Multiquip QP-40TE manual QP- 40TE General Information, Application

Page 12

QP- 40TE — GENERAL INFORMATION

APPLICATION

The QP-40TE Trash Pump is designed to be used for de- watering applications. Both the suction and discharge ports on the QP-40TE pump use a 4-inch diameter opening, which allows the pump to pump at a rate of approximately 425 gallons/minute (gpm) or 1,600 liters/minute (lpm).

Self priming pumps are designed to purge air from the suction line and create a partial vacuum in the pump body.The reduced atmospheric pressure inside the pump allows water to flow through the suction line and into the pump body.The centrifugal force created by the rotating impeller pressurizes the water and expels it from the pump.

Power Plant

This trash pump is powered by an 11 horsepower air cooled 4- stroke, single cylinder ROBIN EX- 270D gasoline engine that incorporates a low "Oil Alert Feature"

Oil Alert Feature

In the event of low oil or no oil, the ROBIN EX- 270D engine has a built-in oil alarm engine shut-down feature. In the event the oil level is low the engine will automatically shut-down.

Trash Pump

Trash pump derive their name from their ability to handle a greater amount of debris and solids than standard centrifugal pump. These types of pumps generally handle solids up to 1/2 the size of the discharge opening making them less likely to clog. Also trash pumps are capable of handling water with 25% solids by weight.

The advantage of using a trash pump is that it can be quickly and easily disassembled in the field "without tools" and easily cleaned when clogged.

Suction Lift

This pump is intended to be used for dewatering applications and is capable of suction lifts up to 25 feet at sea level. For optimal suction lift performance keep the suction hose or line as short as possible. In general always put the pump as close to the water as possible.

Pump Support

The pump should always be placed on solid stationary ground in a level position.

NEVER place the pump on soft soil. The suction hose or pipe connection should always be checked for tightness and leaks. A small suction leak in the hose or fittings could prevent the pump from priming.

Elevation

Elevations over 3,000 feet will effect the performance of the pump. Due to less atmospheric pressure at higher altitudes, pump DO NOT have the priming ability that they have at sea level.

A general rule of thumb is that for every 1,000 feet of elevation above sea level a pump will lose one foot of priming ability.

For example, in Flagstaff, Arizona where the elevation is approximately 7,000 feet, the pump would have a suction lift of only 18 feet rather than the 25 feet at sea level.

PAGE 12 — QP- 40TE —OPERATION & PARTS MANUAL — REV. #0 (04/13/05)

Image 12
Contents Model QP-40TE Page QP- 40TE Operation & Parts Manual REV. #0 04/13/05 Table of Contents Parts Ordering Procedures Wilmington Ave Carson, CAQP- 40TE Safety Message Alert Symbols Always wear approved respiratory protection when requiredManufacturers Safe operationQP- 40TE Safety Message Alert Symbols QP- 40TE Rules for Safe Operation AlcoholFree flow of cooling air Serious damage toQP- 40TE Rules for Safe Operation QP- 40TE SPECIFICATIONS/DIMENSIONS Pump Suction & Discharge SizeSpecifications Engine QP- 40TE General Information ApplicationAttempting to remove clean-out cover WaterRe-prime later PortQP- 40TE Refueling Plastic TRUCK-BED LinerQP- 40TE Basic Engine QP- 40TE PRE-INSPECTION Engine Engine is hot! or runningQP- 40TE PRE-SETUP Pump Read safety instructions at the beginning of manualPlace the engine ON/OFF switch in the on position QP- 40TE Initial START-UP EnginePlace the engine fuel valve lever to the on position QP- 40TE Initial START-UP Engine Place the fuel shut-off lever in the OFF positionQP- 40TE Maintenance Pump Pump Vacuum TestQP- 40TE Maintenance Pump QP- 40TE Maintenance Engine Engine Maintenance ScheduleQP- 40TE Maintenance Engine QP- 40TE Preparation for Long -TERM Storage Pump StorageQP- 40TE Operation & Parts Manual REV. #0 04/13/05 QP- 40TE Troubleshooting Engine Engine TroubleshootingQP- 40TE Troubleshooting ENGINE/PUMP Sample Parts List Indicated byQP- 40TE Suggested Spare Parts QP- 40TE Pump Assy Pump AssyENGINE, Robin CasingCasing Cover Delivery Cover NPT432 QP- 40TE -OPERATION & Parts Manual REV. #0 04/13/05 NUT DELIVERY/SUCTION Cover M12 Pump M10Spring Washer M12 Spring Washer M10Robin EX270D50021 Engine Crankcase Assy Crankcase AssyValve GUIDE,5.5DX9.5DX27L Stem SEAL, 5DX11.6DX15DX7.8TOIL SEAL, 28.8DX45DX7T Ball BEARING, BB6206, 30DX62DX16BRobin EX270D50021 Engine Crankshaft Assy CRANKSHAFT, Piston AssyCrankshaft CP, 1 Pump Flange NUT, M18X31DX14HWoodruff KEY, 3BX6HX16D Piston PIN, 18DX13DX53LRobin EX270D50021 Engine Intake and Exhaust Assy Intake and Exhaust Group AssyAdjust SCREW, M5X0.5X23L Camshaft CPPIN, CAMSHAFT, 9DX78.5L Spring PIN, 4DX7.5DX11LRobin EX270D50021 Engine AIR Cleaner Assy AIR Cleaner AssyBase CP CoverLabel NUTRobin EX270D50021 Engine Governor Assy Governor Group AssySPRING, Adjust Governor LeverGovernor Shaft Governor ROD CPRobin EX270D50021 Engine COOLING/ Starting Assy Cooling and Starting Group AssyLABEL, Trade Mark 64D Baffle 1, Case CPBaffle 2, Head BoltRobin EX270D50021 Engine Fueltank Assy FUEL, Lubricant AssyLABEL, Warning LABEL, ModelFuel Tank CAP CP UnionRobin EX270D50021 Engine Carburetor Assy Carburetor AssyScrew Adjusting Valve ThrottleValve Choke JET SlowRobin EX270D50021 Engine Flywheel Assy Flywheel AssyWire 1 CP Switch AssyIgnition Coil CP Lamp Coil CP, 15WEX270D50021 Engine Electric Device Assy Electric Device AssyOIL Sensor CP Tapping BoltClamp CP Effective October 1, 2002 Terms and Conditions of Sale Parts QP- 40TE Operation & Parts Manual REV. #0 04/13/05 Heres HOW to GET Help Your Local Dealer is