Multiquip DCA-800SSK operation manual Towing & Transporting Safety, Emergencies

Page 15

DCA-800SSK — RULES FOR SAFE OPERATION

Towing & Transporting Safety

To reduce the possibility of an accident while transporting the generator on public roads, always make sure the trailer that supports the generator and the towing vehicle are in good operating condition and both units are mechanically sound.

The following list of safety precautions should be followed when towing your generator:

CAUTION - FOLLOWTOWING REGULATIONS

Check with your local county or state safety towing regulations, in addition to meeting Department of Transportation (DOT) SafetyTowing Regulations, before towing your generator.

ALWAYS shutdown engine before transporting.

Tighten both fuel tank caps securely.

If generator is mounted on a trailer, make sure trailer complies with all local and state safety transportation laws. Follow the listed Towing & Transporting Safety guidelines for basic towing techniques.

Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer "gross vehicle weight rating.”

ALWAYS inspect the hitch and coupling for wear. NEVER tow a trailer with defective hitches, couplings, chains etc.

Check the tire air pressure on both towing vehicle and trailer. Trailer tires should be inflated to 50 psi cold. Also check the tire tread wear on both vehicles.

ALWAYS make sure the trailer is equipped with a "Safety Chain".

ALWAYS attach trailer’s safety chains to towing vehicle properly.

ALWAYS make sure the vehicle and trailer directional, backup, brake, and trailer lights are connected and working properly.

DOT Requirements include the following:

Connect and test electric brake operation.

Secure portable power cables in cable tray with tie wraps.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Place chock blocks underneath wheel to prevent rolling, while parked.

Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

Avoid sudden stops and starts.This can cause skidding, or jack-knifing. Smooth, gradual starts and stops will improve towing.

Avoid sharp turns.

Trailer should be adjusted to a level position at all times when towing.

Raise and lock trailer wheel stand in up position when transporting.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Place support blocks underneath the trailer’s bumper to prevent tipping, while parked.

Avoid sharp turns to prevent rolling.

DO NOT transport generator with fuel in tank.

Emergencies

ALWAYS know the location of the nearest fire extinguisher.

ALWAYS know the location of the nearest and first aid kit.

ALWAYS know the location of the nearest phone or keep a phone on the job site, in case of emergencies.

ALWAYS have easy access to the phone numbers of the nearest Ambulance, Doctor and Fire Department. This information will be invaluable in the case of an emergency.

