Maintenance

Check Oil Level

Check the crankcase oil level prior to each use, or when the fuel tank is filled. Insufficient oil may cause severe damage to the engine. Make sure the generator is level. The oil level must be between the two notches on the dipstick as shown in Figure 28.

Replacing Oil Filter

„„Remove the old oil filter.

„„Apply a film of oil to the gasket on the new oil filter. „„Install the new oil filter.

„„After the oil cartridge has been replaced, the engine oil will drop slightly. Run the engine for a while and check for leaks before adding more oil if needed. Clean excessive oil from engine.

Flushing Out Radiator and Replacing Coolant

„„Open both cocks located at the crankcase side and at the lower part of the radiator and drain coolant. Open the radiator cap while draining. Remove the overflow tank and drain.

„„Check hoses for softening and kinks. Check clamps for signs of leakage.

„„Tighten both cocks and replace the overflow tank.

„„Replace with coolant as recommended by the engine manufacturer.

„„Close radiator cap tightly.

„„Flush the radiator by running clean tap water through radiator until signs of rust and dirt are removed. DO NOT clean radiator core with any objects, such as a screwdriver.

WARNING

Allow engine to cool when flushing out radiator. Flushing the radiator while hot could cause serious burns from water or steam.

Radiator Cleaning

The radiator (Figure 58) should be sprayed (cleaned) with a high pressure washer when excessive amounts of dirt and debris have accumulated on the cooling fins or tube. When using a high pressure washer, stand at least 5 feet (1.5 meters) away from the radiator to prevent damage to the fins and tube.

Figure 58. Radiator Cleaning

Generator Storage

For long term storage of the generator the following is recommended:

„„Drain the fuel tank completely.Treat with a fuel stabilizer if necessary.

„„Completely drain the oil from the crankcase and refill if necessary with fresh oil.

„„Clean the entire generator, internal and external.

„„Cover the generating set and store in a clean, dry place.

„„Disconnect the battery.

„„Make sure engine coolant is at proper level.

„„If generator is mounted on a trailer, jack trailer up and place on blocks so tires do not touch the ground or block and completely remove the tires.

DCA70USI2 60 hz Generator • operation and parts manual — rev. #0 (06/28/11) — page 39

Image 39
Contents Model dca70USI2 Proposition 65 warning Administrator Reporting Safety DefectsDCA70USI2 Generator Table of ContentsChoose from three easy options SaFeTY meSSageS Safety InformationGeneraTor SaFeTY General SaFeTYEngIne SaFeTY Restricted. If the air fl ow isIf operating in speed ranges above the maximum allowable From fuel vapors or if fuel is spilled on a hot engine FUel SaFeTYToWIng SaFeTY „ never use fuel as a cleaning agentEleCTrICal SaFeTY Grounding SafetyPower Cord/Cable Safety EnvIronmenTal SaFeTY BaTTerY SaFeTYIsuzu BJ-4JJ1XYGD-02 Tier SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationGenerator Grounding Outdoor InstallationIndoor Installation MountingGeneral Information Item no Major ComponentsOFF Generator Control PanelPage Engine Operating Panel Engine Operating Panel Output Terminal Familiarization Terminal legs O and Ground are considered bonded groundsOutput Terminal Panel is provided with the following VAC Gfci Receptacles Removing the Plastic Face Plate Hard Wire Hookup PanelOver Current Relay Connecting LoadsSingle Phase Load Three Phase LoadLoad Application Generator Amperage Voltage Selector SwitchVoltage Selector Switch Locking Button Generator Output VoltagesAC Ammeter Gauge Reading How to Read the ac ammeter and ac voltage gaugesGenerator OUTPUTS/gauge reading AC Voltmeter Gauge ReadingUvwo Terminal Output Voltages 3Ø-240/139 Uvwo Terminal Output Voltages3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages 1Ø-240/120V Uvwo Terminal Output Voltages 3Ø-480/277V Uvwo Terminal Output VoltagesFuel Check Inspection/SETUPCircuit Breakers Lubrication OilOnly use #2 diesel fuel when refueling Refueling ProcedureOperation in Freezing Weather Cleaning the RadiatorAir Cleaner Fan Belt Tension Coolant Antifreeze/Summer Coolant/ WaterAlternator BatteryBattery Cable Installation WiringStarting Manual Place the engine speed switch in the LOW down positionBefore Starting StartingEngine Speed Switch High Automatic Shut-down System Normal Shutdown ProcedureEmergency Shutdown Procedure Place the Mpec Control Switch in the OFF/RESET positionMaintenance General Inspection Air CleanerAir Cleaner with Dust Indicator Fuel Tank Inspection Cleaning Inside the Fuel TankFuel Addition Removing Water from the Fuel TankFlushing Out Radiator and Replacing Coolant Radiator CleaningCheck Oil Level Replacing Oil FilterTrailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Actuator Brake AdjustmentBrakes Hydraulic Surge BrakesTires/Wheels/Lug Nuts Tire Wear/InflationSuspension Never use an pneumatic air gun to tighten wheel lug nuts Lug Nut Torque RequirementsTrailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramEngine Controller Controller Wiring DiagramTroubleshooting Generator Method of Operation Troubleshooting Diagnostic lampExplanation of Code in Remarks Column To 3 units Suggested Spare PartsGenerator Assy B3120100804 B51100004020601820083 0601822664Control box Assy 0330000045 M22130015120330000180 0330000610Control box Assy M2270100204 89701194905825500290 M2213500604Control box Assy M1224100104 06021250900601810141 0601831395Engine and Radiator Assy 0605000451 M29232001348980388560 8980188580Engine and Radiator Assy 001698020 01915006800605515149 M3326200204Output Terminal Assy 0039316000 M3230700003M9220100304 M9220100404Battery Assy 0602220920 0602220199M9310500014 M9103000304Muffler Assy M2333200404 M23301011030017112030 M2333001403Fuel Tank Assy 0605516090 M23630001020605505070 0605501079Enclosure #1 Assy M2423001702 M2413002002M2363300603 0603306797Enclosure ASSY. #1 35C 0041214000 001011404035A 0030014000 35B 0040014000Enclosure 2 Assy M2493305904 M2443001202M2493305103 M2443301803Rubber Seals Assy REMArks Nameplate and Decals Assy M15000220 M1550000204M15000020 M1550002203Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help