Multiquip DCA-800SSK Rules for Safe Operation, Generator Grounding, Electrical Safety

Page 13
WET
HANDS

DCA-800SSK — RULES FOR SAFE OPERATION

Generator Grounding

To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground.

Article 250 (Grounding) of the National Electrical Code (NEC) provides guide lines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical.

The following safety recommendations should also be followed:

ALWAYS make sure generator is properly grounded.

NEVER use gas piping as an electrical ground.

DANGER - ELECTROCUTION HAZARDS

During operation of this generator, there exists the possibility of electrocution, electrical shock or burn, which can cause severe bodily harm or even DEATH!

To avoid these hazards:

NEVER use damaged or worn cables when connecting equipment to the generator. Make sure power connecting cables are securely connected to the generator’s output terminals, insufficient tightening of the terminal connections may cause damage to the generator

and electrical shock.

ALWAYS make sure that electrical circuits are properly

grounded per the National Electrical Code (NEC) and

local codes before operating generator. Severe injury or

DEATH! by electrocution can result from operating an

ungrounded generator.

ALWAYS be sure to use the ground terminal (green wire)

when connecting a load to the U,V, and W output

terminal lugs.

Electrical Safety

ALWAYS have a qualified electrician perform the generator wiring installation.

ALWAYS make sure generator installation is accordance with the National Electrical Code (NEC) and local codes before operating generator.

NEVER use a defective or frayed power cable. Check the cable for cuts in the insulation.

NEVER use a extension cord that is frayed or damaged where the insulation has been cut.

ALWAYS make certain that proper extension cord has been selected for the job. See Table 6.

NEVER power cables or cords lay in water.

NEVER stand in water while AC power from the generator is being transfer to a load.

NEVER grab or touch a live power cord with wet hands.

NEVER touch output terminals during operation. This is extremely dangerous. ALWAYS stop the machine and place the circuit breaker in the OFF position when contact with the output terminals is required.

Backfeed to a utility system can cause electrocution and or property damage. DO NOT connect to any building's electrical system except through an approved device or after building main switch is opened. ALWAYS have a licensed electrician perform the installation

POWER

CORD

(POWER ON)

