Multiquip SP706026, SP706020, SP706016, SP706036 Maintenance Schedule, AIR Cleaners Daily

Page 39

MAINTENANCE

MAINTENANCE

WARNING

Certain maintenance operations or machine adjustments require specialized knowledge and skill. Attempting to perform maintenance operations or adjustments without the proper knowledge, skills or training could result in equipment damage or injury to personnel. If in doubt, consult your dealer.

When performing maintenance operations on the saw or engine, follow all safety messages and rules for safe operation stated here and at the beginning of this manual.

Seetheenginemanufacturer’smanualsuppliedwithyourmachine for appropriate maintenance schedule and troubleshooting guide for problems.

WARNING — Accidental Starting Hazards

Accidental starts can cause severe injury or death!

ALWAYS place the ON/OFF switch in the

OFF position.

Engine and muffler surfaces can get HOT!

Allow to cool before servicing.

ALWAYS ensure saw is SECURELY placed on appropriate blocks or jackstands when performing maintenance requiring the

saw to be elevated.

CAUTION — Clean up spills

Avoid slips and falls!

Clean up all engine oil, hydraulic oil, and diesel fuel spills immediately.

Maintenance Schedule

Daily (8-10 Hours)

1.Check fluid levels in engine and reservoir; fill as necessary.

2.Visually inspect for wear and damage.

3.Visually inspect for engine leaks.

4.Check or replace the engine air filters as necessary.

5.Check operation of emergency stop button.

Monthly (125-150 Hours)

1.Change hydraulic oil and filter (first 125 hours, then every 250 hours).

2.Change engine oil and filter.

Yearly (500 Hours)

1.Replace fuel filter cartridge and v-belt.

2.Check fuel lines for leakage.

3.Check battery cables and connectors.

4.Check engine monitoring and warning system.

AIR CLEANERS (DAILY)

The saw utilizes both a primary air filter and a safety air filter (Figure 39). The air filter restriction light (Figure 38, Item A) on the engine status indicator (Figure 38, Item B) will illuminate when the filter is plugged.

A

B

Figure 38. Air Filter Restriction Light

Empty the dust discharge valve daily and clean the discharge slot from time to time (Figure 39).

While the air filters should be checked daily and replaced when necessary, there is no need to “over-service” the air filters. That is, they require no cleaning and do not require the use of oil. If the primary filter becomes clogged, simply replace it.

