Multiquip operation manual DCA-600SSK -TRAILER-SPECIFICATIONS, Specifications

Page 21

DCA-600SSK —TRAILER-SPECIFICATIONS

Table 3. Specifications (Con't)

MODEL

COUPLER

TIRES

WHEELS

AXLE

HUBS

SUSPENSION

ELECTRICAL

 

 

 

 

 

 

 

 

TRLR-10W

2" BALL CLASS

175-13C

13"X4.50"

2200# 2X2

5 LUG

3 LEAF

4 WIRE LOOM W/

 

2 ADJUSTABLE

 

 

 

 

 

4 POLE FLAT

 

 

 

 

 

 

 

 

TRLR-10

2"BALL CLASS

175-13C

13"X4.5"

2200#2X2

5 LUG

3 LEAF

4 POLE FLAT

 

2 ADJUSTABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRLR-10XF

2"BALL CLASS

175-13C

13"X4.5"

2200#2X2

5 LUG

3 LEAF

4 POLE FLAT

 

2 ADJUSTABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRLR-225W

2"BALL CLASS

175-13B

13X4.5"

2200#2X2

5 LUG

Q FLEX

4 POLE FLAT

 

2 ADJUSTABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRLR-BLW 400

2"BALL CLASS

175-13C

13 X 4.5"

2200#2X2

5 LUG

3 LEAF

4 POLE FLAT

 

2 ADJUSTABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRLR-50X

2" BALL CLASS

B78-13LRC

13"X4.50"

3,500 lbs.

5 LUG

4 LEAF

4 POLE RUBBER FLAT

 

 

 

 

2-3/8"

 

 

 

 

 

 

 

 

 

 

 

TRLR-50XF

2" BALL CLASS

B78-13LRC

13"X4.50"

3,500 lbs.

5 LUG

4 LEAF

4 POLE RUBBER FLAT

 

 

 

 

2-3/8"

 

 

 

 

 

 

 

 

 

 

 

TRLR-70W

2" BALL CLASS

205-14C

14"X5"

3,500 lbs.

5 LUG

5 LEAF

4 POLE RUBBER FLAT

 

3" ADJUSTABLE

BIAS (4)

 

3"

 

 

 

 

 

 

 

 

 

 

 

TRLR-70X

2" BALL CLASS

205-14C

14"X5"

3,500 lbs.

5 LUG

5 LEAF

4 POLE RUBBER FLAT

 

3" ADJUSTABLE

BIAS (4)

 

3"

 

 

 

 

 

 

 

 

 

 

 

TRLR-70XF

2" BALL CLASS

205-14C

14"X5"

3,500 lbs.

5 LUG

5 LEAF

4 POLE RUBBER FLAT

 

3" ADJUSTABLE

BIAS (4)

 

3"

 

 

 

 

 

 

 

 

 

 

 

TRLR-100XF

ADJUSTABLE 2-5/6 OPT

205-15C

14"X5.5"

3,500 lbs.

5 LUG

5 LEAF

4 WIRE LOOM

 

3" EYE

BIAS (4)

 

3"

 

 

 

 

 

 

 

 

 

 

 

TRLR-85/125

ADJUSTABLE 2-5/6 OPT

ST225/75R15D

14"x6"

(2)-6,000 lbs.

6 LUG

7 LEAF

4 WIRE LOOM

 

3" EYE

RADIAL (4)

 

 

 

 

 

 

 

 

 

 

 

 

 

TRLR-150XF

3" BALL EYE

750-16 E

16"X7"

(2)-6,000 lbs.

8 LUG

7 LEAF

4 WIRE LOOM

 

 

BIAS (4)

 

 

 

 

 

 

 

 

 

 

 

 

 

TRLR-220XF

3" EYE ADJUSTABLE

ST235/85R16E

16"X7"

(2)-7,000 lbs.