DCA-800SSK (STD) — OPERATION AND PARTS MANUAL — REV. #4 (06/03/10) — PAGE 13

Image 13
Contents Model DCA-800SSK Diesel engine exhaust and some DCA-800SSK STD Operation and Parts Manual REV. #4 06/03/10 DCA-800SSKTABLE of Contents Ordering parts has never been easier Parts Ordering ProceduresDCA-800SSK Specifications DCA-800SSK STD Operation and Parts Manual REV. #4 06/03/10 DCA-800SSK Dimensions TOP and Side DCA-800SSK- Dimensions Front , Rear and Doors Injury to yourself and others DCA-800SSK Safety Message Alert SymbolsThis generator, other property DCA-800SSK Safety Message Alert SymbolsDCA-800SSK Rules for Safe Operation General SafetyBurns DCA-800SSK Rules for Safe Operation Electrical SafetyGenerator Grounding Battery Safety Maintenance SafetyUse the following guidelines when handling the battery Use well insulated gloves when picking up the batteryEmergencies Towing & Transporting SafetyTypical Generator Grounding Application DCA-800SSK InstallationOutdoor Installation DCA-800SSK InstallationMounting DCA-800SSK -TOWING Rules for Safe Operation Towing Safety PrecautionsExplanation of Chart DCA-800SSK -TRAILER-SAFETY GuidelinesCoupler Type of hitch used on the trailer for towing Trailer Specifications DCA-800SSK -TRAILER-SPECIFICATIONSSpecifications DCA-800SSK -TRAILER-SPECIFICATIONSMachine Safety Decals DCA-800SSK Operation and Safety DecalsDCA-800SSK Operation and Safety Decals DCA-800SSK Operation and Safety Decals DCA-800SSK Operation and Safety Decals DCA-800SSK General Information Generator Major Components DCA-800SSK Major ComponentsGenerator Control Panel DCA-800SSK Generator Control PanelDCA-800SSK Generator Control Panel Engine Operating Panels DCA-800SSK Engine Operating PanelFuel Level Gauge -This gauge indicates diesel fuel level DCA-800SSK Engine Operating PanelOutput Terminal Panel Output Terminal Familiarization120VAC Gfci Receptacles DCA-800SSK Output Terminal Panel OverviewMaximum Power Output KW Connecting LoadsDCA-800SSK Output Terminal Panel Overview Over Current RelayThree Phase Load Single Phase LoadDCA-800SSK- Load Application Voltage Change-Over Board Generator OutputVoltagesGenerator Amperage DCA-800SSK Generator OUTPUTS/GAUGE Reading How to Read the OutputTerminal GaugeMaximum Amps Uvwo Terminal Output Voltages DCA-800SSK Output Terminal Panel Connections3Ø-240V Uvwo Terminal Output Voltages 1Ø-240V Uvwo Terminal Output Voltages3Ø-480V Uvwo Terminal Output Voltages DCA-800SSK Output Terminal Panel Connections1Ø-480V Uvwo Terminal Output Voltages 1Ø-277V Uvwo Terminal Output VoltagesCircuit Breakers DCA-800SSK PRE-SETUPLubrication Oil Fuel CheckRefueling Refilling ProceduresFuel from the secondary inner Full Trailer Tank Cleaning the Radiator DCA-800SSK- PRE-SETUPAir Cleaner Fan Belt Tension Operation Freezing WeatherBattery Cable Installation BatteryWiring AlternatorBefore Starting DCA-800SSK GEN. START-UP Procedure ManualEngines exhaust contains harmful emissions If applicable perform the followingHigh position DCA-800SSK Generator START-UP Procedure ManualOil Pressure Gauge Thru 19 pages Place the engine speed switch in the LOW position FigureStarting Auto Mode DCA-800SSK Generator SHUT-DOWN Procedure AutoSet the engine speed switch to the High position To shutdown the generator use the following procedure DCA-600SSK Generator SHUT-DOWN ProcedureEmergency Shutdown Procedure Engine Shutdown Controller S/N 3698617~Inspection / Maintenance DCA-800SSK MaintenanceService Daily Air CleanerCleaning the Fuel Strainer General InspectionChanging Oil Flushing Out Radiator and Changing CoolantReplacing Fuel Filter Greasing Cleaning Breather ElementGenerator Storage Removal From Long Term StorageBattery Charger/Jacket Water Heater Power Connections Air Brake System BrakesCam Brakes Brake Drums or discs, Linings, and HosesTires/Wheels/Lug Nuts DCA-800SSK -TRAILER MaintenanceTire Wear/Inflation SuspensionStart all wheel lug nuts by hand Lug NutTorque RequirementsLug nuts Trailer Wiring Diagram 5-Pin DCA-800SSK -TRAILER-WIRING DiagramDCA-800SSK -TRAILER-WIRING Diagram Generator Wiring Diagram DCA-800SSK Generator Wiring DiagramMain Circuit Breaker Wiring Diagram DCA-800SSK Generator Wiring Diagram Main BreakerEngine Wiring Diagram DCA-800SSK Engine Wiring DiagramDCA-800SSK Engine Wiring Diagram Electronic Governor Controller DCA-800SSK Electronic GOV. Controller Wiring DiagramStarter does not run Engine does not startEngine revolution is not DCA-800SSK -TROUBLESHOOTING EngineSmooth Deficient outputGenerator Troubleshooting DCA-800SSK -TROUBLESHOOTING GENERATOR/ENGINEEngine Controller Troubleshooting Mpec DCA-800SSK -TROUBLESHOOTING MpecQTY. Column Explanation of Code in Remarks ColumnQty Description DCA-800SSK Suggested Spare PartsTo S/N 3706721~DCA-800SSK Generator Assy 0601842366 C51100001028171020004 8171020504DCA-800SSK Generator Assy C4137000003 C51530000020012110075 0042610000DCA-800SSK Control Panel Assy DCA-800SSK Control Panel Assy DCA-800SSK Control BOX Assy C52140100502 C52140000020601806166 CW040LM 1500/5ADCA-800SSK Control BOX Assy Upto S/N 06018237570601823143 0601827655DCA-800SSK Engine and Radiator Assy 3700268~ C59242000246002111231 6003117111DCA-800SSK Engine and Radiator Assy DCA-800SSK Engine and Radiator Assy DCA-800SSK OIL Drain Assy HEX. Head Bolt DCA-800SSK Engine Operating Panel Assy Support LEG DCA-800SSK Outputterminal Assy 7521860504 C52317000037521850504 0010112040DCA-800SSK Outputterminal Assy DCA-800SSK Outputterminal Assy DCA-800SSK Battery Assy 0805018904 01687190520805006404 0805006504DCA-800SSK Muffler Assy 0019112030 C5331100002C5335200104 C5335200204DCA-800SSK Fueltank Assy 0605505030 C53640003030601850590 0810105400Enclosure #1 Assy DCA-800SSK Enclosure #1 Assy7525116004 C54140000020019110030 C5414100004DCA-800SSK Enclosure #1 Assy C5424200203 C5424200103C5434000002 0010120075Enclosure #2 Assy DCA-800SSK Enclosure #2 AssyC5494300104 C54440003137525151004 C5444000203DCA-800SSK Enclosure #2 Assy 0805011204 0805011304M9110100204 0845045004Enclosure #3 Assy DCA-800SSK Enclosure #3 AssyC5494400004 C5454100003C5454100103 C5494400104DCA-800SSK Enclosure #3 Assy 7525966704 75251767040825007362 0845046904DCA-800SSK Rubber Seals Assy 0228900995 02289016900228901035 0228901090DCA-800SSK Name Plate and Decals AT-202 08005209042438 0800520814DCA-800SSK Name Plate and Decals OIL Drain Group Freight Policy Terms and Conditions of Sale PartsDCA-800SSK STD Operation and Parts Manual REV. #4 06/03/10 HERE’S HOW to GET Help

