Avery 7112 HF user manual Trouble Shooting, Symptoms Probable Cause Corrective Action

Page 18

Trouble Shooting

Symptoms

Probable Cause

Corrective Action

 

 

 

Timer does not move but

Hold Switch turned on.

Hold Switch should be turned off.

press operates

 

 

 

 

 

 

Defective timer.

Replace timer.

 

 

 

No heat / no movements

Bad fuse.

Check and / or replace fuse.

 

 

 

 

No power.

Check power to its source.

Timer moves / heat works

Lack of air pressure

No movement

Binding cylinder

 

Bad 4-way valve

Check main airline.

Disconnect main air line, attempt to move cylinder by hand, loosen air line from 4-way valve to TOP of cylinder; operate machine. If not, replace valve. If air escapes, tighten and check line to the BOTTOM of cylinder.

No heat / no indicator light,

No power

Check wiring

no meter indicator

 

 

 

 

 

No heat / no indicator light.

Bad probe

Replace probe.

Meter reads +50

 

 

 

 

 

Heat out of control

Unit malfunctions.

Replace Unit

 

 

 

 

Probe shorted.

Replace probe.

 

 

 

Heat working, meter not in

Error in manual reset control

Reset according to Athens Booklet.

the green band

 

 

 

 

 

Air leak at 4-way valve

Internal leak in cylinder

Replace or rebuild cylinder

exhaust

 

 

 

 

 

 

Jammed 4-way valve

Replace 4-way valve

 

 

 

Timer will not reset

Reset switch not functioning

Adjust or replace

 

 

 

Vacuum arm stays in the

a) Foot pedal not held down until

1) Hold down until timer hits zero

down position

timer hits zero

 

 

 

 

b) Hold Switch turned on

2) Hold Switch must be off during normal

 

 

operation.

 

c) Timer malfunction

3) Replace timer

 

d) 4-way valve jammed

4) Replace 4-way valve

Vacuum arm stays in up

Reset Switch not functioning

Replace or adjust

position after cycle

 

 

 

 

 

Vacuum arm has no

Broken tension spring

Replace

tension

 

 

 

Broken gear teeth

 

14 Regular Maintenance

Users Manual Electro-Sealer 7112 HF

Image 18
Contents Electro-Sealer 7112 HF This page left blank intentionally Contents Pneumatic Drawings Service Warranty InformationLimited Warranty PartsSafety Instructions Read ALL Instructions CarefullyModel 7112 Hopper Feed Heat Sealer Unit Specification Installation To Change Time SettingsLCD Auto Switch General DescriptionBasic Sealing Leveling the Press Setting the Controls OperationOperation Password Table Security Level SelectionRegular Maintenance Series Hopper FeedTrouble Shooting Symptoms Probable Cause Corrective ActionSymptoms Probable Cause Corrective Action Sealing Problems Symptoms Probable Cause Corrective ActionElectrical Drawings Electrical Schematic Part TB-37112 HF Hand SW R/H Yellow Brown Black Blue Hand SW L/H TOP Platen Bottom Platen Heater 300 Watt Pneumatic Drawings Pneumatic Schematic 70205326Page Assembly Drawings Front Panel Assembly Drawing and Cover Front Panel Parts List Frame and Cover Assembly Drawing Frame and Cover Parts List Main Cylinder & Cabinet Assembly Drawing Main Cylinder & Cabinet Parts List Main Cylinder / Platen Assembly Drawing Main Cylinder / Platen Parts List Swing Arm & Base Plate Assembly Drawing Swing Arm & Base Plate Parts List Manifold Assembly Drawing Manifold Parts List Vacuum & Regulator Assembly Drawing Vacuum & Regulator Parts List Hopper Feed Assembly Drawing Hopper Feed Parts List 11 12 8 Bracket, Hopper side rail, RH