SP7060 PAVEMENT SAW • OPERATION MANUAL — REV. #0 (02/13/09) — PAGE 39

Image 39
Contents Models Proposition 65 Warning Respiratory Hazards SILICOSIS/RESPIRATORY Warnings Silicosis WarningTable of Contents Page Machine layout, location of components, checking of engine Training ChecklistTraining Checklist Read Operator’s Manual completelyDaily PRE-OPERATION Checklist Daily PRE-OPERATION ChecklistHardware and damage check Always wear approved respiratory protection when required SafetySafety Message Alert Symbols Hazard SymbolsSaw to be elevated Rotating blade can cut and crush. Keep hands and feet clearRules and Regulations General Safety Always keep the work area well-organized  Examine blade flanges for damage and excessive wear Diamond Blade SafetyTransporting VIA TRUCK/TRAILER SAW Lifting and Loading SafetyBattery Maintenance SafetyEmergencies See Figures 1 and 2 and for saw dimensions DimensionsOil bath design, fully enclosed housing SpecificationsLbs Kg Engine SpecificationsBF3L2011 Hydro-gear hydrostatic transmission pumpEngine FeaturesIntended USE / Familiarization Intended USESerial TAG Information Serial TAGSerial TAG is bonded to the inside of the console , Item Controls and Indicators Socket Connector Use to plug in optional lightDepth Stop Allows repeatable cutting depths Components ComponentsOil in crankcase Basic Engine InformationFuel Filter Removes dirt and water from the engine fuel Linked to the accelerator systemRatio Speeds and Blade Guard Size Choosing Proper Blade SizeChoosing Proper Blade Size Engine RPM and Surface Feet per Minute Sfpm SpeedsSurface Feet per Minute Sfpm Data ~ No Load Blade RPM vs. Surface Feet Per Minute SfpmFailure to thoroughly inspect the diamond blade Figure Specific Tools / SAW BladesSpecifictoolsto be Used SAW BladesInstalling the Blade Installing the BladeAlign flange pin through the blade into the inner flange 12 In .48 cm Lbs 56.7-79.4 Kg Stacking Blades for Wide CutsTo accomodate different cutting jobs Blade GuardsBlade Guard Removing a Blade GuardInstalling a Blade Guard Installing the Flange GuardConnect the water delivery hose to the blade guard Figure Water Delivery System Water Delivery SystemsSTAY-LEVEL Handlebars SLH STAY-LEVEL HANDLEBARS/BATTERYBattery Setup To adjust the handlebar heightStorage With Fuel In System Fueling the SAWFueling the SAW Priming the Fuel SystemBlock Heaters Cold Weather OPERATION/POINTER AdjustmentPointer Adjustment Coldweather OperationRaise Lower Controls Setting the Depth IndicatorUntil readjusted RAISE-LOWER ControlsTo Start blade shaft rotation Blade Shaft Engage System / Wheel Drive SystemBlade Shaft Rotation Disengagement System To Stop blade shaft rotationAllow the engine to warm up for several minutes OperationStarting and Stoppingthe Engine Starting the EngineCrank the engine normally until it starts Stopping the EngineRestarting After Running Out of Fuel Operating SynopsisLOADING, Unloading Andtransportingthe SAW Loading and TransportingAIR Cleaners Daily MaintenanceMaintenance Maintenance ScheduleAir Cleaner Components Checking Engine Oil Oil Filter 125 HoursChanging Engine Oil And Filter Lubrication Fuel Filter 500 HoursOil And Fuel Lines Engine Tune-UpDisconnect the air intake hose at the lifting bale , Item a BATTERY/CHARGING SystemCheck and clean battery terminals for corrosion Cooling SystemReplace guards and panels prior to starting the engine Replacing the BatteryRemovable Guards and Access Panels Remove rear access panelBelt Tension Belts and PulleysBlade Shaft Blade Shaft AssemblyAdjust to 3-1/2 notches on the tensioner Rotary BelttensionerDrive System Alignment Removal and ReplacementDrive System Alignment Adjustment Blade AlignmentRemoving the Inner Blade Flange Blade Flange REMOVAL/INSTALLATIONBlade Shaft Tolerance Inner Flange Inside Face Installing the Inner Blade FlangeCircuit Breakers and Starter Relays Maximum CUT Depth AdjustmentRAISE-LOWER System PTO Drive MaintenanceRaise-Lower System Troubleshooting Raise-Lower System TroubleshootingR Control Adjustment Hydraulic System MaintenanceHydraulic Oil System Hydraulic System Drainingthe Hydraulic SystemDecommissioning SAW/COMPONENTS Tips When Draining and Filling the Hydraulic Oil SystemStay-Level Handles SLH Longterm StorageTroubleshooting Engine Necessary Loose, damaged wiring?Battery and starter Intake air restricted?Blade Troubleshooting Troubleshooting BladePage Electrical Diagram UP to S/N AF3700155 Electrical Diagram to SN AF3700155Electrical Diagram S/N AF3700156 and UP Electrical Diagram SN AF3700156 & UPHydraulic Schematic to SN AF3700155 Hydraulic Schematic to SN AF3700155Hydraulic Schematic SN AF3700156 and UP Hydraulic Schematic SN AF3700156 & UPYour Local Dealer is HERE’S HOW to GET Help
Related manuals
Manual 82 pages 45.83 Kb

SP706016, SP706026, SP706030, SP706036, SP706020 specifications

Multiquip is a prominent name in the construction equipment industry, known for its innovative and reliable products. Among its versatile offerings, the Multiquip SP706020, SP706016, SP706036, SP706030, and SP706026 stand out as notable concrete pump models. These pumps provide exceptional performance and efficiency, making them ideal for a wide range of applications.

Each model in this lineup is engineered for maximum durability and reliability. The SP706020, for instance, features a powerful and efficient hydraulic system that allows for smooth operation and consistent performance, even in demanding conditions. It is designed with a robust frame that can withstand rigorous job site environments, ensuring longevity and reduced maintenance.

The SP706016 stands out with its compact design, making it suitable for smaller job sites while still offering high output and efficiency. This model is equipped with advanced safety features, such as emergency stop buttons and pressure relief valves, ensuring safe operation for the user and surrounding personnel.

Notably, the SP706036 is designed for high-capacity pumping. It is ideal for larger projects that require higher output without compromising on efficiency. Its advanced pumping technology reduces the potential for blockages, enhancing overall productivity. The SP706030 presents a balance between power and size, making it an excellent choice for medium-scale projects.

The SP706026 is notable for its energy-efficient design, which minimizes fuel consumption while providing robust performance. This model reflects Multiquip's commitment to sustainability and cost-effectiveness, allowing contractors to save on operational costs over time.

Across the series, user-friendly controls and adjustable settings provide operators with the flexibility needed to handle various types of concrete mixes and job specifications. Additionally, these models are fitted with high-quality components that enhance performance and reduce wear and tear.

In summary, the Multiquip SP706020, SP706016, SP706036, SP706030, and SP706026 are versatile concrete pumps equipped with cutting-edge technology, ensuring high efficiency, reliability, and safety on any job site. Their various features and specifications make them a valuable addition to any construction operation, catering to diverse project needs while ensuring exceptional performance.