Multiquip QP-40TE QP- 40TE PRE-SETUP Pump, Read safety instructions at the beginning of manual

Page 17

Before Starting

1.Read safety instructions at the beginning of manual.

2.Place pump as near to water as possible,onafirmflat,levelsurface.

3.Toprimepump,removefillcap(Figure2)andfillpumpcasing with water. If the pump casing is not filled with water before starting, it will not begin pumping.

CAUTION

Pump casing must be filled with water before using pump. Otherwise pump will not be able to begin pumping.

WARNING

DO NOT open fill cap if pump is hot! Water inside may be under pressure.

4.Checkforleaksbetweenpumpandengine.Ifwaterisleaking between the pump and engine housing, the seal inside the pump may be worn or damaged. Continued operation of the pumpisnot recommended.Furtherusageofthe pumpunder this conditions may cause severe water damage to engine.

Hoses and Clamps

1.Check that all hoses are securely attached to the pump. Make certain suction hose (Figure 2) does not have any air leakage.Tighten hose clamps and couplings as required.

2.Itisrecommendedthat 2 clampsbeusedwhensecuringthe suction hose to the inlet side (suction) of the pump.

3.Remember suction hoses must be rigid enough not to collapse when the pump is in operation.

4.Check that the discharge hose (Figure 2) is not restricted. Place hose so that it lays as straight as it is possible on the ground. Remove any twists or sharp bends from hose which may block the flow of water.

QP- 40TE — PRE-SETUP (PUMP)

Suction and discharge hoses are

NOTE available from Multiquip. Contact your nearest dealer for more information.

5.The discharge hose is usually a collapsible (thin-walled) hose, however if a thin-walled discharge hose is not avail- able, a rigid suction hose can be substituted in its place.

6.Make sure the suction strainer (Figure 2) is clean and securely attached to the water end of the suction hose. The strainer is designed to protect the pump by preventing large objects from being pulled into the pump.

CAUTION

The strainer should be positioned so it will remain completely under water. Running the pump with the strainer above water for long periods can damage the pump.

CAUTION

DO NOT pump flammable fluids, corrosive chemicals or fluids containing toxic substances. These fluids can create potentially dangerous health and environmental hazards. Contact local authorities for assistance.

CAUTION

This pump uses a water-cooled mechanical seal to prevent water from seeping into the engine. The passage of water through the pump casing lubricates the seal and prevents it from overheating. NEVER! operate the pump without water in the casing as this will cause damage to the mechanical seal.

QP- 40TE — OPERATION & PARTS MANUAL — REV. #0 (04/13/05) — PAGE 17

Image 17
Contents Model QP-40TE Page QP- 40TE Operation & Parts Manual REV. #0 04/13/05 Table of Contents Wilmington Ave Carson, CA Parts Ordering ProceduresAlways wear approved respiratory protection when required QP- 40TE Safety Message Alert SymbolsManufacturers Safe operationQP- 40TE Safety Message Alert Symbols Alcohol QP- 40TE Rules for Safe OperationFree flow of cooling air Serious damage toQP- 40TE Rules for Safe Operation Suction & Discharge Size QP- 40TE SPECIFICATIONS/DIMENSIONS PumpSpecifications Engine Application QP- 40TE General InformationWater Attempting to remove clean-out coverRe-prime later PortPlastic TRUCK-BED Liner QP- 40TE RefuelingQP- 40TE Basic Engine Engine is hot! or running QP- 40TE PRE-INSPECTION EngineRead safety instructions at the beginning of manual QP- 40TE PRE-SETUP PumpPlace the engine fuel valve lever to the on position Place the engine ON/OFF switch in the on positionQP- 40TE Initial START-UP Engine Place the fuel shut-off lever in the OFF position QP- 40TE Initial START-UP EnginePump Vacuum Test QP- 40TE Maintenance PumpQP- 40TE Maintenance Pump Engine Maintenance Schedule QP- 40TE Maintenance EngineQP- 40TE Maintenance Engine Pump Storage QP- 40TE Preparation for Long -TERM StorageQP- 40TE Operation & Parts Manual REV. #0 04/13/05 Engine Troubleshooting QP- 40TE Troubleshooting EngineQP- 40TE Troubleshooting ENGINE/PUMP Indicated by Sample Parts ListQP- 40TE Suggested Spare Parts Pump Assy QP- 40TE Pump AssyCasing ENGINE, RobinCasing Cover Delivery Cover NPT432 QP- 40TE -OPERATION & Parts Manual REV. #0 04/13/05 Pump M10 NUT DELIVERY/SUCTION Cover M12Spring Washer M12 Spring Washer M10Crankcase Assy Robin EX270D50021 Engine Crankcase AssyStem SEAL, 5DX11.6DX15DX7.8T Valve GUIDE,5.5DX9.5DX27LOIL SEAL, 28.8DX45DX7T Ball BEARING, BB6206, 30DX62DX16BCRANKSHAFT, Piston Assy Robin EX270D50021 Engine Crankshaft AssyFlange NUT, M18X31DX14H Crankshaft CP, 1 PumpWoodruff KEY, 3BX6HX16D Piston PIN, 18DX13DX53LIntake and Exhaust Group Assy Robin EX270D50021 Engine Intake and Exhaust AssyCamshaft CP Adjust SCREW, M5X0.5X23LPIN, CAMSHAFT, 9DX78.5L Spring PIN, 4DX7.5DX11LAIR Cleaner Assy Robin EX270D50021 Engine AIR Cleaner AssyCover Base CPLabel NUTGovernor Group Assy Robin EX270D50021 Engine Governor AssyGovernor Lever SPRING, AdjustGovernor Shaft Governor ROD CPCooling and Starting Group Assy Robin EX270D50021 Engine COOLING/ Starting AssyBaffle 1, Case CP LABEL, Trade Mark 64DBaffle 2, Head BoltFUEL, Lubricant Assy Robin EX270D50021 Engine Fueltank AssyLABEL, Model LABEL, WarningFuel Tank CAP CP UnionCarburetor Assy Robin EX270D50021 Engine Carburetor AssyValve Throttle Screw AdjustingValve Choke JET SlowFlywheel Assy Robin EX270D50021 Engine Flywheel AssySwitch Assy Wire 1 CPIgnition Coil CP Lamp Coil CP, 15WElectric Device Assy EX270D50021 Engine Electric Device AssyClamp CP OIL Sensor CPTapping Bolt Effective October 1, 2002 Terms and Conditions of Sale Parts QP- 40TE Operation & Parts Manual REV. #0 04/13/05 Your Local Dealer is Heres HOW to GET Help