Sharp R-1900M operation manual To Reset the Counter to, To Reset the Air Intake Filter Counter

Page 15

To Reset the Counter to “0”

Each counter can be manually reset to “0” by pressing the START pad after the count is displayed.

*Suppose you want to reset the count for memory number 1 in any Memory Input Method

Procedure

Use Custom Setting Function for Air Intake Filter Counter to change the Air Intake Filter cycle from 001-999. The factory setting is 100 hours. When 100 hours is exceeded, the FILTER indicator in the display will start to flash on and off as a reminder to clean the air filter, even if in the middle of cooking. Furthermore “FILt“ flashes on and off in stead of displaying “ . “ during standby and at the same time FILTER indicator flashes on and off. Clean Air Intake Filter (See page 22 - 23), when the FILTER indicator appears in the display,

x 2 7

1Press the CUSTOM SETTING pad twice within 2 seconds, then enter 7. Total usage will be displayed.

After about 1 sec.

CHECK

and then clear the total usage to reset it to “0” .

*Suppose you want to know the total usage hours which has been 99 hours since the last reset.

ProcedureDisplay

x 2 8 1

0

 

 

 

 

NO.

 

CHECK

 

1

 

 

 

 

 

 

 

 

 

2 Enter memory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO.

 

CHECK

number 1 to check

 

 

After about 1 sec.

the total memory

 

 

 

 

 

 

 

 

usage of memory 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 Press the START pad.

CHECK

 

 

 

 

 

 

 

 

 

 

 

1 Press the CUSTOM SETTING

After about 1 sec.

pad twice within 2 seconds

 

and enter 8, 1.

 

 

CHECK

2Press the STOP/CLEAR pad to exit from the Custom Setting Function.

To Reset the Air Intake Filter Counter

Reset the Air Intake Filter Counter after cleaning the air intake filter.

*Suppose you want to reset the air filter counter which has been 101 hours since the last reset and the Air Intake Filter cycle is preset to 100.

ProcedureDisplay

4Press the STOP/CLEAR pad to exit from the Custom Setting Function.

NOTES:

1.

Only Dual Digit Input method can be used when inputting

 

memory numbers in Counter Check/Clear.

2.

To clear total manual cooking usage, press the MANUAL/

 

REPEAT pad in Step 2 instead of the number pad.

3.

To clear total Express Defrost usage, press the EXPRESS

 

DEFROST pad in Step 2 instead of the number pad.

x 2 8 1

1 Press the CUSTOM SETTING pad twice within 2 seconds and enter 8,1.

After about 1 sec.

CHECK FILTER

4. To clear total usage, skip Step 2.

8. Air Intake Filter Counter

Use Custom Setting Function for Air Intake Filter Counter to check total usage hours since the Air Intake Filter was last reset to “0”.

CU81 : The total used air intake filter time appears.

CU82 : The limit time for using a filter can be changed.

2Press the START pad to reset the counter to “0”.

3Press the STOP/CLEAR pad to exit from the Custom Setting Function.

14

Image 15
Contents Intelligent Thinking Contents Nstallation Mportant Safety InstructionsRadio or TV Interference IMPORTANT! Electrical ConnectionError Mode TroubleshootingCC3 CC1CC2 CC4Oven & Controlpanel Memory Cooking Before OperationOW to Operate the Oven Memory OperationRepeat Digit Input/Auto Start on without the Start pad ProcedureCooking Double/Triple Quantity with Memory Dual Digit Input/Auto Start OFF with the Start padSingle Stage Cooking Manual OperationExpress Defrost with Memory Time CookingRepeat Cooking Express DefrostHelpful TIP for Express Defrost Programme & Customise Custom SettingCooking Completion Signal Setting Operation when Programme Lock on is setAudible Signal Sound Volume Setting To set cooking completion signal volumeProcedureDisplay To check more than one counter Counter Check/ClearCounter Check To Reset the Counter to To Reset the Air Intake Filter CounterAir Intake Filter Counter Selecting Operation in case of Magnetron Failure Air Filter CycleMultiplication Factor for Double/Triple Quantity DisplayExpress Defrost Setting Procedure DisplayPause Timing Saving Memories Repeat Digit Input Programming Multi Stage Cooking Setting Total Cooking Time of Express Defrost Maximum Cooking Time Calculation Other Convenient FeaturesDemonstration Mode MonitorLeaning & Maintenance Antenna Cover CoverDon’t soak the splash cover in detergent or wash it FrameSuitable Cookware Ooking AdviceBrowning dishes Kitchen paperAlways attend the oven closely. Only use to absorb fat May cause a fire in your ovenFood Handling & Preparation Advice for Defrosting Advice for Reheating Efrosting Chart LOWMedium LOW Express Defrost Ooking Chart Medium HighHigh Fresh 20C Tomatoes Min High 100% Eheating ChartSavoury Bread and Pastry Canned Foods Meat Portions Page Alling for Service Replace the Mains PlugCustomer Information Centre Pecifications Other Countries outside the EU European Union