DCA-800SSK (STD) — OPERATION AND PARTS MANUAL — REV. #4 (06/03/10) — PAGE 15

Image 15
Contents Model DCA-800SSK Diesel engine exhaust and some DCA-800SSK STD Operation and Parts Manual REV. #4 06/03/10 DCA-800SSKTABLE of Contents Ordering parts has never been easier Parts Ordering ProceduresDCA-800SSK Specifications DCA-800SSK STD Operation and Parts Manual REV. #4 06/03/10 DCA-800SSK Dimensions TOP and Side DCA-800SSK- Dimensions Front , Rear and Doors Injury to yourself and others DCA-800SSK Safety Message Alert SymbolsThis generator, other property DCA-800SSK Safety Message Alert SymbolsGeneral Safety DCA-800SSK Rules for Safe OperationBurns Electrical Safety DCA-800SSK Rules for Safe OperationGenerator Grounding Use well insulated gloves when picking up the battery Maintenance SafetyBattery Safety Use the following guidelines when handling the batteryEmergencies Towing & Transporting SafetyTypical Generator Grounding Application DCA-800SSK InstallationDCA-800SSK Installation Outdoor InstallationMounting DCA-800SSK -TOWING Rules for Safe Operation Towing Safety PrecautionsDCA-800SSK -TRAILER-SAFETY Guidelines Explanation of ChartCoupler Type of hitch used on the trailer for towing Trailer Specifications DCA-800SSK -TRAILER-SPECIFICATIONSSpecifications DCA-800SSK -TRAILER-SPECIFICATIONSMachine Safety Decals DCA-800SSK Operation and Safety DecalsDCA-800SSK Operation and Safety Decals DCA-800SSK Operation and Safety Decals DCA-800SSK Operation and Safety Decals DCA-800SSK General Information Generator Major Components DCA-800SSK Major ComponentsGenerator Control Panel DCA-800SSK Generator Control PanelDCA-800SSK Generator Control Panel Engine Operating Panels DCA-800SSK Engine Operating PanelFuel Level Gauge -This gauge indicates diesel fuel level DCA-800SSK Engine Operating PanelOutput Terminal Panel Output Terminal Familiarization120VAC Gfci Receptacles DCA-800SSK Output Terminal Panel OverviewOver Current Relay Connecting LoadsMaximum Power Output KW DCA-800SSK Output Terminal Panel OverviewSingle Phase Load Three Phase LoadDCA-800SSK- Load Application Generator OutputVoltages Voltage Change-Over BoardGenerator Amperage How to Read the OutputTerminal Gauge DCA-800SSK Generator OUTPUTS/GAUGE ReadingMaximum Amps 1Ø-240V Uvwo Terminal Output Voltages DCA-800SSK Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø-240V Uvwo Terminal Output Voltages1Ø-277V Uvwo Terminal Output Voltages DCA-800SSK Output Terminal Panel Connections3Ø-480V Uvwo Terminal Output Voltages 1Ø-480V Uvwo Terminal Output VoltagesFuel Check DCA-800SSK PRE-SETUPCircuit Breakers Lubrication OilRefilling Procedures RefuelingFuel from the secondary inner Full Trailer Tank Operation Freezing Weather DCA-800SSK- PRE-SETUPCleaning the Radiator Air Cleaner Fan Belt TensionAlternator BatteryBattery Cable Installation WiringIf applicable perform the following DCA-800SSK GEN. START-UP Procedure ManualBefore Starting Engines exhaust contains harmful emissionsHigh position DCA-800SSK Generator START-UP Procedure ManualOil Pressure Gauge Thru 19 pages Place the engine speed switch in the LOW position FigureDCA-800SSK Generator SHUT-DOWN Procedure Auto Starting Auto ModeSet the engine speed switch to the High position Engine Shutdown Controller S/N 3698617~ DCA-600SSK Generator SHUT-DOWN ProcedureTo shutdown the generator use the following procedure Emergency Shutdown ProcedureInspection / Maintenance DCA-800SSK MaintenanceGeneral Inspection Air CleanerService Daily Cleaning the Fuel StrainerFlushing Out Radiator and Changing Coolant Changing OilReplacing Fuel Filter Removal From Long Term Storage Cleaning Breather ElementGreasing Generator StorageBattery Charger/Jacket Water Heater Power Connections Brake Drums or discs, Linings, and Hoses BrakesAir Brake System Cam BrakesSuspension DCA-800SSK -TRAILER MaintenanceTires/Wheels/Lug Nuts Tire Wear/InflationLug NutTorque Requirements Start all wheel lug nuts by handLug nuts Trailer Wiring Diagram 5-Pin DCA-800SSK -TRAILER-WIRING DiagramDCA-800SSK -TRAILER-WIRING Diagram Generator Wiring Diagram DCA-800SSK Generator Wiring DiagramMain Circuit Breaker Wiring Diagram DCA-800SSK Generator Wiring Diagram Main BreakerEngine Wiring Diagram DCA-800SSK Engine Wiring DiagramDCA-800SSK Engine Wiring Diagram Electronic Governor Controller DCA-800SSK Electronic GOV. Controller Wiring DiagramStarter does not run Engine does not startDeficient output DCA-800SSK -TROUBLESHOOTING EngineEngine revolution is not SmoothGenerator Troubleshooting DCA-800SSK -TROUBLESHOOTING GENERATOR/ENGINEEngine Controller Troubleshooting Mpec DCA-800SSK -TROUBLESHOOTING MpecQTY. Column Explanation of Code in Remarks Column3706721~ DCA-800SSK Suggested Spare PartsQty Description To S/NDCA-800SSK Generator Assy 8171020504 C51100001020601842366 8171020004DCA-800SSK Generator Assy 0042610000 C5153000002C4137000003 0012110075DCA-800SSK Control Panel Assy DCA-800SSK Control Panel Assy DCA-800SSK Control BOX Assy CW040LM 1500/5A C5214000002C52140100502 0601806166DCA-800SSK Control BOX Assy 0601827655 0601823757Upto S/N 0601823143DCA-800SSK Engine and Radiator Assy 6003117111 C59242000243700268~ 6002111231DCA-800SSK Engine and Radiator Assy DCA-800SSK Engine and Radiator Assy DCA-800SSK OIL Drain Assy HEX. Head Bolt DCA-800SSK Engine Operating Panel Assy Support LEG DCA-800SSK Outputterminal Assy 0010112040 C52317000037521860504 7521850504DCA-800SSK Outputterminal Assy DCA-800SSK Outputterminal Assy DCA-800SSK Battery Assy 0805006504 01687190520805018904 0805006404DCA-800SSK Muffler Assy C5335200204 C53311000020019112030 C5335200104DCA-800SSK Fueltank Assy 0810105400 C53640003030605505030 0601850590Enclosure #1 Assy DCA-800SSK Enclosure #1 AssyC5414100004 C54140000027525116004 0019110030DCA-800SSK Enclosure #1 Assy 0010120075 C5424200103C5424200203 C5434000002Enclosure #2 Assy DCA-800SSK Enclosure #2 AssyC5444000203 C5444000313C5494300104 7525151004DCA-800SSK Enclosure #2 Assy 0845045004 08050113040805011204 M9110100204Enclosure #3 Assy DCA-800SSK Enclosure #3 AssyC5494400104 C5454100003C5494400004 C5454100103DCA-800SSK Enclosure #3 Assy 0845046904 75251767047525966704 0825007362DCA-800SSK Rubber Seals Assy 0228901090 02289016900228900995 0228901035DCA-800SSK Name Plate and Decals 0800520814 0800520904AT-202 2438DCA-800SSK Name Plate and Decals OIL Drain Group Freight Policy Terms and Conditions of Sale PartsDCA-800SSK STD Operation and Parts Manual REV. #4 06/03/10 HERE’S HOW to GET Help

