Symptoms | Probable Cause | Corrective Action | |
|
|
| |
Vacuum arm moves too | Flow controls out of adjustment | Adjust for smooth motion, not too fast | |
fast or too slow | |||
|
| ||
|
|
| |
Vacuum arm does not go to | Relay not working | Replace | |
ready position when auto | |||
switch is activated | Switch not working |
|
Will not pull label out of hopper
Vacuum pump off. Poor vacuum. | Check and adjust |
Too much weight in hopper. |
|
Vacuum holes in the arm not |
|
covered by label |
|
Labels feed on bias | Poor vacuum | Increase tension on bleed valve. | |
| |||
| Hopper out of adjustment | Adjust. | |
Feeds two labels at one | Too much vacuum | Decrease tension on bleed valve. | |
time | |||
|
| ||
|
| Thumb stack before loading into hopper. |
Users Manual | Regular Maintenance • 15 |