Avery 7112 HF user manual Operation

Page 15

INDEX: Pressing the INDEX key advances the display to the next menu item. May also be used in conjunction with other keys as noted below.

UP ARROW: Increments a value, changes a menu item, or selects the item to ON. The maximum value obtainable is 9999 regardless of decimal point placement.

DOWN ARROW: Decrements a value, changes a menu item, or selects the item to OFF. The minimum value obtainable is –1999 regardless of decimal point placement.

ENTER: Pressing ENTER stores the value or the item changed. If not pressed, the previously stored value or item will be retained. The display will flash once when ENTER is pressed.

UP ARROW & ENTER: Pressing these keys simultaneously brings up the secondary menu starting at the alarm, tune, or cycle item (depending on programming). Pressing these keys for 5 seconds will bring up the secure menu.

INDEX & DOWN ARROW: Pressing these keys simultaneously will allow backing up one menu item, or if at the first menu item they will cause the display to return to the primary menu. If an alarm condition has occurred, these keys may be used to reset the alarm.

INDEX & ENTER: Pressing these keys simultaneously and holding them for 5 seconds allows recovery from the various error messages. The following menu items will be reset:

OPEn InP: Input error message bAd InP: Input error message

CHEC CAL: Check calibration error

Correct the problems associated with the above conditions before using these reset keys. More than one error could be present. Caution is advised since several items are reset at one time.

While in the Primary or Secondary Menu, if no key is pressed for a period of 30 seconds, the display will return to the HOME position displaying the temperature value. While in the Secure Menu, if no key is pressed for a period of 60 seconds, the display will return to the HOME position displaying the temperature value. Outputs are disabled (turned off) when the Secure Menu is active.

NOTE: To move to the Primary Menu quickly from any other menu, press the UP ARROW & ENTER keys followed by pressing the INDEX & DOWN ARROW keys.

Users Manual Electro-Sealer 7112 HF

Operation 11

Image 15
Contents Electro-Sealer 7112 HF This page left blank intentionally Contents Pneumatic Drawings Parts Warranty InformationLimited Warranty ServiceRead ALL Instructions Carefully Safety InstructionsModel 7112 Hopper Feed Heat Sealer Unit Specification To Change Time Settings InstallationLCD General Description Auto SwitchBasic Sealing Leveling the Press Operation Setting the ControlsOperation Security Level Selection Password TableSeries Hopper Feed Regular MaintenanceSymptoms Probable Cause Corrective Action Trouble ShootingSymptoms Probable Cause Corrective Action Symptoms Probable Cause Corrective Action Sealing ProblemsElectrical Drawings TB-3 Electrical Schematic Part7112 HF Hand SW R/H Yellow Brown Black Blue Hand SW L/H TOP Platen Bottom Platen Heater 300 Watt Pneumatic Drawings 70205326 Pneumatic SchematicPage Assembly Drawings Front Panel Assembly Drawing and Cover Front Panel Parts List Frame and Cover Assembly Drawing Frame and Cover Parts List Main Cylinder & Cabinet Assembly Drawing Main Cylinder & Cabinet Parts List Main Cylinder / Platen Assembly Drawing Main Cylinder / Platen Parts List Swing Arm & Base Plate Assembly Drawing Swing Arm & Base Plate Parts List Manifold Assembly Drawing Manifold Parts List Vacuum & Regulator Assembly Drawing Vacuum & Regulator Parts List Hopper Feed Assembly Drawing Hopper Feed Parts List 11 12 8 Bracket, Hopper side rail, RH