8 LUG

Q FLEX

4 WIRE LOOM

 

 

RADIAL(4)

 

 

 

 

 

 

 

 

 

 

 

 

 

TRLR-300XF

3" EYE ADJUSTABLE

ST235/85R16E

16"X7"

(2)-6,000 lbs.

8 LUG

Q FLEX

4 WIRE LOOM

 

 

RADIAL(6)

 

 

 

 

 

 

 

 

 

 

 

 

 

TRLR-400XF

3" EYE ADJUSTABLE

ST235/85R16E

16"X7"

(3)-7,000 lbs.

8 LUG

Q FLEX

4 WIRE LOOM

 

 

RADIAL(6)

 

 

 

 

 

 

 

 

 

 

 

 

 

TRLR-600XF

5TH WHEEL

ST215/75R17.5H

16"X7"

(3)-10,000 lbs.

8 LUG

7 LEAF

6 WIRE LOOM

 

 

RADIAL (8)

 

 

 

 

 

 

 

 

 

 

 

 

 

TRLR-800AR

5TH WHEEL

ST215/75R17.5H

16"X7"

(3)-10,000 lbs.

8 LUG

AIR-RIDE

6 WIRE LOOM

 

 

RADIAL (8)

 

 

 

 

 

 

 

 

 

 

 

 

 

