance Infrared Cheese Melter Unpacking InstallationMount on Flue Riser of Range Mounting of Infrared Cheese Melter on Flue-RiserMount on Wall Installation of Wall Bracket for Cheese MelterConnect GAS Supply Attaching Legs for Countertop Infrared Cheese MelterAttach Countertop Legs Install Sloped Enclosure Optional Accessory Installation of Sloped Enclosure If OrderedCheck Cheese Melter Operation Check the InstallationSHUT-DOWN and WIPE-CLEAN Cheese Melter Troubleshooting ServiceAdjustment of Cheese Melter Burners Access to Serviceable PartsAccess to Serviceable Parts Adjustment of Cheese Melter PilotsAdjustment of GAS Pressure Regulator Infrared Cheese Melter Infrared Cheese Melter Infrared Cheese Melter

P24-CM specifications

The Southbend P24-CM is a premier commercial gas range designed to meet the demanding needs of professional kitchens. This range is celebrated for its robust construction, thoughtful design features, and efficient cooking capabilities, making it a favorite among chefs and cooks in various culinary settings.

One of the standout features of the P24-CM is its powerful burner system. It comes with four open burners that provide precise temperature control. Each burner is capable of generating up to 30,000 BTUs, allowing chefs to quickly boil, sauté, or simmer food as needed. This versatility is essential in a busy kitchen where time is of the essence.

The P24-CM is constructed from stainless steel, ensuring durability and resistance to the wear and tear of a bustling culinary environment. The stainless steel finish not only enhances the range's aesthetic appeal but also makes it easy to clean and maintain. Its modular design means it can fit seamlessly with other kitchen equipment and promote a more efficient workspace.

Another key feature of the Southbend P24-CM is its 24-inch depth, providing a compact solution for kitchens with limited space. Despite its smaller footprint, this range does not compromise on performance or functionality. The integrated grease tray and removable drip tray streamline the cooking process by simplifying cleanup, ensuring that chefs can focus on their culinary creations rather than maintenance.

The Southbend P24-CM also features a cast iron griddle option, which adds versatility in cooking methods. This heavy-duty griddle allows for evenly distributed heat, making it ideal for cooking a variety of foods, from pancakes to sautéed vegetables. Moreover, the range comes equipped with a heavy-duty oven that operates with an adjustable thermostat, providing consistent baking and roasting results.

The ignition system on the P24-CM is designed for safety and ease of use. It features a pilotless ignition that starts with just the push of a button, minimizing the risk of gas leaks and providing a quick start-up for busy kitchen operations.

In summary, the Southbend P24-CM is an exceptional gas range that combines power, durability, and space efficiency. With its high BTU burners, robust construction, and innovative features, it is tailored to meet the rigorous demands of professional kitchens while offering chefs the tools they need to create culinary masterpieces.