9.TROUBLESHOOTING
When engine fails to start or if the engine turns but there is no electricity at the receptacles, perform the following checks.
When engine fails to start :
proper position.
Check fuel level.
Check to make sure that the generator is not connected to an appliance.
~
Check spark plug for loose plug cap.
contamination.
Place engine switch to "CHOKE" position to start engine. ("RUN" position when starting a warm engine.)
If closed,open fuel cock.
If connected, turn off the power switch on the connected appliance or disconnect power cable.
Be sure to press spark plug cap securely.
Remove spark plug and clean electrode.
IILI
When no electricity is generated at receptacle :
Check AC or DC circuit breaker if it is at the normal operating "ON" position.
receptacle for loose connections.
II
Check if engine starting was attempted with the electrical appliance connected.
After making sure that the total wattage of the electrical appliance is within permissible limits
-and there are no defects in the electrical appliance, push AC or DC circuit breaker back into "ON" position.
Secure connection, if necessary.
II
Turn off switch of the electrical appliance or disconnect plug from receptacle and after the generator is in a stable condition, make the connection again.
*If engine still does not start, contact your dealer for further infomation.