DCA-600SSK — OPERATION AND PARTS MANUAL (STD)— REV. #7 (04/30/10) — PAGE 21

Image 21
Contents Model DCA-600SSK Diesel engine exhaust and some Proposition 65WARNINGDCA-600SSK Operation and Parts Manual STD- REV. #7 04/30/10 Table of Contents Ordering parts has never been easier Parts Ordering ProceduresDCA-600SSK Specifications DCA-600SSK Operation and Parts Manual STD- REV. #7 04/30/10 Dimensions DCA-600SSK Dimensions TOP and SideDCA-600SSK Dimensions Front , Rear and Doors Hazard Symbols DCA-600SSK Safety Message Alert SymbolsThis generator, other property DCA-600SSK Safety Message Alert SymbolsBurns General SafetyElectrical Safety DCA-600SSK Rules for Safe OperationGenerator Grounding Battery Safety Maintenance SafetyTowing & Transporting Safety DCA-600SSK Rules for Safe OperationEmergencies Typical Generator Grounding Application DCA-600SSK InstallationDCA-600SSK Installation Outdoor InstallationMounting DCA-600SSK -TOWING Rules for Safe Operation Towing Safety PrecautionsDCA-600SSK TRAILER-SAFETY Guidelines Explanation of ChartCoupler Type of hitch used on the trailer for towing DCA-600SSK -TRAILER-SPECIFICATIONS Specifications DCA-600SSK -TRAILER-SPECIFICATIONSMachine Safety Decals DCA-600SSK Operation and Safety DecalsDCA-600SSK Operation and Safety Decals DCA-600SSK Operation and Safety Decals DCA-600SSK Operation and Safety Decals DCA-600SSK General Information Generator Major Components DCA-600SSK Major ComponentsGenerator Control Panel DCA-600SSK Generator Control PanelPilot Lamp Indicates that the generator is working properly DCA-600SSK Generator Control PanelEngine Operating Panels DCA-600SSK Engine Operating PanelFuel Level Gauge Indicates amount of diesel fuel remaining Output Terminal Panel Output Terminal FamiliarizationAccess to Uvwo Terminals DCA-600SSK Output Terminal Panel Overview120VAC Gfci Receptacles Maximum Power Output KW Connecting LoadsDCA-600SSK Output Terminal Panel Overview Over Current RelaySingle Phase Load Three Phase LoadDCA-600SSK- Load Application Voltage Change-Over Board Generator OutputVoltagesGenerator Amperage 240V 480VHow to Read the Output Terminal Gauge DCA-600SSK Generator OUTPUTS/GAUGE ReadingMaximum Amps Uvwo Terminal Output Voltages DCA-600SSK Output Terminal Panel Connections3Ø-240V Uvwo Terminal Output Voltages 1Ø-240V Uvwo Terminal Output Voltages3Ø-480V Uvwo Terminal Output Voltages DCA-600SSK Output Terminal Panel Connections1Ø-480V Uvwo Terminal Output Voltages 1Ø-277V Uvwo Terminal Output VoltagesDCA-600SSK PRE-SETUP Circuit BreakersLubrication Oil Refueling Procedure RefuelingFuel from the secondary inner Full Trailer Tank Cleaning the Radiator DCA-600SSK- PRE-SETUPAir Cleaner Fan Belt Tension Operation Freezing WeatherBattery Cable Installation BatteryWiring AlternatorEngines exhaust contains harmful emissions DCA-600SSK GEN. START-UP Procedure ManualIf applicable perform the following Generator and Control PanelSet the battery ON/OFF switch to the on position DCA-600SSK- Generator START-UP Procedure ManualOil Pressure Gauge DCA-600SSK- Generator START-UP Procedure ManualPre-Heat Button Lamp DCA-600SSK Generator START-UP Procedure ManualSet the engine speed switch to the High position DCA-600SSK Generator START-UP Procedure Auto ModeDCA-600SSK Generator SHUT-DOWN Procedure Emergency Shutdown ProcedureEngine Shutdown Controller S/N 3698617~ Inspection / Maintenance DCA-600SSK MaintenanceService Daily Air CleanerCleaning the Fuel Strainer General InspectionFlushing Out Radiator and Changing Coolant Changing OilReplacing Fuel Filter Greasing Cleaning Breather ElementGenerator Storage Removal From Long Term StorageBattery Charger/Jacket Water Heater Power Connections DCA-600SSK -TRAILER Brakes Maintenance Tires/Wheels/Lug Nuts DCA-600SSK -TRAILER MaintenanceTire Wear/Inflation SuspensionLug Nut Torque Requirements DCA-600SSK -TRAILER MaintenanceStart all wheel lug nuts by hand Lug nutsTrailer Wiring Diagram 5-Pin DCA-600SSK -TRAILER-WIRING DiagramDCA-600SSK -TRAILER-WIRING Diagram Generator Wiring Diagram DCA-600SSK -GENERATORWIRING DiagramMain Circuit Breaker Wiring Diagram DCA-600SSK Generator Wiring Diagram Main BreakerEngine Wiring Diagram DCA-600SSK Engine Wiring DiagramDCA-600SSK Engine Wiring Diagram Electronic Governor Controller DCA-600SSK Electronic GOV. Controller Wiring DiagramStarter does not run Engine does not startEngine revolution is not DCA-600SSK -TROUBLESHOOTING EngineSmooth Deficient outputGenerator Troubleshooting DCA-600SSK -TROUBLESHOOTING GENERATOR/ENGINEEngine Controller Troubleshooting Mpec DCA-600SSK -TROUBLESHOOTING MpecXxxxx only Not Used on Explanation of Code in Remarks ColumnDCA-600SSK Suggested Spare Parts DCA-600SSK w/SA6D170AE-1 Komatsu EngineQty Description Generator Assy DCA-600SSK Generator AssyField Assy Balancing Weight KITInsulator Washer FANDCA-600SSK Generator Assy Plain Washer GrommetCOVER, Bearing GASKET, BearingControl BOX Assy DCA-600SSK Control BOX AssyBracket Over Current RelayFuse Left Side 5A Fuse 30ADCA-600SSK Control BOX Assy Terminal Plate Change TerminalChange Plate WASHER, LockDCA-600SSK Control BOX Assy DCA-600SSK Control BOX ASSY. S/N 3692433 and below DCA-600SSK Control BOX Assy Speed Sensor Engine & Radiator Assy DCA-600SSK Engine & Radiator AssyInclude Item W BRACKET, RadiatorEngine Foot DCA-600SSK Engine & Radiator Assy AIR Cleaner Connector AIR Cleaner AssyGASKET, AC Connector BushingEngine Operating Panel Assy DCA-600SSK Engine Operating Panel AssySTAY, Battery Switch SET PLATE, Battery SwitchSupport LEG Rubber CoverOutput Terminal Assy DCA-600SSK Outputterminal AssyBRACKET, Output Terminal Output TerminalTerminal COVER, Output TerminalDCA-600SSK Outputterminal Assy Cover StopperBattery Assy DCA-600SSK Battery AssyBattery Sheet BatteryBattery Band Battery BoltMuffler Assy DCA-600SSK Muffler AssyExhaust Pipe MufflerOutlet Pipe GasketFuel Tank Assy DCA-600SSK Fueltank AssyTank Band HOSE, Fuel GaugePAD, Tank Band Tank SheetEnclosure #1 Assy DCA-600SSK Enclosure #1 AssyPart Name QTY Remarks Enclosure #2 Assy DCA-600SSK Enclosure #2 AssyLouver Panel Rear FrameCOVER, Rear Frame LiningDCA-600SSK Enclosure #2 Assy Emblem CAPRoof Panel GuideEnclosure #3 Assy DCA-600SSK Enclosure #3 AssySide Door Side PanelDuct HingeRubber Seal Assy DCA-600SSK Rubber Seal Assy0228900970 02289016400228901100 0228900990Name Plate and Decals DCA-600SSK Nameplate and DecalsZ011000130 Decal DROOP, Z011000120Z011000150 0800520100DCA-600SSK Nameplate and Decals Decal Handling Procedures Procedure GroupDecal 3-PHASE Output Terminal Decal Water Drain CockFreightpolicy Terms and Conditions of Sale PartsDCA-600SSK Operation and Parts Manual STD- REV. #7 04/30/10 HERE’S HOW to GET Help