DCA-800SSK specifications

The Multiquip DCA-800SSK is a versatile and powerful generator designed for both commercial and residential applications. Renowned for its reliability and performance, this model is ideal for construction sites, events, and emergency power needs. One of its standout features is the robust 8000-watt output, which makes it suitable for running heavy-duty equipment, tools, and multiple appliances simultaneously.

At the heart of the DCA-800SSK is a reliable Honda engine, renowned for its durability and efficiency. This 4-stroke, air-cooled engine not only provides exceptional power but also boasts lower emissions, making it an environmentally friendly choice. The generator’s fuel tank capacity supports extended run times, ensuring that users can rely on it for prolonged periods without frequent refueling interruptions.

In terms of design, the Multiquip DCA-800SSK has a compact and sturdy frame that allows for easy transport and setup. With its rugged wheels and ergonomic handles, maneuvering the generator across job sites or in emergency situations is a breeze. Additionally, this model is equipped with an electric start feature, providing user convenience and saving time in critical situations.

The DCA-800SSK incorporates advanced technologies such as automatic voltage regulation (AVR), which ensures stable power delivery. This feature is crucial for protecting sensitive electronic devices from voltage fluctuations, making the generator suitable for a variety of applications, including powering computers, medical equipment, and other electronics.

Safety is also prioritized in the design of the DCA-800SSK. It comes with features like low-oil shutoff and overload protection, which prevent damage to both the generator and connected equipment.

With a noise level rated at a manageable decibel level, this generator is suitable for use in noise-sensitive environments. Overall, the Multiquip DCA-800SSK stands out for its combination of power, efficiency, and user-friendly features, making it a reliable choice for anyone in need of backup or portable power solutions. The brand’s reputation for quality and performance adds a layer of trust for users seeking dependable power sources in various settings.