Napoleon Fireplaces SRPT03-XXXX owner manual Precautions

Page 3

PRECAUTIONS

NOTE:PLEASE READ THE FOLLOWING SAFETY RULES

WARNING:

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, NFPA58 Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2

The heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

Installation and repair should be done by a qualified service person. The heater should be inspected before use and at least annually by a qualified service person.

More frequent cleaning may be required as necessary. It is imperative that control compartment, burners and circulating air passageways of the heater be kept clean.

Prior to use, check for damaged parts such as tube, regulator, pilot or burner.

All leak tests should be done with a soapy solu- tion. NEVER USE AN OPEN FLAME TO CHECK FOR LEAKAGE.

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.

Keeping the appliance area clear and free from combustible materials, gasoline and other flam- mable vapors and liquids.

Not obstructing the flow of combustion and venti- lation air.

Keeping the ventilation opening(s) of the cylin- der enclosure free and clear from debris.

This appliance shall be used only in a well- ventilated space and shall not be used in a build- ing, garage or any other enclosed area.

Young children should be carefully supervised when they are in the area of the heater.

Clothing or other flammable materials should not be hung from the heater, or placed on or near the heater.

An appliance may be installed with shelter no more inclusive than:

With walls on all sides, but with no overhead cover.

Within a partial enclosure which includes an overhead cover and no more than two side walls. These side walls may be parallel, as in a breezeway, or at right angles to each other.

Any guard or other protective device removed for servicing the heater must be replaced prior to operating the heater.

3

Image 3
Contents Tabletop Patio Heater Precautions SpecificationCarbon Monoxide Hazard Precautions Precautions Tools Needed not Included PreparationParts List Assembly Hardware Used Regulator Safety Check Disconnected cylinder when storage or transportationCheck for leak Operation Before LightingLighting instructions Flame Characteristic Shut down instructions When heater is onOperation pressure checked Re-lightLocating Header for USE Cleaning and Maintenance MAINTENANCE/STORAGEDuring periods of extended inactivity or when transporting StorageBetween uses Problem Probable Cause Solution TroubleshootingONE-YEAR Limited Warranty SRPT03-XXXX