DCA-600SSK specifications

The Multiquip DCA-600SSK is a rugged, reliable, and high-performance mobile generator that caters to a wide range of applications, from construction sites to outdoor events. Designed for durability and efficiency, the DCA-600SSK is notable for its robust construction and advanced technologies that ensure reliable power delivery.

At its core, the DCA-600SSK is powered by a reliable, fuel-efficient diesel engine. This engine not only provides consistent power output but also offers extended run times, making it ideal for long-duration use in remote locations. The generator delivers a remarkable 600 kVA of power, allowing it to support heavy machinery or multiple smaller loads simultaneously.

One of the standout features of the DCA-600SSK is its impressive sound attenuation design. The generator is enclosed in a weather-resistant, sound-attenuated housing that significantly reduces noise levels, making it suitable for use in noise-sensitive environments, such as residential areas or events.

Additionally, the DCA-600SSK is equipped with a user-friendly digital control panel that provides comprehensive monitoring capabilities. This panel includes features such as voltage and frequency regulation, along with automatic start/stop functionality, which enhances both ease of use and operational efficiency. The digital display allows operators to monitor critical parameters at a glance, ensuring optimal performance and safety.

The generator is also designed with mobility in mind. It comes with forklift pockets and lifting hooks, making it easy to transport and relocate. This portability ensures quick setup and deployment, which is especially advantageous in dynamic job sites or temporary power needs.

Another important characteristic of the DCA-600SSK is its dual-frequency capability. It can operate at either 50 Hz or 60 Hz, making it versatile for international applications. This adaptability enables users to utilize the generator in various regions without modifying equipment or loads significantly.

Finally, safety features are paramount in the design of the DCA-600SSK. It includes fully automatic safety shutdowns for low oil pressure, high coolant temperature, and overload protection, safeguarding the generator from potential damage and ensuring dependable performance in demanding conditions.

In summary, the Multiquip DCA-600SSK is a powerhouse generator combining high performance, advanced technology, and user-centric design. Its efficiency, portability, and durability make it an excellent choice for professionals seeking reliable power solutions in various settings.