Multiquip J36S60 Inspection/operation, Operation, Lifting the Trowel Onto a Slab, Lifting Bale

Page 21

Centrifugal Safety "STOP" Switch

This trowel has been equipped with a centrifugal safety "STOP" switch (Figure 17). This switch should be tested every time the engine is started.

The switching mechanism of this switch should operate freely and should always be kept in this condition. With the switch in the OFF position, the engine should not start or run. The purpose of this switch is to stop the engine in a runaway situation, (i.e. the operator releasing the handle during operation).

OFF

ON

CENTRIFUGAL

SAFETY “STOP”

SWITCH

Figure 17. Centrifugal Safety "STOP" Switch

Operation

This section is intended to assist the operator with the initial start-up of the walk-behind trowel. It is extremely important that this section be read carefully before attempting to use the trowel in the field. DO NOT use your trowel until this section is thoroughly understood.

Lifting the Trowel Onto a Slab

Extra care should be taken when lifting the trowel off the ground. Serious damage to the machine or personal injury could be caused by dropping a trowel.

WARNING

NEVER attempt to lift this machine alone. NEVER lift the trowel by the guard ring as it may rotate and cause injury.

ALWAYS make certain the handle is secure and use only the manufacturer's approved lifting point. The trowel may be lifted at the center lifting bale by crane or other lifting device of adequate capacity.

inspection/operation

NOTICE

DO NOT attempt to operate the trowel until the Safety, General Information and Inspection sections of this manual have been read and thoroughly understood.

NOTICE

The trowel is heavy and awkward to move around. Use proper heavy lifting procedures and DO NOT lift the trowel by the guard rings.

Lifting Bale

The lift bale provides an optimal lift point for lifting the trowel. When lifting the trowel onto a concrete slab, attach a chain or rope to the lifting bale. Make sure the lifting device has adequate lifting capacity to lift the trowel.

Using a crane or forklift (Figure 18) to lift the trowel is highly recommended, and is perfectly safe for the trowel. ALWAYS use extra care when lifting the trowel off the ground.

LIFT

Figure 18. Lifting the Trowel

j36s60 WALK-BEHIND TROWEL • operatION And parts manual — rev. #1 (01/23/13) — page 21

