VXI SM7100, Microwave Matrix ID Register 0x00 Read Only, Logical Address Register 0x00 Write Only

Page 23

www.vxitech.com

DESCRIPTION OF REGISTERS - A16

The following describes the registers shown in the SMIP II Register Map for A16 address space.

 

 

 

ID Register (0x00) — Read Only

 

D11-D0

Manufacturer's ID

 

VXI Technology, Inc., set to F4B16

 

D13-D12

Address Space

 

A16/A24 = 002

 

 

A16/A32 = 012

 

 

 

 

 

D15-D14

Device Class

 

Extended register based device, set to 012

 

 

Logical Address Register (0x00) — Write Only

 

 

 

Sets the new logical address in a dynamically configured module.

 

D7-D0

Logical Address

When set for dynamic configuration (set to FF16) a soft reset will not

 

alter the configured logical address, while a hard reset will set the

 

 

 

 

 

 

register back to FF16.

 

D15-D8

Reserved

Writing to this range has no effect.

Device Type Register (0x02) — Read Only

D11-D0

Model Code

Model 277, set to 11516

D15-D12

Required Memory

2

Mbytes, set to 216, for A24

2

Mbytes, set to A16, for A32

 

 

Status Register (0x04) — Read Only

D15

A24/A32 Active

1

= indicates that A24/A32 memory space access is enabled

0

= indicates that A24/A32 memory space access is locked out

 

 

D14

MODID*

1

= indicates that the module is not selected by the MODID line

0

= indicates that the module is selected by the MODID line.

 

 

D13-D4

Reserved

These bits always read as 11,1111,11112

D3

Ready

This bit always reads as 12

D2

Passed

This bit always reads as 12

D1-D0

Reserved

These bits always read as 112

Control Register (0x04) — Write Only

D15

A24/A32 Enable

1

= write a 1 to this bit to enable A24/A32 memory access

0

= to disable access

 

 

D14-D2

Reserved

Writes to these bits have no effect.

D1

Sysfail Inhibit

Write a 1 to this bit to prevent the module from asserting the

SYSFAIL* line.

 

 

D0

Reset

1

= write a 1 to this bit to force the module into a reset state

0

= write a 0 to release the reset state

 

 

SM7100 Programming

23

Image 23
Contents SM7100 VXI Technology, Inc Table of Contents Restricted Rights Legend WarrantyLimitation of Warranty CertificationEMC C L a R a T I O N O F C O N F O R M I T YTerms and Symbols General Safety InstructionsAvoid Electric Shock Support Resources Programming OverviewSMA SM7100 SpecificationsVswr Introduction Calculating System Power and Cooling RequirementsSetting the Chassis Backplane Jumpers MSB LSB Setting the Logical AddressSelecting the Extended Memory Space VXI Technology, Inc SM7100 Preparation for Use Front Panel Connection SM7000 Switch ConfigurationReturn GND EXTGND SM7100 Module Configuration SM7100 Matrix Schematic Offset Hex VXI Technology, Inc SM7100 Module Configuration Addressing Register AccessOffset Write Function Smip II Register MAP A16Status Register 0x04 Read Only ID Register 0x00 Read OnlyLogical Address Register 0x00 Write Only Device Type Register 0x02 Read OnlyVersion Number Register 0x0E Read Only Offset Register 0x06 Read and WriteReserved Register 0x0A Read Only Reserved Register 0x0C Read OnlySubclass Register 0x1E Read Only NVM Access Resister 0x20 Read OnlyNVM Access Resister 0x20 Write Only Interrupt Control Register 0x1C Read and WriteTrace RAM End Low Register 0x2E Read and Write Trace RAM Start High Register 0x28 Read and WriteTrace RAM Start Low Register 0x2A Read and Write Trace RAM End High Register 0x2C Read and WriteTTL Trigger Polarity Register 0x38 -Write Only Loop EnableTrace Enable Open Trigger Select Register 0x36 -Write OnlyReserved Registers Read and Write Busy Trigger Control Register 0x3C Read and WriteTrigger Advance Register 0x3E Write Only Board Busy Register 0x3E Read OnlyAcfailn AddrBBM/MBB Control Register Read and Write Delay Register Read and Write Writing to the Relays Relay Register OffsetVIA16SPACE Index SM7100