DCA-800SSK specifications

The Multiquip DCA-800SSK is a versatile and powerful generator designed for both commercial and residential applications. Renowned for its reliability and performance, this model is ideal for construction sites, events, and emergency power needs. One of its standout features is the robust 8000-watt output, which makes it suitable for running heavy-duty equipment, tools, and multiple appliances simultaneously.

At the heart of the DCA-800SSK is a reliable Honda engine, renowned for its durability and efficiency. This 4-stroke, air-cooled engine not only provides exceptional power but also boasts lower emissions, making it an environmentally friendly choice. The generator’s fuel tank capacity supports extended run times, ensuring that users can rely on it for prolonged periods without frequent refueling interruptions.

In terms of design, the Multiquip DCA-800SSK has a compact and sturdy frame that allows for easy transport and setup. With its rugged wheels and ergonomic handles, maneuvering the generator across job sites or in emergency situations is a breeze. Additionally, this model is equipped with an electric start feature, providing user convenience and saving time in critical situations.

The DCA-800SSK incorporates advanced technologies such as automatic voltage regulation (AVR), which ensures stable power delivery. This feature is crucial for protecting sensitive electronic devices from voltage fluctuations, making the generator suitable for a variety of applications, including powering computers, medical equipment, and other electronics.

Safety is also prioritized in the design of the DCA-800SSK. It comes with features like low-oil shutoff and overload protection, which prevent damage to both the generator and connected equipment.

With a noise level rated at a manageable decibel level, this generator is suitable for use in noise-sensitive environments. Overall, the Multiquip DCA-800SSK stands out for its combination of power, efficiency, and user-friendly features, making it a reliable choice for anyone in need of backup or portable power solutions. The brand’s reputation for quality and performance adds a layer of trust for users seeking dependable power sources in various settings.