QP- 40TE — PUMP COMPONENTS

Figure 2 shows a typical application using the QP-40TE Trash pump. Please note that this pump is intended for the removal of clean water and water containing some debris and solids. Maximum size of solids should not exceed 2 inches (50 mm) in diameter. DO NOT set strainer on bottom of water bed. Placing the strainer above the water bed will prevent the pump from drawing in excessive amounts of sand and foreign debris.

Figure 2. QP-40TE Pump Application

1.

Pump – The model QP-40TE is 4-inch trash pump used in

 

general de-watering applications. Typical dewatering

 

applications consist of manholes, septic tanks, fast and

 

slow seepage ditch water, silt water, mud water and muck

 

water.

2.

Fill Cap – Prior to operation, the pump casing should be

 

filled with water.Remove this cap to add water to the pump.

 

After the initial prime, a sufficient amount of water will be

 

retained in the casing so that the operator will not need to

 

re-prime later.

 

If the casing is dry or has insufficient water, the pump will

 

have difficulty in priming which could lead to premature

 

mechanical seal wear thus causing damage to the pump.

3.

Discharge Port – Connect a 4-inch discharge hose to this

 

port.

4.

Worm Clamp – Used to secure the hose to the inlet and

 

outlet ports on the pump. Use two clamps to secure the

 

hose on the inlet side of the pump.

5.

Discharge Hose – Connect this flexible rubber hose to

 

the discharge port on the pump. Make sure that the hose

 

lays flat and is not kinked. Use only recommended type

discharge hose. Contact Multiquip parts department for ordering information.

6.

Suction Port – Connect a 4-inch inlet hose to this port.

 

Use two worm clamps to secure the hose.

7.

Suction Hose – Connect this flexible rubber hose to the

 

suction port on the pump. Make sure that the hose lays flat

 

and is not kinked. Use only recommended type suction

 

hose. Contact Multiquip parts department for ordering

 

information

8.

Clean-out Cover Handles – To gain access to the pump's

 

clean-out area, grip both handles, then pull to remove cover.

 

Make sure both locking knobs have been released before

 

attempting to remove clean-out cover.

9.

Drain Plug – Remove this plug to drain water from the

 

pump.

10. Clean-out Cover – Remove cover to gain access to the clean-out area.

11. Locking Knobs– Turn both knobs clockwise to secure clean-out cover, turn counter-clockwise to release cover.

12. Strainer – Always attach a strainer to bottom side of the suction hose to prevent large objects and debris from entering the pump. Strainer should be positioned so that it will remain completely under water.Running the pump with the strainer above water for long periods can damage pump.

QP- 40TE — OPERATION & PARTS MANUAL — REV. #0 (04/13/05) — PAGE 13

Image 13
Contents Model QP-40TE Page QP- 40TE Operation & Parts Manual REV. #0 04/13/05 Table of Contents Wilmington Ave Carson, CA Parts Ordering ProceduresAlways wear approved respiratory protection when required QP- 40TE Safety Message Alert SymbolsManufacturers Safe operationQP- 40TE Safety Message Alert Symbols Alcohol QP- 40TE Rules for Safe OperationFree flow of cooling air Serious damage toQP- 40TE Rules for Safe Operation Suction & Discharge Size QP- 40TE SPECIFICATIONS/DIMENSIONS PumpSpecifications Engine Application QP- 40TE General InformationWater Attempting to remove clean-out coverRe-prime later PortPlastic TRUCK-BED Liner QP- 40TE RefuelingQP- 40TE Basic Engine Engine is hot! or running QP- 40TE PRE-INSPECTION EngineRead safety instructions at the beginning of manual QP- 40TE PRE-SETUP PumpQP- 40TE Initial START-UP Engine Place the engine ON/OFF switch in the on positionPlace the engine fuel valve lever to the on position Place the fuel shut-off lever in the OFF position QP- 40TE Initial START-UP EnginePump Vacuum Test QP- 40TE Maintenance PumpQP- 40TE Maintenance Pump Engine Maintenance Schedule QP- 40TE Maintenance EngineQP- 40TE Maintenance Engine Pump Storage QP- 40TE Preparation for Long -TERM StorageQP- 40TE Operation & Parts Manual REV. #0 04/13/05 Engine Troubleshooting QP- 40TE Troubleshooting EngineQP- 40TE Troubleshooting ENGINE/PUMP Indicated by Sample Parts ListQP- 40TE Suggested Spare Parts Pump Assy QP- 40TE Pump AssyCasing ENGINE, RobinCasing Cover Delivery Cover NPT432 QP- 40TE -OPERATION & Parts Manual REV. #0 04/13/05 Pump M10 NUT DELIVERY/SUCTION Cover M12Spring Washer M12 Spring Washer M10Crankcase Assy Robin EX270D50021 Engine Crankcase AssyStem SEAL, 5DX11.6DX15DX7.8T Valve GUIDE,5.5DX9.5DX27LOIL SEAL, 28.8DX45DX7T Ball BEARING, BB6206, 30DX62DX16BCRANKSHAFT, Piston Assy Robin EX270D50021 Engine Crankshaft AssyFlange NUT, M18X31DX14H Crankshaft CP, 1 PumpWoodruff KEY, 3BX6HX16D Piston PIN, 18DX13DX53LIntake and Exhaust Group Assy Robin EX270D50021 Engine Intake and Exhaust AssyCamshaft CP Adjust SCREW, M5X0.5X23LPIN, CAMSHAFT, 9DX78.5L Spring PIN, 4DX7.5DX11LAIR Cleaner Assy Robin EX270D50021 Engine AIR Cleaner AssyCover Base CPLabel NUTGovernor Group Assy Robin EX270D50021 Engine Governor AssyGovernor Lever SPRING, AdjustGovernor Shaft Governor ROD CPCooling and Starting Group Assy Robin EX270D50021 Engine COOLING/ Starting AssyBaffle 1, Case CP LABEL, Trade Mark 64DBaffle 2, Head BoltFUEL, Lubricant Assy Robin EX270D50021 Engine Fueltank AssyLABEL, Model LABEL, WarningFuel Tank CAP CP UnionCarburetor Assy Robin EX270D50021 Engine Carburetor AssyValve Throttle Screw AdjustingValve Choke JET SlowFlywheel Assy Robin EX270D50021 Engine Flywheel AssySwitch Assy Wire 1 CPIgnition Coil CP Lamp Coil CP, 15WElectric Device Assy EX270D50021 Engine Electric Device AssyTapping Bolt OIL Sensor CPClamp CP Effective October 1, 2002 Terms and Conditions of Sale Parts QP- 40TE Operation & Parts Manual REV. #0 04/13/05 Your Local Dealer is Heres HOW to GET Help