Image 21
Contents Model j36s60 Fuel and chemical exposure Warnings Silicosis Warning Silicosis/Respiratory WarningsJ36S60 WAKL-BEHIND Trowel Table of ContentsCompletely Training checklistDaily pre-Operation Checklist Daily pre-operation checklistSaFeTy meSSageS Safety InformationGeNeRaL SaFeTy ENgINe SaFeTy TROWeL SaFeTyOrder Form PT-160 Before servicing equipmentTRaNSpORTINg SaFeTy FUeL SaFeTyEmISSIONS INFORmaTION ENvIRONmeNTaL SaFeTy/DeCOmmISSIONINgEmission Control Label Label must remain with the engine for its entire lifeGuaranteed ISO 37442010 Based Trowel SPECIFICATIONS/DIMENSIONSSound Power Level in dBA b M/s 2 ∑A8Engine Specifications General information Engine Subaru 5.7 HP gasoline engine Trowel ComponentsInitial Servicing Engine ComponentsAssembly and Installation Assembly and installationHandle Tube Installation Vibratory T-Handle Bar PlacementPitch Cable Installation Safety Stop Switch ConnectionFlat Handle forward for no pitch blades flatInspection Before StartingEngine Oil Check Belt Check Gearbox OilBelt Guard Check Fuel CheckOperation Inspection/operationLifting the Trowel Onto a Slab Lifting BaleOperation Starting the EnginePlace the engine fuel valve lever in the on position Choke Lever Open Testing the Centrifugal Safety Stop SwitchConcrete Finishing Techniques To Begin TrowelingPitching the Blades Standard Handle Pitching the Blades Quick Pitch HandleManeuvering the Trowel Maneuvering the TrowelStopping The Engine Place the safety stop switch in the OFF positionCombo Blades OptionsClip-On Float Blades Optional Float Discs OptionalQuick Pitch Handle Optional Trowel Arm Adjustment Tool OptionalMaintenance Engine Air Cleaner General CleanlinessEngine check Spark Plug Engine oilBelt Never use a spark plug of incorrect heat rangeBlade Pitch Adjustment Procedure Spark arrester cleaningBushings or bent trowel arms Spider removalChanging blades Trowel arm removalRemove the trowel arm from the spider plate Checking trowel arm straightness Trowel arm Lever adjustmentEnsure the fixture arm is in the up position Shaft and the test surfaceInstalling Pans Onto Finisher Blades ReAssemblyLONG-TERM Storage Troubleshooting engine TroubleshootingAir cleaner dirty? Clean or replace air cleaner Or malfunctioning? Or replace switch if necessary Troubleshooting Walk-Behind Trowel Wiring Diagram Page Explanation of Code in Remarks Column To 3 Units Suggested Spare PartsNameplate and Decals ISO DECAL, LIFTING/CRUSH, 2.4 X ISO DECAL, Read MANUAL, 2.00 DIAISO DECAL, ASK for TRAINING, 2.00 DIA DECAL, Serial PLATE, WBT- ChinaStandard Handle Assy Switch ASSY., Kill Wire ASSY., Kill SwitchSPACER, Slide Block Guide WASHER, FENDER, 1.5OD X 3/8IDQuick-pitch Handle ASSY. option Adjustment PIN NUT , QP Trim Cntl AdjustmentQP Adjustment Block Spring Center BalanceGuard Assy WASHER, Flat SAE 5/16 GRD 9YZ Guard Ring J36 FinisherSCREW, Fast Lead WASHER, Fast Lead StainlessRequires 26 OZ .8 Liters Gearbox Lubricant for Operation Gearbox AssyFLANGE, Input Shaft SEAL, OILBEARING, CUP, Timken #M11910 GEAR, Worm B Input ShaftEngine Assy WIRE, Safety Switch CONNECTOR, Splice TAPLifting Bale Assembly J FIN WEIGHT, Automatic Clutch14 1 Spider AssyLock Washer 3/8 MED Blade AssemblyBUSHING, Trowel ARM Spider PlateBlade Assy Trowel BLADE, 8X14, Finish Trowel BLADE, 8X14, ComboFloat Disc Latch PIN Float PAN, 36-INCHEX17 crankcase assy Stem Seal Valve GuideOIL Seal Ball BearingEX17 crankshaft assy Crankshaft CP Connecting ROD BoltFlange NUT Woodruff KEYEX17 muffler assy PIN CAM Shaft Adjust ScrewRing PIN SpringEX17 air cleaner assy Cover CP PackingLabel Wing NUTEX17 governor assy Governor Lever Spring AdjustGovernor Shaft Governor ROD CPEX17 blower assy Label Trade Mark Blower Housing CPCase CP HeadEX17 Recoil Starter assy Reel Spiral SpringStarter Rope Starter KnobEX17 fuel tank assy Label Warning Fuel Tank CPLabel Model Fuel Tank CAP CPEX17 carburetor assy Choke Valve Throttle ValvePilot JET Choke LeverEX17 ignition coil assy Switch Assy Wire 1 CPFlywheel CP Ignition Coil CPEX17 oil sensor assy OIL Sensor CP 700 2777630121740 20A0130400 780 20A0590100HERE’S HOW to GET Help

J36S60 specifications

The Multiquip J36S60 is a versatile and robust generator designed for various applications, ranging from construction sites to outdoor events. With a focus on reliable power and durability, the J36S60 is engineered to meet the demanding requirements of professionals and contractors alike.

At the heart of the J36S60 is its powerful engine, which provides a maximum output of 36 kVA. This generator is equipped with a 60Hz, 240V output, making it suitable for a wide range of equipment and tools. The J36S60 features a fuel-efficient design, allowing for extended run times that minimize downtime on job sites. It can operate for hours on end, ensuring that you have continuous power for critical tasks.

One of the standout features of the J36S60 is its state-of-the-art control panel. The intuitive control panel provides clear access to various functions, making it easy for users to monitor power output, fuel levels, and maintenance intervals. The panel includes circuit breakers, hour meters, and an easy-to-read digital display, ensuring that operators have all necessary information at their fingertips.

Additionally, the Multiquip J36S60 generator incorporates advanced technologies for noise reduction and fuel efficiency. Its innovative design includes sound-dampening materials and a high-capacity silencer, resulting in quieter operation compared to traditional generators. This feature makes it especially suitable for urban environments where noise regulations are strictly enforced.

The J36S60 is built with durability in mind. The heavy-duty steel frame and powder-coated finish ensure that it can withstand the rigors of demanding job sites and adverse weather conditions. Furthermore, the unit is designed for easy transport, with integrated lifting hooks and a compact design that allows for convenient positioning and relocation.

Safety is a priority with the J36S60, which comes equipped with multiple safety features including low oil shutdown, overload protection, and an emergency stop button. These safety mechanisms ensure that both the operator and the machinery are protected during operation.

Overall, the Multiquip J36S60 is a high-performance generator that excels in providing reliable power in a variety of settings. Its combination of power output, efficient fuel consumption, user-friendly controls, and robust build quality makes it an excellent choice for construction professionals, event coordinators, and anyone in need of dependable portable power.