Makita G1200R instruction manual Specifications, US Gal

Page 24

11.SPECIFICATIONS

1

DESCRIPTION

 

 

G1200R

1

Engine Model

 

I

EY15D (Wl -145)

 

Displacement

cc l c u i n

 

143 I 8.73

 

Frequency

HZ

 

60

 

Rated Output Watts

 

1000

 

AC Continuous Dutv

 

 

 

 

r OutputMax. Watts AC

I

1200

 

Engine Speed

RPM

 

3600

 

Voltage

V

I

120

 

 

 

 

I

Output DC

 

 

12 Volts

 

I

8.3Amps

 

 

Starting System

 

Recoil

 

Fuel Tank Capacity : Liters

 

3.5

 

 

US Gal.

 

0.9

 

Continuous Operation

 

3.5

 

Hours Per Tank

 

 

 

 

 

 

 

Ignition

 

 

Transistorized

 

Automatic Voltage Regulator

I

Yes

r

A C Circuit Breaker

Yes

1

DCBreaker

 

I

Yes

 

Carburator

 

 

Float

 

AC Receptacle

Unit I Volt

 

2 I 125V (20A)

D

C Receptacle

(Amp)

 

G.F.C.I.

 

 

1

I

Spark Plus

 

I

NGK BR6HS

 

Oil

Liters

 

0.6

 

Capacity

Ounces

 

21.o

 

Low Oil Level

 

 

Yes

 

Shutdown System

 

 

 

 

 

Spark Plug Wrench

 

1

 

with Driver

 

 

 

 

 

 

 

L

 

 

486 (19.1)

 

Dimension W

mm

 

288 (11.3)

 

H

(inches)

 

410 (16.1)

 

Weight

kg

 

27.5 (60.6)

 

 

W s )

 

 

 

 

 

Specifications are subject to change without notice. - 21 -

I

I

I

I

I

I

I

Image 24
Contents Model GI Z O O R Page Table of Contents ForewordSafety Precautions Fire prevention8Prevention of electrical shock Exhaust gas precautions Other safety instructionsNecessary inspections and checks Component Identification Fuel Controls and Indicators Fuel CockVoltmeter DC receptacleFrequency adjusting screw AC circuit breaker DC circuit breakerStarter handle Ground Earth TerminalChecking engine oil level Checking fuel levelChecking the area around the generator Operating Procedures StartingAC application DC application For charging 12V battery only Stopping generator Periodic Maintenance Easy maintenanceDo-it-yourself service Periodic maintenanceEasy Checking and Maintenance Air cleaner servicingCleaning procedure Engine oil changeSpark arrester cleaning Cleaning fuel strainerChecking the spark plug Preparation for Storage Troubleshooting When engine fails to startWhen no electricity is generated at receptacle Heating Resistance Power factor 1.O, No starting current IO.APPLICABLE Wattage of the GeneratorTable below shows the values for a 1OOm wire Specifications US GalWiring Diagram Makita Corporation