VXI Microwave Matrix, SM7100 user manual General Safety Instructions, Terms and Symbols

Page 6

VXI Technology, Inc.

GENERAL SAFETY INSTRUCTIONS

Review the following safety precautions to avoid bodily injury and/or damage to the product. These precautions must be observed during all phases of operation or service of this product. Failure to comply with these precautions, or with specific warnings elsewhere in this manual, violates safety standards of design, manufacture, and intended use of the product.

Service should only be performed by qualified personnel.

TERMS AND SYMBOLS

These terms may appear in this manual:

WARNING

Indicates that a procedure or condition may cause bodily injury or death.

CAUTION

Indicates that a procedure or condition could possibly cause damage to

 

equipment or loss of data.

These symbols may appear on the product:

ATTENTION - Important safety instructions

Frame or chassis ground

Indicates that the product was manufactured after August 13, 2005. This mark is placed in accordance with EN 50419, Marking of electrical and electronic equipment in accordance with Article 11(2) of Directive 2002/96/EC (WEEE). End-of-life product can be returned to VTI by obtaining an RMA number. Fees for take-back and recycling will apply if not prohibited by national law.

WARNINGS

Follow these precautions to avoid injury or damage to the product:

Use Proper Power Cord

To avoid hazard, only use the power cord specified for this product.

Use Proper Power Source

To avoid electrical overload, electric shock, or fire hazard, do not

 

use a power source that applies other than the specified voltage.

Use Proper Fuse

To avoid fire hazard, only use the type and rating fuse specified for

 

this product.

6

SM7100 Preface

Image 6
Contents SM7100 VXI Technology, Inc Table of Contents Certification WarrantyLimitation of Warranty Restricted Rights LegendC L a R a T I O N O F C O N F O R M I T Y EMCGeneral Safety Instructions Terms and SymbolsAvoid Electric Shock Support Resources Overview ProgrammingSM7100 Specifications VswrSMA Calculating System Power and Cooling Requirements Setting the Chassis Backplane JumpersIntroduction Setting the Logical Address MSB LSBSelecting the Extended Memory Space VXI Technology, Inc SM7100 Preparation for Use Switch Configuration Front Panel Connection SM7000EXT GNDReturn GND SM7100 Module Configuration SM7100 Matrix Schematic Offset Hex VXI Technology, Inc SM7100 Module Configuration Register Access AddressingSmip II Register MAP A16 Offset Write FunctionDevice Type Register 0x02 Read Only ID Register 0x00 Read OnlyLogical Address Register 0x00 Write Only Status Register 0x04 Read OnlyReserved Register 0x0C Read Only Offset Register 0x06 Read and WriteReserved Register 0x0A Read Only Version Number Register 0x0E Read OnlyInterrupt Control Register 0x1C Read and Write NVM Access Resister 0x20 Read OnlyNVM Access Resister 0x20 Write Only Subclass Register 0x1E Read OnlyTrace RAM End High Register 0x2C Read and Write Trace RAM Start High Register 0x28 Read and WriteTrace RAM Start Low Register 0x2A Read and Write Trace RAM End Low Register 0x2E Read and WriteOpen Trigger Select Register 0x36 -Write Only Loop EnableTrace Enable TTL Trigger Polarity Register 0x38 -Write OnlyBoard Busy Register 0x3E Read Only Busy Trigger Control Register 0x3C Read and WriteTrigger Advance Register 0x3E Write Only Reserved Registers Read and WriteAddr AcfailnBBM/MBB Control Register Read and Write Delay Register Read and Write Relay Register Offset Writing to the RelaysVIA16SPACE Index SM7100